scholarly journals A simple, anatomically based correction to the conventional ankle joint center

2008 ◽  
Vol 23 (10) ◽  
pp. 1299-1302 ◽  
Author(s):  
Dustin A. Bruening ◽  
Ashlie N. Crewe ◽  
Frank L. Buczek
Keyword(s):  
1998 ◽  
Vol 1 (1) ◽  
pp. 23-39
Author(s):  
Carter J. Kerk ◽  
Don B. Chaffin ◽  
W. Monroe Keyserling

The stability constraints of a two-dimensional static human force exertion capability model (2DHFEC) were evaluated with subjects of varying anthropometry and strength capabilities performing manual exertions. The biomechanical model comprehensively estimated human force exertion capability under sagittally symmetric static conditions using constraints from three classes: stability, joint muscle strength, and coefficient of friction. Experimental results showed the concept of stability must be considered with joint muscle strength capability and coefficient of friction in predicting hand force exertion capability. Information was gained concerning foot modeling parameters as they affect whole-body stability. Findings indicated that stability limits should be placed approximately 37 % the ankle joint center to the posterior-most point of the foot and 130 % the distance from the ankle joint center to the maximal medial protuberance (the ball of the foot). 2DHFEC provided improvements over existing models, especially where horizontal push/pull forces create balance concerns.


2017 ◽  
Vol 2 (3) ◽  
pp. 2473011417S0003
Author(s):  
Daniel Sturnick ◽  
Constantine Demetracopoulos ◽  
Guilherme Honda Saito

Category: Ankle, Ankle Arthritis, Hindfoot Introduction/Purpose: Implant component positioning is considered as an important factor in function and longevity in total ankle arthroplasty (TAA). However, accurate and repeatable positioning remains a limitation with current techniques and instrumentation. In addition, further investigation is needed to objectively define the optimum component positioning. Cadaveric gait simulation is a valuable tool for investigating foot and ankle joint mechanics during functional tasks such as the stance phase of gait. The objective of this study was to investigate the functional axis of rotation of the native ankle joint during simulated gait. Methods: The stance phase of healthy gait was simulated with six mid-tibia cadaveric specimens using a previously validated device and methodology. A robotic platform reproduced tibial-ground kinematics by moving a force plate relative to the stationary specimen while physiologic loads were applied to the extrinsic tendons to actuate the foot. (Figure 1A). Ankle kinematics were measured from reflective markers attached to the tibia and talus via surgical pins. The helical axes of rotation of the talus with respect to the tibia was calculated during three portions of stance: initial plantarflexion during earlier-stance after heal strike, dorsiflexion during mid-stance, and final plantarflexion during late-stance. The position and orientation of these kinematic-defined axes of rotation were compared to the transmalleolar axis and reduced to its anteroposterior position and transverse plane angle (Figure 1B). Results: Analyses revealed that ankle joint functional axis of rotation varied from the anatomic reference throughout stance. The kinematic center of rotation was located 16.4 ± 5.8 mm, 16.5 ± 6.6 mm, and 15.6 ± 6.5 mm anterior to the transmalleolar axis during early-, mid- and late-portions of stance, respectively. Conclusion: This study revealed that the position of the flexion-extension axis varies greatly between specimens during simulated gait. While previous reports have suggested that the transmalleolar axis is an acceptable approximation for the ankle joint center, these findings suggest that further research in warranted to better describe the complex tibiotalar kinematics. This work may provide future insight to guide implant design and advance techniques, to better place articular constraints of a total ankle in the native center of rotation of the joint.


Swiss Surgery ◽  
2003 ◽  
Vol 9 (6) ◽  
pp. 283-288
Author(s):  
Maurer ◽  
Stamenic ◽  
Stouthandel ◽  
Ackermann ◽  
Gonzenbach

Aim of study: To investigate the short- and long-term outcome of patients with isolated lateral malleolar fracture type B treated with a single hemicerclage out of metallic wire or PDS cord. Methods: Over an 8-year period 97 patients were treated with a single hemicerclage for lateral malleolar fracture type B and 89 were amenable to a follow-up after mean 39 months, including interview, clinical examination and X-ray controls. Results: The median operation time was 35 minutes (range 15-85 min). X-ray controls within the first two postoperative days revealed an anatomical restoration of the upper ankle joint in all but one patient. The complication rate was 8%: hematoma (2 patients), wound infection (2), Sudeck's dystrophy (2) and deep vein thrombosis (1). Full weight-bearing was tolerated at median 6.0 weeks (range 2-26 weeks). No secondary displacement, delayed union or consecutive arthrosis of the upper ankle joint was observed. All but one patient had restored symmetric joint mobility. Ninety-seven percent of patients were satisfied or very satisfied with the outcome. Following bone healing, hemicerclage removal was necessary in 19% of osteosyntheses with metallic wire and in none with PDS cord. Conclusion: The single hemicerclage is a novel, simple and reliable osteosynthesis technique for isolated lateral type B malleolar fractures and may be considered as an alternative to the osteosynthesis procedures currently in use.


BMJ ◽  
1951 ◽  
Vol 1 (4721) ◽  
pp. 1494-1494
Author(s):  
J. S. Batchelor
Keyword(s):  

2019 ◽  
Vol 19 (06) ◽  
pp. 1950050
Author(s):  
M. T. KARIMI ◽  
R. B. TAHMASEBI ◽  
B. SATVATI ◽  
F. FATOYE

Flat foot is the most common foot disorder that influences the alignment of the lower limb structure. It is controversial whether the use of foot insole influences kinetic and kinematic of the leg or not. Therefore, this study investigated the influence of foot insole on the gait performance in subjects with flat foot disorder. A group of flat foot subject was recruited into this study (the number of subjects was 15). The motion of the leg joints was determined using the Qualysis motion analysis system. Moreover, the force applied on the lower limb was recorded by a Kistler force plate. The range of motion of the lower limb joints, the moments applied on the lower limb joints and force transmitted through the leg were the parameters used in this study. The difference between these parameters during walking with and without insole was evaluated using the paired [Formula: see text]-test. Significant value was set at [Formula: see text]. There was no significant difference between the range of motion of ankle joint while walking with and without insole. However, the medial directed force applied on the leg decreased significantly [Formula: see text]. The use of foot insole did not influence the moments transmitted through the hip and knee joints. The walking speed of the subjects improved while walking with foot insole. Use of foot insole influenced the magnitude of the force applied on the leg and the adductor moment of ankle joint due to its influence on foot alignment. As the walking speed of the improved subjects follows the use of insole, it can be concluded that it may have a positive effects on the performance of flat foot subjects.


2021 ◽  
Vol 13 (sup1) ◽  
pp. S89-S91
Author(s):  
Sébastien Pavailler ◽  
Nicolas Masson ◽  
Nicolas Horvais
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document