Enhanced Safety and Performance of High-Voltage Solid-State Sodium Battery through Trilayer, Multifunctional Electrolyte Design

Author(s):  
Lingbing Ran ◽  
Ming Li ◽  
Emily Cooper ◽  
Bin Luo ◽  
Ian Gentle ◽  
...  
2014 ◽  
Vol 703 ◽  
pp. 33-40
Author(s):  
N. Hassan ◽  
A. Sanusi ◽  
Azizah Hanom Ahmad

A Na–ion conducting solid electrolyte system was prepared by using ball milling and sintering method. The electrical conductivity study was carried out as a function of NaI concentration by Electrical Impedance Spectroscopy technique and the maximum conductivity of (1.02±0.19)×10-4S cm−1at room temperature was obtained for the composition 0.50 NaI:0.50 Na3PO4. Further characterization was performed by using and Infrared (FTIR) technique. From FTIR spectra, the variation in the peak intensity and shifting is observed due to the presence of P–O and PO43−bands that had been shifted indicating changes in polyhedral structure which in turn led to the formation of conducting channel by corner sharing or through edges. The ionic transference number was found in the value of 0.92 which suggests that ions are the charge carriers. The optimum composition with the highest conductivity of the sample considered as a good candidate to be used as solid electrolyte in solid state sodium battery. The sodium battery with configuration: Na/NaI–Na3PO4/V2O4was tested by the discharged characteristic at a current of 1.0 μA. The solid state sodium batteries exhibited a discharge capacity of 144mAh/g.


2021 ◽  
Vol 13 (10) ◽  
pp. 11958-11967
Author(s):  
Zhongran Yao ◽  
Kongjun Zhu ◽  
Xia Li ◽  
Jie Zhang ◽  
Jun Li ◽  
...  

Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1204
Author(s):  
Gul Ahmad Ludin ◽  
Mohammad Amin Amin ◽  
Hidehito Matayoshi ◽  
Shriram S. Rangarajan ◽  
Ashraf M. Hemeida ◽  
...  

This paper proposes a new and surge-less solid-state direct current (DC) circuit breaker in a high-voltage direct current (HVDC) transmission system to clear the short-circuit fault. The main purpose is the fast interruption and surge-voltage and over-current suppression capability analysis of the breaker during the fault. The breaker is equipped with series insulated-gate bipolar transistor (IGBT) switches to mitigate the stress of high voltage on the switches. Instead of conventional metal oxide varistor (MOV), the resistance–capacitance freewheeling diodes branch is used to bypass the high fault current and repress the over-voltage across the circuit breaker. The topology and different operation modes of the proposed breaker are discussed. In addition, to verify the effectiveness of the proposed circuit breaker, it is compared with two other types of surge-less solid-state DC circuit breakers in terms of surge-voltage and over-current suppression. For this purpose, MATLAB Simulink simulation software is used. The system is designed for the transmission of 20 MW power over a 120 km distance where the voltage of the transmission line is 220 kV. The results show that the fault current is interrupted in a very short time and the surge-voltage and over-current across the proposed breaker are considerably reduced compared to other topologies.


2021 ◽  
Author(s):  
Gabriele Lingua ◽  
Patrick Grysan ◽  
Petr S. Vlasov ◽  
Pierre Verge ◽  
Alexander S. Shaplov ◽  
...  

2021 ◽  
Vol 38 ◽  
pp. 489-498
Author(s):  
Ta-Chung Liu ◽  
Sutarsis Sutarsis ◽  
Xin-Yan Zhong ◽  
Wei-Chen Lin ◽  
Syun-Hong Chou ◽  
...  
Keyword(s):  

2021 ◽  
pp. 2100836
Author(s):  
Shumin Zhang ◽  
Feipeng Zhao ◽  
Shuo Wang ◽  
Jianwen Liang ◽  
Jian Wang ◽  
...  

1950 ◽  
Vol 1950 (7) ◽  
pp. 191-193
Author(s):  
H.F. Jones ◽  
C.J.O. Garrard

Sign in / Sign up

Export Citation Format

Share Document