Construct validity and test-retest reliability of a free mobile application for spatio-temporal gait analysis in Parkinson’s disease patients

2020 ◽  
Vol 79 ◽  
pp. 86-91
Author(s):  
Sergio Clavijo-Buendía ◽  
Francisco Molina-Rueda ◽  
Patricia Martín-Casas ◽  
Paulina Ortega-Bastidas ◽  
Esther Monge-Pereira ◽  
...  
Folia Medica ◽  
2013 ◽  
Vol 55 (3-4) ◽  
pp. 56-62 ◽  
Author(s):  
Stefka G. Mantarova ◽  
Irena V. Velcheva ◽  
Spaska O. Georgieva ◽  
Katerina I. Stambolieva

ABSTRACT The last twenty years have witnessed a surge of interest in the autonomic symptoms in Parkinson’s disease (PD) and the possibilities to diagnose and treat them. The specialized questionnaire assessing the autonomic symptoms in Parkinson’s disease (SCOPA-AUT) has been validated and available in English, Dutch and Spanish. In this study we aim at evaluating the validity, reliability and applicability of the Bulgarian version of SCOPAAUT (SCOPA-AUT-BG ). PATIENTS AND METHODS: The study included 55 patients with idiopathic PD (mean age 64.4 ± 8.9 yrs), and 40 healthy controls (mean age 58.5 ± 9.4 yrs). Clinical severity and disease stage were assessed by United Parkinson’s disease rating scale (UPRDS) and Hoen and Yahr (H&Y). Thirty-two of the PD patients completed SCOPA-AUT-BG again after a 7-day interval. Questionnaire reliability was analyzed by determining the internal consistency, homogeneity, discriminatory and construct validity and test-retest reliability. RESULTS: Analyses showed good internal consistency of the summary evaluation of SCOPAAUT- BG (coefficient alpha of Cronbach = 0.79), which indicates the high reliability of the questionnaire. The lowest Cronbach’s alpha coefficient (0.53) was found for the subscale “cardiovascular functions”. A dominant role belongs to the subscales for gastrointestinal and urinary functions (Cronbach’s Alpha > 0.7), where a significantly high correlation of PD with the UPDRS scale was observed. We found high test-retest reliability based on the responses associated with dysfunction of the gastrointestinal, urinary, thermoregulatory and pupillary autonomic systems. The correlation of the results of SCOPA-AUT-BG with UPDRS is higher than that with H&Y, and the construct validity is high except for the cardiovascular and pupillomotor functions subscales. CONCLUSION: The results of this study show that SCOPA-AUT-BG is a valid and reliable specialized questionnaire to evaluate autonomic function in patients with Parkinson’s disease. Using it allows for more detailed clinical evaluation of these patients and justifies the need to refer them to specialized examination of autonomic functions.


2019 ◽  
Vol 71 ◽  
pp. 177-180
Author(s):  
Mira Ambrus ◽  
Jose A. Sanchez ◽  
Jose A Sanchez Miguel ◽  
Fernandez del-Olmo

2021 ◽  
Author(s):  
Maximilien Burq ◽  
Erin Rainaldi ◽  
King Chung Ho ◽  
Chen Chen ◽  
Bastiaan R Bloem ◽  
...  

Sensor-based remote monitoring could help us better track Parkinson's disease (PD) progression, and measure patients' response to putative disease-modifying therapeutic interventions. To be useful, the remotely-collected measurements should be valid, reliable and sensitive to change, and people with PD must engage with the technology. We developed a smartwatch-based active assessment that enables unsupervised measurement of motor signs of PD. 388 study participants with early-stage PD (Personalized Parkinson Project, 64% men, average age 63 years) wore a smartwatch for a median of 390 days, allowing for continuous passive monitoring. Participants performed unsupervised motor tasks both in the clinic (once) and remotely (twice weekly for one year). Dropout rate was 2% at the end of follow-up. Median wear-time was 21.1 hours/day, and 59% of per-protocol remote assessments were completed. In-clinic performance of the virtual exam verified that most participants correctly followed watch-based instructions. Analytical validation was established for in-clinic measurements, which showed moderate-to-strong correlations with consensus MDS-UPDRS Part III ratings for rest tremor (R=0.70), bradykinesia (R=-0.62), and gait (R=-0.46). Test-retest reliability of remote measurements, aggregated monthly, was good-to-excellent (ICC: 0.75 - 0.96). Remote measurements were sensitive to the known effects of dopaminergic medication (on vs off Cohen's d: 0.19 - 0.54). Of note, in-clinic assessments often did not reflect the patients' typical status at home. This demonstrates the feasibility of using smartwatch-based unsupervised active tests, and establishes the analytical validity of associated digital measurements. Weekly measurements can create a more complete picture of patient functioning by providing a real-life distribution of disease severity, as it fluctuates over time. Sensitivity to medication-induced change, together with the improvement in test-retest reliability from temporal aggregation implies that these methods could help reduce sample sizes needed to demonstrate a response to therapeutic intervention or disease progression.


