Experimental studies on a corrugated plate heat exchanger for small temperature difference applications

2012 ◽  
Vol 36 ◽  
pp. 242-248 ◽  
Author(s):  
M. Faizal ◽  
M.R. Ahmed
Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8280
Author(s):  
Jeonggyun Ham ◽  
Gonghee Lee ◽  
Dong-wook Oh ◽  
Honghyun Cho

In this study, computational fluid dynamics (CFD) analysis was performed to investigate the cause of the thermal stratification in the channel and the temperature non-uniformity of the plate heat exchanger. The flow velocity maldistribution of the channel and the merging parts caused temperature non-uniformity in the channel width direction. The non-uniformity of flow velocity and temperature in the channel is shown in Section 1 > Section 3 > Section 2 from the heat exchanger. The non-uniform temperature distribution in the channel caused channel stratification and non-uniform outlet temperature. Stratification occurred at the channel near the merging due to the flow rate non-uniformity in the channel. In particular, as the mass flow rate increased from 0.03 to 0.12 kg/s and the effectiveness increased from 0.436 to 0.615, the cold-side stratified volume decreased from 4.06 to 3.7 cm3, and the temperature difference between the stratified area and the outlet decreased from 1.21 K to 0.61 K. The increase in mass flow and the decrease in temperature difference between the cold and hot sides alleviated the non-uniformity of the outlet temperature due to the increase in effectiveness. Besides, as the inlet temperature difference between the cold and the hot side increases, the temperature non-uniformity at the outlet port is poor due to the increase in the stratified region at the channel, and the distance to obtain a uniform temperature in the outlet pipe increases as the temperature at the hot side increases.


2020 ◽  
Vol 4 (2) ◽  
pp. 167-172
Author(s):  
Sreedhar Rao Battula ◽  
Keerthana Reddy Chittireddy ◽  
Meena Pullurwar ◽  
Kishore Kumar Sriramoju

This paper reports an experimental comparative thermal analysis of a flat plate heat exchanger and corrugated plate heat exchanger (CPHE) of different corrugation angles using ethylene glycol as test fluid. The experiments were carried out counter current mode using water as hot fluid at 75°C.  Design of each plate provided with eleven thermocouple sensors to determine the temperatures, in which seven were used to measure the surface temperature of plate and four were used to measure the inlet and outlet bulk temperature of cold and hot fluids.  The mass flow rate of test fluid, varied between 0.5 to 4 liters per minute and corresponding steady state temperatures is measured. Using experimental readings, temperature difference between the inlet and outlet streams (DT), logarithmic mean temperature difference (LMTD) and overall heat transfer coefficient (U) are determined. The obtained DT and U values of corrugation angles (300, 500) of CPHE were compared with those of flat plate heat exchangers. For corrugation angle of 30° and 50°, the DT and U values increases with increase of mass flow rate of the fluid.


2013 ◽  
Vol 44 (8) ◽  
pp. 761-789 ◽  
Author(s):  
Farzaneh Hajabdollahi ◽  
Zahra Hajabdollahi ◽  
Hassan Hajabdollahi