Gait analysis in ankle osteoarthritis and total ankle replacement

2007 ◽  
Vol 22 (8) ◽  
pp. 894-904 ◽  
Author(s):  
Victor Valderrabano ◽  
Benno M. Nigg ◽  
Vinzenz von Tscharner ◽  
Darren J. Stefanyshyn ◽  
Beat Goepfert ◽  
...  
2014 ◽  
Vol 20 (3) ◽  
pp. 195-200 ◽  
Author(s):  
Alejandro Roselló Añón ◽  
Ignacio Martinez Garrido ◽  
Juan Cervera Deval ◽  
Daniel Herrero Mediavilla ◽  
María Sánchez González ◽  
...  

2021 ◽  
Vol 10 (11) ◽  
pp. 2258
Author(s):  
Massimiliano Mosca ◽  
Silvio Caravelli ◽  
Emanuele Vocale ◽  
Simone Massimi ◽  
Davide Censoni ◽  
...  

Recently, the progress in techniques and in projecting new prosthetic designs has allowed increasing indications for total ankle replacement (TAR) as treatment for ankle osteoarthritis. This retrospective work comprehended 39 subjects aged between 47 and 79 years old. The patients, observed for at least 12 months (mean follow up of 18.2 ± 4.1 months), have been evaluated according to clinical and radiological parameters, both pre- and post-operatively. The AOFAS and VAS score significantly improved, respectively, from 46.2 ± 4.8 to 93.9 ± 4.1 and from 7.1 ± 1.1 to 0.7 ± 0.5 (p value < 0.05). At the final evaluation, the mean plantarflexion passed from 12.2° ± 2.3° to 18.1° ± 2.4° (p value < 0.05) and dorsiflexion from a pre-operative mean value of 8.7° ± 4.1° to 21.7° ± 5.4° post-operatively (p value < 0.05). This study found that this new total ankle replacement design is a safe and effective procedure for patients effected by end-stage ankle osteoarthritis. Improvements have been demonstrated in terms of range of motion, radiographic parameters and patient-reported outcomes. However, further studies are needed to assess the long-term performance of these prostheses.


1979 ◽  
Vol 61 (7) ◽  
pp. 976-988 ◽  
Author(s):  
J D Demottaz ◽  
J M Mazur ◽  
W H Thomas ◽  
C B Sledge ◽  
S R Simon

2007 ◽  
Vol 28 (2) ◽  
pp. 281-291 ◽  
Author(s):  
Victor Valderrabano ◽  
Benno M. Nigg ◽  
Venzenz von Tscharner ◽  
Cyril B. Frank ◽  
Beat Hintermann

2017 ◽  
Vol 2 (3) ◽  
pp. 2473011417S0002
Author(s):  
Camilla Maccario ◽  
Cristian Indino ◽  
Luigi Manzi ◽  
Federico Giuseppe Usuelli ◽  
Claudia Di Silvestri

