electrical impedance spectroscopy
Recently Published Documents


TOTAL DOCUMENTS

735
(FIVE YEARS 239)

H-INDEX

38
(FIVE YEARS 7)

Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 461
Author(s):  
Paula Navarro ◽  
Alberto Olmo ◽  
Mercè Giner ◽  
Marleny Rodríguez-Albelo ◽  
Ángel Rodríguez ◽  
...  

The chemical composition and surface topography of titanium implants are essential to improve implant osseointegration. The present work studies a non-invasive alternative of electrical impedance spectroscopy for the characterization of the macroporosity inherent to the manufacturing process and the effect of the surface treatment with femtosecond laser of titanium discs. Osteoblasts cell culture growths on the titanium surfaces of the laser-treated discs were also studied with this method. The measurements obtained showed that the femtosecond laser treatment of the samples and cell culture produced a significant increase (around 50%) in the absolute value of the electrical impedance module, which could be characterized in a wide range of frequencies (being more relevant at 500 MHz). Results have revealed the potential of this measurement technique, in terms of advantages, in comparison to tiresome and expensive techniques, allowing semi-quantitatively relating impedance measurements to porosity content, as well as detecting the effect of surface modification, generated by laser treatment and cell culture.


Sensor Review ◽  
2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Alex Mason ◽  
Dmytro Romanov ◽  
L. Eduardo Cordova-Lopez ◽  
Steven Ross ◽  
Olga Korostynska

Purpose Modern meat processing requires automation and robotisation to remain sustainable and adapt to future challenges, including those brought by global infection events. Automation of all or many processes is seen as the way forward, with robots performing various tasks instead of people. Meat cutting is one of these tasks. Smart novel solutions, including smart knives, are required, with the smart knife being able to analyse and predict the meat it cuts. This paper aims to review technologies with the potential to be used as a so-called “smart knife” The criteria for a smart knife are also defined. Design/methodology/approach This paper reviews various technologies that can be used, either alone or in combination, for developing a future smart knife for robotic meat cutting, with possibilities for their integration into automatic meat processing. Optical methods, Near Infra-Red spectroscopy, electrical impedance spectroscopy, force sensing and electromagnetic wave-based sensing approaches are assessed against the defined criteria for a smart knife. Findings Optical methods are well established for meat quality and composition characterisation but lack speed and robustness for real-time use as part of a cutting tool. Combining these methods with artificial intelligence (AI) could improve the performance. Methods, such as electrical impedance measurements and rapid evaporative ionisation mass spectrometry, are invasive and not suitable in meat processing since they damage the meat. One attractive option is using athermal electromagnetic waves, although no commercially developed solutions exist that are readily adaptable to produce a smart knife with proven functionality, robustness or reliability. Originality/value This paper critically reviews and assesses a range of sensing technologies with very specific requirements: to be compatible with robotic assisted cutting in the meat industry. The concept of a smart knife that can benefit from these technologies to provide a real-time “feeling feedback” to the robot is at the centre of the discussion.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 170
Author(s):  
Balen K. Faris ◽  
Ary A. Hassan ◽  
Shujahadeen B. Aziz ◽  
Mohamad A. Brza ◽  
Aziz M. Abdullah ◽  
...  

The polymer electrolyte system of methylcellulose (MC) doped with various sodium bromide (NaBr) salt concentrations is prepared in this study using the solution cast technique. FTIR and XRD were used to identify the structural changes in solid films. Sharp crystalline peaks appeared at the XRD pattern at 40 and 50 wt.% of NaBr salt. The electrical impedance spectroscopy (EIS) study illustrates that the loading of NaBr increases the electrolyte conductivity at room temperature. The DC conductivity of 6.71 × 10−6 S/cm is obtained for the highest conducting electrolyte. The EIS data are fitted with the electrical equivalent circuit (EEC) to determine the impedance parameters of each film. The EEC modeling helps determine the circuit elements, which is decisive from the engineering perspective. The DC conductivity tendency is further established by dielectric analysis. The EIS spectra analysis shows a decrease in bulk resistance, demonstrating free ion carriers and conductivity boost. The dielectric property and relaxation time confirmed the non-Debye behavior of the electrolyte system. An incomplete semicircle further confirms this behavior model in the Argand plot. The distribution of relaxation times is related to the presence of conducting ions in an amorphous structure. Dielectric properties are improved with the addition of NaBr salt. A high value of a dielectric constant is seen at the low frequency region.


2021 ◽  
Vol 15 (6) ◽  
pp. 061302
Author(s):  
Furkan Gökçe ◽  
Paolo S. Ravaynia ◽  
Mario M. Modena ◽  
Andreas Hierlemann

2021 ◽  
Author(s):  
Chidiebere S. Nnebuo ◽  
Denise Hambsch ◽  
Oded Nir

Mineral fouling is a major hindrance to high recovery effluent nanofiltration, with calcium phosphate (Ca-P) and calcium carbonate (CaCO3) the most prevalent mineral foulants. In this study, we used a novel combination of real-time in-line microscopy, electrical impedance spectroscopy (EIS), post SEM analysis, and filtration metrics (water flux and rejection) to study mineral fouling mechanisms of Ca-P and CaCO3 salts in synthetic effluent nanofiltration. We used nanofiltration (NF) polyelectrolyte multilayer (PEM) membranes, prepared by static layer-by-layer (LbL) coating of a cationic polymer - polydiallyl dimethylammonium chloride, and anionic polymer - poly styrenesulfonate (six bi-layer) on a polyethersulfone (PES) ultrafiltration (UF) membrane. Increasing permeate recovery over filtration time was simulated through additions of CaCl2 with NaHCO3 or NaH2PO4/Na2HPO4. Using the novel combination of methods, we delineated the mechanisms governing fouling development with time for both CaCO3 and Ca-P. For CaCO3, a transition from heterogeneous precipitation on the membrane surface (scaling) to particulate fouling due to bulk precipitation was identified. For Ca-P, a transition from fouling by amorphous particles to fouling by crystalline particles was identified; and this phase-change was captured in real-time images using an in-line microscope. We also found that for similar precipitation potentials measured by weight, Ca-P fouling was more detrimental to water flux (86% decrease) compared to CaCO3 (20% decrease) due to the voluminous amorphous phase. We established in-line microscopy as a new useful method to study mineral fouling, as it gives invaluable information on the suspended particles in real-time. Combining it with EIS gives complementary information on mineral accumulation on the membrane surface. Insight from this study and further use of these methods can guide future strategies towards higher effluent recovery by membrane filtration.


Plant Methods ◽  
2021 ◽  
Vol 17 (1) ◽  
Author(s):  
Yang Liu ◽  
DongMing Li ◽  
Ji Qian ◽  
Bao Di ◽  
Gang Zhang ◽  
...  

AbstractNondestructive testing of plant roots is a hot topic in recent years. The traditional measurement process is time-consuming and laborious, and it is impossible to analyze the state of plant roots without destroying the sample. Recent studies have shown that as an excellent nondestructive measurement method, although electrical impedance spectroscopy (EIS) has made great achievements in many botanical research fields such as plant morphology and stress resistance, there are still limitations. This review summarizes the application of EIS in plant root measurement. The experiment scheme, instrument and electrode, excitation frequency range, root electrical characteristics, equivalent circuit, and combination of EIS and artificial intelligence (AI) are discussed. Furthermore, the review suggests that future research should focus on miniaturization of measurement equipment, standardization of planting environment and intelligentization of root diagnosis, so as to better apply EIS technology to in situ root nondestructive measurement.


Sign in / Sign up

Export Citation Format

Share Document