Design procedure to bearing concrete failure in concrete-filled steel tube columns with bolted shear connectors

2021 ◽  
Vol 232 ◽  
pp. 111910
Author(s):  
Lucas Ribeiro dos Santos ◽  
Rodrigo Barreto Caldas ◽  
Lucas Figueiredo Grilo ◽  
Hermes Carvalho ◽  
Ricardo Hallal Fakury
2021 ◽  
Vol 53 (3) ◽  
pp. 210301
Author(s):  
Ahmed Najm Abdullah ◽  
Bambang Budiono ◽  
Herlien Dwiarti Setio ◽  
Erwin Lim

Previous studies on the connection between concrete-filled steel tube (CFST) columns and reinforced concrete (RC) beams have shown a loss of joint confinement because the steel tube was completely or partially cut in the joint area. This research presents a new connection system that provides joint confinement through a continuous steel tube. Potential sliding shear at the smooth interface between the columns and beams in the joint face is mitigated using two mechanisms: (i) shear connectors and (ii) longitudinal web beam reinforcement. This study tested two CFST column and RC beam joints to 4.5% drift ratio under combined compression axial load and lateral cyclic load. The experimental results revealed no cracks at the joint zone and the specimens satisfied the ACI 374.1-05 criteria, despite minor sliding at the beam-column interface. The finite element (FE) model showed good agreement with the experimental results.


2017 ◽  
Vol 7 (8) ◽  
pp. 818 ◽  
Author(s):  
Qiyun Qiao ◽  
Wenwen Zhang ◽  
Zhiwei Qian ◽  
Wanlin Cao ◽  
Wenchao Liu

Structures ◽  
2021 ◽  
Vol 33 ◽  
pp. 1853-1867
Author(s):  
Yong Ye ◽  
Yang Liu ◽  
Zi-Xiong Guo ◽  
Rachel Chicchi

2021 ◽  
pp. 136943322110093
Author(s):  
Zhenzhen Liu ◽  
Yiyan Lu ◽  
Shan Li ◽  
Jiancong Liao

A comprehensive study of the shear characteristics of steel fiber reinforced recycled concrete-filled steel tube (SRCFST) columns is conducted. 50 CFST stub columns are tested with the variables of steel tube diameter-thickness ratio ( D/t), shear span-to-depth ratio (λ), axial compression ratio ( n), and concrete mix. Two types of cements, three recycled aggregate percentages, three water-cement ratios, and three steel fiber contents are considered in design of concrete mixes. The experimental results show that SRCFST columns present the coincident shear behavior of the ordinary CFST columns. As λ is increased, shear resistance shows a downtrend, while the flexural strength presents an increasing trend. Imposing axial compression or thickening steel tube contributes to an adequate safety margin in plastic period. Based on the contributions superposition method, a predicted model of the shear capacity of SRCFST columns is proposed in consideration of shear-span ratio, axial compression, and self-stress.


Structures ◽  
2021 ◽  
Vol 31 ◽  
pp. 558-575
Author(s):  
Yu-Hang Wang ◽  
Yu-Yan Wang ◽  
Xu-Hong Zhou ◽  
Ran Deng ◽  
Yong-Sen Lan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document