Sensitivity analysis in the transient recovery voltage in an industrial power system✰

2021 ◽  
Vol 197 ◽  
pp. 107309
Author(s):  
R.S. Ferreira
2015 ◽  
Vol 64 (3) ◽  
pp. 441-458 ◽  
Author(s):  
Piotr Oramus ◽  
Tomasz Chmielewski ◽  
Tomasz Kuczek ◽  
Wojciech Piasecki ◽  
Marcin Szewczyk

Abstract Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.


2016 ◽  
Vol 136 (2) ◽  
pp. 170-174 ◽  
Author(s):  
Tadashi Koshizuka ◽  
Yasuhiko Taniguchi ◽  
Eiichi Haginomori ◽  
Hisatoshi Ikeda ◽  
Keisuke Udagawa

2019 ◽  
Vol 139 (8) ◽  
pp. 522-526
Author(s):  
Kyoya Nonaka ◽  
Tadashi Koshizuka ◽  
Eiichi Haginomori ◽  
Hisatoshi Ikeda ◽  
Takeshi Shinkai ◽  
...  

Electronics ◽  
2021 ◽  
Vol 10 (13) ◽  
pp. 1598
Author(s):  
Dongmin Kim ◽  
Kipo Yoon ◽  
Soo Hyoung Lee ◽  
Jung-Wook Park

The energy storage system (ESS) is developing into a very important element for the stable operation of power systems. An ESS is characterized by rapid control, free charging, and discharging. Because of these characteristics, it can efficiently respond to sudden events that affect the power system and can help to resolve congested lines caused by the excessive output of distributed generators (DGs) using renewable energy sources (RESs). In order to efficiently and economically install new ESSs in the power system, the following two factors must be considered: the optimal installation placements and the optimal sizes of ESSs. Many studies have explored the optimal installation placement and the sizing of ESSs by using analytical approaches, mathematical optimization techniques, and artificial intelligence. This paper presents an algorithm to determine the optimal installation placement and sizing of ESSs for a virtual multi-slack (VMS) operation based on a power sensitivity analysis in a stand-alone microgrid. Through the proposed algorithm, the optimal installation placement can be determined by a simple calculation based on a power sensitivity matrix, and the optimal sizing of the ESS for the determined placement can be obtained at the same time. The algorithm is verified through several case studies in a stand-alone microgrid based on practical power system data. The results of the proposed algorithm show that installing ESSs in the optimal placement could improve the voltage stability of the microgrid. The sizing of the newly installed ESS was also properly determined.


Sign in / Sign up

Export Citation Format

Share Document