Design of new natural antioxidant active packaging: Screening flowsheet from pure essential oils and vegetable oils to ex vivo testing in meat samples

Food Control ◽  
2021 ◽  
Vol 120 ◽  
pp. 107536
Author(s):  
Magdalena Wrona ◽  
Filomena Silva ◽  
Jesús Salafranca ◽  
Cristina Nerín ◽  
María José Alfonso ◽  
...  
2014 ◽  
Vol 136 (11) ◽  
Author(s):  
Wilfried Bürzle ◽  
Edoardo Mazza ◽  
John J. Moore

Puncture testing has been applied in several studies for the mechanical characterization of human fetal membrane (FM) tissue, and significant knowledge has been gained from these investigations. When comparing results of mechanical testing (puncture, inflation, and uniaxial tension), we have observed discrepancies in the rupture sequence of FM tissue and significant differences in the deformation behavior. This study was undertaken to clarify these discrepancies. Puncture experiments on FM samples were performed to reproduce previous findings, and numerical simulations were carried out to rationalize particular aspects of membrane failure. The results demonstrate that both rupture sequence and resistance to deformation depend on the samples' fixation. Soft fixation leads to slippage in the clamping, which reduces mechanical loading of the amnion layer and results in chorion rupturing first. Conversely, the stiffer, stronger, and less extensible amnion layer fails first if tight fixation is used. The results provide a novel insight into the interpretation of ex vivo testing as well as in vivo membrane rupture.


2002 ◽  
Vol 9 (1) ◽  
pp. 96-99 ◽  
Author(s):  
Armando L Karara ◽  
Viviana F Bumaschny ◽  
Gabriel L Fiszman ◽  
Cecilia C Casais ◽  
Gerardo C Glikin ◽  
...  

2010 ◽  
Vol 4 (2) ◽  
Author(s):  
Andrew Rau ◽  
Mary Frecker ◽  
Abraham Mathew ◽  
Eric Pauli

This paper presents a 3.0 mm diameter endoscopic forceps design for use in minimally invasive surgical procedures, which require significant grasping and spreading forces. Models of the proposed design predict considerable improvements in the opening range (140%) and force application (87%) for both grasping and spreading when compared with currently used endoscopic forceps. Several of the tool’s design characteristics promote fail-safe malfunctions, including locking before catastrophic failure and the decreased likelihood in detached parts. Initial benchtop testing showed good agreement between prototype performance and model prediction. Frictional losses experienced during testing were found to depend on load orientation. A surgical prototype is currently being manufactured for ex vivo testing.


2020 ◽  
Vol 117 ◽  
pp. 104842
Author(s):  
Jelena Marinković ◽  
Dragana Mitić Ćulafić ◽  
Biljana Nikolić ◽  
Stefana Đukanović ◽  
Tatjana Marković ◽  
...  

2013 ◽  
Vol 64 (8) ◽  
pp. 921-928 ◽  
Author(s):  
Veronica Sirocchi ◽  
Giovanni Caprioli ◽  
Cinzia Cecchini ◽  
Maria Magdalena Coman ◽  
Alberto Cresci ◽  
...  

2017 ◽  
Vol 141 (5) ◽  
pp. 3492-3492
Author(s):  
Christine E. Dalton ◽  
Zachary A. Coffman ◽  
Garrett Wagner ◽  
Timothy E. Doyle

Sign in / Sign up

Export Citation Format

Share Document