Preparation and evaluation of novel bio-based Bis-GMA-free dental composites with low estrogenic activity

Author(s):  
Yinan Sun ◽  
Zeying Zhou ◽  
Hao Jiang ◽  
Yuting Duan ◽  
Jialin Li ◽  
...  
Author(s):  
B. M. Culbertson ◽  
M. L. Devinev ◽  
E. C. Kao

The service performance of current dental composite materials, such as anterior and posterior restoratives and/or veneer cements, needs to be improved. As part of a comprehensive effort to find ways to improve such materials, we have launched a broad spectrum study of the physicochemical and mechanical properties of photopolymerizable or visible light cured (VLC) dental composites. The commercially available VLC materials being studied are shown in Table 1. A generic or neat resin VLC system is also being characterized by SEM and TEM, to more fully understand formulation variables and their effects on properties.At a recent dental research meeting, we reported on the differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) characterization of the materials in Table 1. It was shown by DSC and DMA that the materials are substantially undercured by commonly used VLC techniques. Post curing in an oral cavity or a dry environment at 37 to 50°C for 7 or more hours substantially enhances the cure of the materials.


1970 ◽  
Vol 23 (02) ◽  
pp. 202-210 ◽  
Author(s):  
R Bishop ◽  
H Ekert ◽  
G Gilchrist ◽  
E Shanbrom ◽  
L Fekete

SummaryA new fibrin plate technic for evaluating components of the fibrinolytic system has been developed. It provides quick, accurate, and easily interpreted results for the fibrinolytic profile. The standardized human plasminogen-free fibrin plates can be produced in bulk and stored for prolonged periods of time. A test specimen placed in a well punched in the buffered agarose gel diffuses into the agar and lyses the fibrin clot, forming a clear reaction zone. The zone diameter is directly proportional to the log of the percent concentration of available fibrinolytic enzyme in the specimen. The plates may be used to quantitate total plasminogen, and estimate available plasmin and active plasmin. A good correlation between results obtained using these fibrin plates and caseinolytic methods was found. Performance and interpretation of tests of fibrinolysis done on these new fibrin plates indicate that it may be the most sensitive technic available for clinical laboratory work.


1960 ◽  
Vol 19 (4) ◽  
pp. 1143-1149 ◽  
Author(s):  
E. M. Bickoff ◽  
A. L. Livingston ◽  
A. N. Booth ◽  
C. R. Thompson ◽  
E. A. Hollowell ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document