BMC Neurology ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Samuel Ånfors ◽  
Ann-Sofi Kammerlind ◽  
Maria H. Nilsson

Abstract Background People with Parkinson’s disease are less physically active than controls. It is important to promote physical activity, which can be assessed using different methods. Subjective measures include physical activity questionnaires, which are easy and cheap to administer in clinical practice. Knowledge of the psychometric properties of physical activity questionnaires for people with Parkinson’s disease is limited. The aim of this study was to evaluate the test-retest reliability of physical activity questionnaires in individuals with Parkinson’s disease without cognitive impairment. Methods Forty-nine individuals with Parkinson’s disease without cognitive impairment participated in a test-retest reliability study. At two outpatient visits 8 days apart, the participants completed comprehensive questionnaires and single-item questions: International Physical Activity Questionnaire-Short Form (IPAQ-SF), Physical Activity Scale for the Elderly (PASE), Saltin-Grimby Physical Activity Level Scale (SGPALS) and Health on Equal Terms (HOET). Test-retest reliability was evaluated using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), limits of agreement, weighted kappa or the Svensson method. Results Several of the physical activity questionnaires had relatively low test-retest reliability, including the comprehensive questionnaires (IPAQ-SF and PASE). Total physical activity according to IPAQ-SF had an ICC value of 0.46 (95% confidence interval [CI], 0.21–0.66) and SEM was 2891 MET-min/week. The PASE total score had an ICC value of 0.66 (95% CI, 0.46–0.79), whereas the SEM was 30 points. The single-item scales of SGPALS-past six months (SGPALS-6 m) and HOET question 1 (HOET-q1) with longer time frames (6 or 12 months, respectively) showed better results. Weighted kappa values were 0.64 (95% CI, 0.45–0.83) for SGPALS-6 m and 0.60 (95% CI, 0.39–0.80) for HOET-q1, whereas the single-item questions with a shorter recall period had kappa values < 0.40. Conclusions Single-item questions with a longer time frame (6 or 12 months) for physical activity were shown to be more reliable than multi-item questionnaires such as the IPAQ-SF and PASE in individuals with Parkinson’s disease without cognitive impairments. There is a need to develop a core outcome set to measure physical activity in people with Parkinson’s disease, and there might be a need to develop new physical activity questionnaires.


2010 ◽  
Vol 68 (1) ◽  
pp. 81-86 ◽  
Author(s):  
Roberta de Melo Roiz ◽  
Enio Walker Azevedo Cacho ◽  
Manoela Macedo Pazinatto ◽  
Julia Guimarães Reis ◽  
Alberto Cliquet Jr ◽  
...  

There is a lack of studies comparing the kinematics data of idiopathic Parkinson's disease (IPD) patients with healthy elder (HE) subjects, and when there is such research, it is not correlated to clinical measures. OBJECTIVE: To compare the spatio-temporal and kinematic parameters of Parkinsonian gait with the HE subjects group and measure the relation between these parameters and clinical instruments. METHOD: Twelve patients with IPD and fifteen HE subjects were recruited and evaluated for clinical instruments and gait analysis. RESULTS: There were statistically significant differences between HE group and the IPD group, in stride velocity, in stride length (SL), and in the hip joint kinematic data: on initial contact, on maximum extension during terminal contact and on maximum flexion during mid-swing. Regarding the clinical instruments there were significant correlated with in stride velocity and SL. CONCLUSION: Clinical instruments used did not present proper psychometric parameters to measure the IPD patient's gait, while the 3D system characterized it better.


2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Perla Massai ◽  
Francesca Colalelli ◽  
Julita Sansoni ◽  
Donatella Valente ◽  
Marco Tofani ◽  
...  

