scholarly journals Evaluation of point-of-care testing for brain natriuretic peptide in the out-patient clinic

2015 ◽  
Vol 24 ◽  
pp. S79
Author(s):  
M. Matthews ◽  
R. Doughty ◽  
H. McGrinder ◽  
J. Hannah ◽  
A. Meisner
Author(s):  
Simona Storti ◽  
Concetta Prontera ◽  
Michele Emdin ◽  
Claudio Passino ◽  
Paola Prati ◽  
...  

AbstractThe aim of this study was to evaluate the analytical performance of a recently available immunoassay for brain natriuretic peptide (BNP), based on microparticle enzyme immunoassay (MEIA, AxSYM System, Abbott Laboratories), whose analytical characteristics and clinical results were compared with those of a point of care testing (POCT) method (TRIAGE system, Biosite Diagnostics). The within-run and total imprecision of the MEIA system were 18.4% and 19.8% at 21 ng/l, 8.0% and 14.8% at 183 ng/l, and 5.7% and 14.0% at 319 ng/l, respectively. The detection limit of the MEIA system was tested by repeatedly measuring (n = 20) the 0 calibrator in four different runs; a mean +3 SD value of 5.6 ± 4.8 ng/l (range 1.8–12.6 ng/l) was obtained. A close linear relationship (MEIA = –22.5 + 1.71 POCT method, R = 0.950, n = 296) was found (BNP concentration: 5–5500 ng/l), with a significant bias (mean difference: 164.8 ng/l, p < 0.0001). Mean BNP concentration measured in 94 reference subjects (57 women and 37 men; mean age 43.5 ± 14.0 years) was higher with MEIA than POCT, (25.9 ± 32.7 ng/l vs. 11.7 ± 8.9 ng/l, p < 0.0001). The same trend was observed also in 202 cardiac patients (620.6 ± 1082.2 ng/l vs. 386.1 ± 594.5 ng/l, p < 0.0001). Our data suggest that MEIA and POCT have quite similar analytical performance but different clinical results. Then, different reference values, as well as cut-off values, should be taken into account for the clinical use of these two immunoassays.


Author(s):  
Valentina Pecoraro ◽  
Giuseppe Banfi ◽  
Luca Germagnoli ◽  
Tommaso Trenti

Background Point-of-care testing has been developed to provide rapid test results. Most published studies focus on analytical performance, neglecting its impact on patient outcomes. Objective To review the analytical performance and accuracy of point-of-care testing specifically planned for immunoassay and to evaluate the impact of faster results on patient management. Methods A search of electronic databases for studies reporting immunoassay results obtained in both point-of-care testing and central laboratory scenarios was performed. Data were extracted concerning the study details, and the methodological quality was assessed. The analytical characteristics and diagnostic accuracy of six points-of-care testing: troponin, procalcitonin, parathyroid hormone, brain natriuretic peptide, C-reactive protein and neutrophil gelatinase-associated lipocalin were evaluated. Results A total of 116 scientific papers were analysed. Studies measuring procalcitonin, parathyroid hormone and neutrophil gelatinase-associated lipocalin reported a limited impact on diagnostic decisions. Seven studies measuring C-reactive protein claimed a significant reduction of antibiotic prescription. Several authors evaluated brain natriuretic peptide or troponin reporting faster decision-making without any improvement in clinical outcome. Forty-four per cent of studies reported analytical data, showing satisfactory correlations between results obtained through point-of-care testing and central laboratory setting. Half of studies defined the diagnostic accuracy of point-of-care testing as acceptable for troponin (median sensitivity and specificity: 74% and 94%, respectively), brain natriuretic peptide (median sensitivity and specificity: 82% and 88%, respectively) and C-reactive protein (median sensitivity and specificity 85%). Conclusions Point-of-care testing immunoassay results seem to be reliable and accurate for troponin, brain natriuretic peptide and C-reactive protein. The satisfactory analytical performance, together with an excellent practicability, suggests that it could be a consistent tool in clinical practice, but data are lacking regarding the patient outcomes.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
K M Cygulska ◽  
Ł Figiel ◽  
D Slawek ◽  
A Karzkowiak ◽  
M Wraga ◽  
...  