Category: Ankle, Ankle Arthritis Introduction/Purpose: Primary ankle osteoarthritis is very uncomon, in fact 70-78% of the case ankle arthritis has a post- traumatic cause. Ankle arthrodesis (AA), has been considered a reliable procedure for resolution of ankle osteoarthritis. Recent modifications in Total ankle replacement (TAR) designs have challenged the perception that AA is the treatment of choice for end-stage ankle arthritis. Trabecular Metal Total Ankle system is a fixed-bearing prosthesis. The new design is flanked by use of new materials. The tibial articular surface is constructed of highly crosslinked UHMWPE and Trabecular Metal lining the talar and the tibial base component. The purpose of this retrospective study was to show the preliminary result in 31 patients underwent to ankle replacement using Zimmer Trabecular Metal Total Ankle system. Methods: We retrospectively assessed prospectively collected data on the initial cohort of 31 patients undergoing TAR with this implant. Clinical evaluation was determined pre and postoperatively for a minimum of 24 months after surgery. Pain was rated using the visual analogue scale (VAS). Functional results were assessed as well as ankle range of motion (ROM). Clinical outcomes used where the Short Form SF-12 Quality of Life score, the American Foot and Ankle Society (AOFAS). The imaging follow-up included ankle radiographs done at 6, 12 and 24 months. Radiological parameters were angles??(normal values 90 +- 2),?? (normal value 85 +- 2),??? normal values 20 +- 2) and TTratio? normal values: 27% to 42%). Results: The study included 31 ankles of TM Ankle Replacement in 31 consecutive patients over a period of 2 years (2013–2015). Out of 31 patients, 13 were females and 18 were males (average age 49.4 years, range, 30–75 years). All procedures were performed by a single surgeon. The ROM plantarflexion and dorsiflexion improved significantly (p <0.001) at the last follow up. The mean VAS pain score decreased significantly from 7.42 points (range 4 – 10 points) preoperatively to 1.42 points (range, 0 - 3 points) at the time of the latest follow-up (p <0.001). AOFAS and SF-12 scores both improved from postoperatively to the last follow up. (Table 1). We noted stable implants based on our radiographic parameters, with no corrections loosening. (Table 2) Conclusion: Our study evaluated the new fixed bearing Zimmer TM total ankle replacement approved by the US FDA in 2012 and is the first studies to evaluate the clinical and radiographic outcomes of this prosthesis. Of 31 ankles treated with a new transfibular arthroplasty system, only two asymptomatic fibular delayed union were registered. No implant failure was noted at 24 months postoperatively. Four ankles underwent secondary surgery for symptomatic fibular hardware with good outcome. The findings suggest that this total ankle system is safe and effective at short-term follow-up.


2019 ◽  
Vol 4 (4) ◽  
pp. 2473011419S0015
Author(s):  
Timothy R. Daniels ◽  
Shahin Kayum ◽  
Ryan M. Khan ◽  
Anastasia Sanjevic

Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus).


2009 ◽  
Vol 29 ◽  
pp. e9-e10
Author(s):  
S. Ingrosso ◽  
M.G. Benedetti ◽  
A. Leardini ◽  
S. Casanelli ◽  
T. Sforza ◽  
...  

2007 ◽  
Vol 28 (3) ◽  
pp. 313-322 ◽  
Author(s):  
H. Cornelis Doets ◽  
Marienke van Middelkoop ◽  
Han Houdijk ◽  
Rob G.H.H. Nelissen ◽  
H.E.J. (Dirkjan) Veeger

2008 ◽  
Vol 98 (1) ◽  
pp. 19-26 ◽  
Author(s):  
Maria Grazia Benedetti ◽  
Alberto Leardini ◽  
Matteo Romagnoli ◽  
Lisa Berti ◽  
Fabio Catani ◽  
...  

Background: Most clinical studies on total ankle replacement (TAR) report assessments based on traditional clinical scores or radiographic analysis. Only a few studies have used modern instrumentation for quantitative functional analysis during the execution of activities of daily living. The aim of this study was to use gait analysis to compare the functional performance of patients who underwent TAR versus a control population. Methods: A retrospective analysis was performed of ten consecutive patients who had undergone meniscal-bearing TAR. Clinical and functional assessments were performed at a mean follow-up of 34 months with a modified Mazur scoring system and state-of-the-art gait analysis. Results: Gait analysis assessment of TAR at medium-term follow-up showed satisfactory results for all patients, with adequate recovery of range of motion. Because the literature reports unsatisfying long-term results, it is important to evaluate these patients over a longer follow-up period. Conclusions: This study showed that TAR yields satisfactory, but not outstanding, general functional results at nearly 3 years’ follow-up. These gait analysis results highlight the importance of integrating in vivo measurements with the standard clinical assessments of patients who underwent TAR while they perform activities of daily living. These results also emphasize the importance of evaluating the functional outcome of TAR over time. (J Am Podiatr Med Assoc 98(1): 19–26, 2008)


Sign in / Sign up

Export Citation Format

Share Document