Introduction. The Geriatric Depression Scale (GDS) is commonly used to assess depressive symptoms, but its psychometric properties have never been examined in Italian people with Parkinson’s disease (PD). The aim of this study was to study the reliability and validity of the Italian version of the GDS in a sample of PD patients. Methods. The GDS was administered to 74 patients with PD in order to study its internal consistency, test-retest reliability, construct, and discriminant validity. Results. The internal consistency of GDS was excellent (α = 0.903), as well as the test-retest reliability (ICC = 0.941 [95% CI: 0.886–0.970]). GDS showed a strong correlation with instruments related to the depression (ρ = 0.880) in PD (ρ = 0.712) and a weak correlation with generic measurement instruments (−0.320 < ρ <−0.217). An area under the curve of 0.892 (95% CI 0.809–0.975) indicated a moderate capability to discriminate depressed patients to nondepressed patient, with a cutoff value between 15 and 16 points that predicts depression (sensitivity = 87%; specificity = 82%). Conclusion. The GDS is a reliable and valid tool in a sample of Italian PD subjects; this scale can be used in clinical and research contexts.


2021 ◽  
pp. 1-8
Author(s):  
Ya-Yun Lee ◽  
Ming-Hao Li ◽  
Jer-Junn Luh ◽  
Chun-Hwei Tai

BACKGROUND: Recent advances in technology have warranted the use of wearable sensors to monitor gait and posture. However, the psychometric properties of using wearable devices to measure gait-related outcomes have not been fully established in patients with Parkinson’s disease (PD). OBJECTIVE: This study aimed to investigate the test-retest reliability of body-worn sensors for gait evaluation in people with PD. Additionally, the influence of disease severity on the reliability was determined. METHODS: Twenty individuals with PD were recruited. During the first evaluation, the participants wore inertial sensors on their shoes and walked along a walkway thrice at their comfortable walking speed. The participants were then required to return to the lab after 3–5 days to complete the second evaluation with the same study procedure. Test-retest reliability of gait-related outcomes were calculated. To determine whether the results would be affected by disease severity, reliability was re-calculated by subdividing the participants into early and mid-advanced stages of the disease. RESULTS: The results showed moderate to good reliability (ICC = 0.64–0.87) of the wearable sensors for gait assessment in the general population with PD. Subgroup analysis showed that the reliability was higher among patients at early stages (ICC = 0.71–0.97) compared to those at mid-advanced stages (ICC = 0.65–0.81) of PD. CONCLUSIONS: Wearable sensors could reliably measure gait parameters in people with PD, and the reliability was higher among individuals at early stages of the disease compared to those at mid-advanced stages. Absolute reliability values were calculated to act as references for future studies.


BMC Neurology ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Galina Stoyanova-Piroth ◽  
Ivan Milanov ◽  
Katerina Stambolieva

Abstract Background The purpose of the present study was to translate and cross-culturally adapt the King’s Parkinson’s Disease Pain Scale (KPPS) into Bulgarian and to investigate its psychometric properties in order to provide a validated Parkinson’s disease-specific pain instrument in Bulgarian language (KPPS-BG). Methods Translation into Bulgarian and a cultural adaptation were performed to obtain KPPS-BG. A total of 162 patients with idiopathic Parkinson’s disease were screened for pain using the complementary to the KPPS questionnaire – King’s Parkinson’s Disease Pain Questionnaire (KPPQ). KPPS-BG domain and total scores were calculated and internal consistency, construct validity and test-retest reliability were examined for 129 patients having one or more positive items in the KPPQ-BG. Results 79.6 % of the patients reported one or more types of pain. The most common type was musculoskeletal pain (83.7 %), followed by nocturnal pain (55.0 %), fluctuation-related pain (50.1 %), radicular pain (43.4 %), chronic pain (31.0 %), discoloration, edema/swelling (27.1 %) and, oro-facial pain (14.3 %). Mean KPPS-BG total score was 21.1 ± 17.3 SD. KPPS-BG showed a good reliability (Cronbach’s alpha 0.75). The test-retest reliability of the KPPS-BG was high and the intraclass correlation coefficient was 0.92, demonstrating а good repeatability. KPPS-BG total score was higher in patients with postural instability gait difficulty motor subtype, compared to tremor-dominant or indeterminate subtype. Significant positive correlations were found between KPPS-BG total score and modified H&Y, Movement Disorders Society Unified Parkinson’s Disease Rating Scale part III. Conclusions The KPPS-BG constitutes a reliable, comprehensive and useful tool for pain assessment in native Bulgarian patients with Parkinson’s disease.


Sign in / Sign up

Export Citation Format

Share Document