scholarly journals Short-circuit model of the DFIG considering coordinated control strategy of grid- and rotor-side converters

2022 ◽  
Vol 8 ◽  
pp. 1046-1055
Author(s):  
Fan Xiao ◽  
Yongjun Xia ◽  
Kanjun Zhang ◽  
Zhe Zhang ◽  
Xianggen Yin
2021 ◽  
Vol 248 ◽  
pp. 02005
Author(s):  
Zhang Zhaopeng ◽  
Suo Dongnan

Based on the analysis of the operation characteristics of the fault of direct-drive permanent magnet wind turbine and the existing protection strategies, in order to improve the low-voltage operation capability of direct-drive permanent magnet wind turbine, a new coordinated control strategy for low-voltage crossing is proposed in this paper, which includes DC brake system control of unloading circuit, double second-order generalized integral phase-locked control, extracting positive and negative sequence of grid voltage and reactive power control on grid side. Based on the common three-phase symmetrical drop fault and asymmetrical fault caused by single grounding short circuit in power grid, PASCAD simulation experiment is conducted to verify the low voltage traversing ability of wind turbine.


Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 28 ◽  
Author(s):  
Bo Pang ◽  
Hui Dai ◽  
Feng Li ◽  
Heng Nian

For improving the performance of a doubly fed induction generator (DFIG) system under a harmonically distorted grid, this paper proposes a coordinated control strategy which is effective for grid inter-harmonics as well as grid integer harmonics. In order to suppress the negative impacts caused by grid harmonics, including inter-harmonics, this paper introduces an additional harmonics suppression controller, which contains a Chebyshev high-pass filter and a modified lead element considering the delay compensation. The proposed controller is employed in the rotor side converter (RSC) and grid side converter (GSC). Based on the proposed harmonics suppression controller, a coordinated control strategy between RSC and GSC is developed, in which the control targets, including the sinusoidal output current, constant power, or steady generator torque, can be achieved for DFIG, while GSC is responsible for maintaining the sinusoidal total current to guarantee the power quality of the grid connection. The effectiveness of the proposed method is verified by the theoretical analysis, and the experimental results derived using a 1 kW DFIG system validate the correctness of the theoretical analysis.


IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 84506-84515
Author(s):  
Sungyoon Song ◽  
Sungchul Hwang ◽  
Gilsoo Jang ◽  
Minhan Yoon

Sign in / Sign up

Export Citation Format

Share Document