Abstract Background Acetylsalicylic acid (ASA) remains the principal medication for secondary prevention of atherosclerotic complications. Resistance to ASA (ASAres) is multifactorial and results in insufficient reduction of platelet reactivity through incomplete inhibition of thromboxane A2 (TXA2) synthesis. There is controversy regarding the optimal preventive ASA dose with common daily use of 75 mg in many European countries. Purpose The aim of our study is to reassess the prevalence and predictors of ASAres in contemporary cohort of coronary disease (CAD) patients (pts) on stable therapy with 75 mg ASA. Methods We studied 205 patients (36,6% females) with stable CAD and concomitant atherosclerotic disease history (ischemic stroke 10,2%, peripheral vascular disease 8,3%,) and type 2 diabetes in 39,5% on stable regimen 75 mg ASA for a minimum of 1 month (mean age 68,2±9,7 years, mean BMI 27,3±4,7 kg/m2). ASAres was defined as ARU (aspirin reaction unit) ≥550 using point-of-care VerifyNow Aspirin test. Exclusion criteria were: recent (up to 2 months) acute coronary syndrome, cancer, dermatological disease, epilepsy or other chronic neurological diseases, exacerbation of allergic disease, rheumatoid arthritis, periodontal disease, alcoholism, drug addiction, vegetarianism, veganism and other specific diets, and known thrombophilia. The population received standard concomitant preventive treatments including RAA blockade in 88,3%, beta-blockers in 85,9%, statins in 93,2%, and proton pump inhibitors (PPI) in 65,4%. History of infarction was present in 37% and mean left ventricular ejection fraction was 47% (18–75%). Results ASAres was detected in 11,7% of patients. Modest but significant correlations (Spearman's coefficient of rank correlation rho) were detected between ARU and C-reactive protein (CRP) (rs=0,15; p=0,030), N-terminal pro-brain natriuretic peptide (NT-proBNP) (rs=0,15; p=0,039), body weight (rs=0,22; p=0,0014), BMI (rs=0,207, p=0,0029). No significant differences in ASAres we found with regard to sex, other risk factors or concomitant medication, including PPI. However, in ASAres pts median concentrations of NT-proBNP were significantly higher (median 311 vs. 646pg/ml; p=0,046). In multivariate analysis NT-proBNP emerged as the only independent predictor of ASAres (AUC=0,626; p=0,027 with threshold value of 327,3 pg/ml resulting with negative predictive value of 16,98% and positive predictive value of 93,95% for ASAres). Conclusion ASAres has significant prevalence in this secondary prevention CAD cohort treated with 75 mg daily dose. NT-proBNP was identified as the only independent predictor in multivariate analysis. This finding may be important especially for pts with heart failure of ischemic etiology. The implications of switching into 100 mg or higher ASA doses remain to be investigated. Acknowledgement/Funding study was supported from unrestricted research grant from Aflofarm SA


2011 ◽  
Vol 409 (1) ◽  
pp. 7-13 ◽  
Author(s):  
Jonas Melin ◽  
Gerd Rundström ◽  
Christer Peterson ◽  
Jimmy Bakker ◽  
Brian D. MacCraith ◽  
...  

2017 ◽  
Vol 7 (4) ◽  
pp. 302-310 ◽  
Author(s):  
Morten T Bøtker ◽  
Maren T Jørgensen ◽  
Carsten Stengaard ◽  
Sophie-Charlott Seidenfaden ◽  
Mona Tarpgaard ◽  
...  

Purpose: The purpose of this study was to examine whether the addition of brain natriuretic peptide measurement to the routine diagnostic work-up by prehospital critical care team physicians improves triage in patients with severe dyspnoea. Methods: Prehospital critical care team physicians randomly assigned patients older than 18 years with severe dyspnoea to routine diagnostic work-up or diagnostic work-up with incorporated point-of-care N-terminal pro-brain natriuretic peptide (NT-proBNP) measurement. The primary endpoint was the proportion of patients with dyspnoea of primary cardiac origin triaged directly to a department of cardiology. Results: A total of 747 patients were randomly assigned and 711 patients consented to participate, 350 were randomly assigned to the NT-proBNP group and 361 to the routine work-up group. NT-proBNP was measured in 90% (315/350) of patients in the NT-proBNP group and in 19% (70/361) of patients in the routine work-up group. There was no difference in the proportion of patients with dyspnoea of primary cardiac origin triaged directly to a department of cardiology between the NT-proBNP group and the routine work-up group (75% vs. 69%, P=0.22) in the intention-to-treat analysis. Sensitivity analysis according to the de facto diagnostics performed showed results consistent with this. No differences in hospital length of stay, intensive care unit admission rates or mortality between the NT-proBNP group and the routine work-up group were observed. Conclusion: Routine supplementary point-of-care measurement of NT-proBNP in patients with severe dyspnoea did not improve triage of patients with dyspnoea primarily caused by heart disease. ClinicalTrials.gov identifier NCT02050282.


Sign in / Sign up

Export Citation Format

Share Document