scholarly journals In-Situ Monitoring of Local Corrosion Process of Scratched Epoxy Coated Carbon Steel in Simulated Pore Solution Containing Varying percentage of Chloride ions by Localized Electrochemical Impedance Spectroscopy

2016 ◽  
Vol 199 ◽  
pp. 305-313 ◽  
Author(s):  
T. Balusamy ◽  
T. Nishimura
Coatings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 113
Author(s):  
Jacob Ress ◽  
Ulises Martin ◽  
Juan Bosch ◽  
David M. Bastidas

The protection of mild steel by modified epoxy coating containing colophony microencapsulated corrosion inhibitors was investigated in this study. The corrosion behavior of these epoxy coatings containing colophony microcapsules was studied by electrochemical analysis using cyclic potentiodynamic polarization and electrochemical impedance spectroscopy. The microcapsule coating showed decreased corrosion current densities of 2.75 × 10−8 and 3.21 × 10−8 A/cm2 along with corrosion potential values of 0.349 and 0.392 VSCE for simulated concrete pore solution and deionized water with 3.5 wt.% NaCl, respectively, indicating improved corrosion protection in both alkaline and neutral pH. Electrochemical impedance spectroscopy analysis also showed charge transfer resistance values over one order of magnitude higher than the control sample, corroborating the electrochemical corrosion potential and current density testing results. Overall, the use of colophony microcapsules showed improved corrosion protection in simulated concrete pore solution and DI water solutions containing chloride ions.


2013 ◽  
Vol 652-654 ◽  
pp. 1432-1435
Author(s):  
Qian Hu ◽  
Jing Liu ◽  
Jie Zhang ◽  
Feng Huang ◽  
Xing Peng Guo

The crevice corrosion behaviors of X52 carbon steel in two typical Cl--containing solutions were investigated by electrochemical noise and electrochemical impedance spectroscopy. Results show that oxygen concentration difference leads to the coupled current in NaCl + NaHCO3 solution while HAc concentration difference causes the coupled current in NaCl solution saturated with CO2 in the presence of HAc. There exists an apparent incubation stage during the crevice corrosion process of X52 carbon steel in the former. However, no obvious incubation period of crevice corrosion can be observed in the latter. Micrography shows that the crevice corrosion occurs indeed and the corrosion inside the crevice is not uniform.


2019 ◽  
Author(s):  
marijn blommaert ◽  
david vermaas ◽  
boaz izelaar ◽  
ben in't veen ◽  
wilson smith

Using electrochemical impedance spectroscopy (EIS), we observed the rate of water dissociation decrease in the presence of salt ions while also observing the diffusion and migration of these salt ions, showing a clear link between the peaks observed in EIS and ion crossover. In addition, we show how EIS can be used to in-situ monitor the stability and ageing of a BPM, revealing that degradation of the BPM is more prominent in extreme pH electrolyte pairs compared to non-extreme electrolyte pairs. The in-situ monitoring of the WDR and stability of a BPM are vital methods for adequate and consistent comparison of novel designs of BPM-based systems, where EIS allows for discriminating BPM characteristics from other components even during operation. <br>


Sign in / Sign up

Export Citation Format