Laboratory study to determine the critical moisture level for mould growth on building materials

2012 ◽  
Vol 73 ◽  
pp. 23-32 ◽  
Author(s):  
Pernilla Johansson ◽  
Annika Ekstrand-Tobin ◽  
Thomas Svensson ◽  
Gunilla Bok
2020 ◽  
Vol 172 ◽  
pp. 20002
Author(s):  
Pernilla Johansson ◽  
Lukas Lång ◽  
Gunilla Bok ◽  
Carl-Magnus Capener

The susceptibility for mould growth varies among different building materials. One way to describe the susceptibility is the lowest RH at which mould can grow on a specific material, the critical moisture level (RHcrit). Determining RHcrit for materials provide the basis for material choice in designs where moisture and temperature conditions are known. In this study, RHcrit of 21different products were determined according to SIS-TS 41:2014/SPMet 4927. This test method is developed based on the results of a variety of laboratory studies and validated by field studies. Test specimens were inoculated with a suspension containing spores from six different mould fungi and were then incubated in moisture chambers at four levels of RH at 22 °C. After 12 weeks specimens were analysed for mould growth. RHcrit was determined based on the lowest RH at which mould grew on the specimens. RHcrit varied among different products, even between product belonging to a similar group of material, for example, calcium silicate boards or gypsum boards. The results show, and confirm, previous findings that it is not possible to estimate RHcrit for a specific product based on material group. Instead, each product must be tested.


Author(s):  
Sanne Johansson ◽  
Kristin Balksten ◽  
Paulien Brigitte Strandberg-de Bruijn

Microbial growth often thrives in humid conditions, at high relative humidity. Moulds are complex organisms; many types of mould are able to survive strong variations in humidity and temperature, such as those on building façades. For some building materials a critical relative humidity is determined, which functions as a theoretical threshold; at this (or lower) relative humidity microbial growth will likely not occur. Hemp-lime is a building material that consists of hemp shiv (the woody core parts of the hemp stem) and building lime. It is a material that can be used for walls, and even though it has been used for more than 20 years, thusfar little is known about its critical moisture levels for microbial growth. The aim of this research was therefore to determine at what relative humidity microbial growth occurs on carbonated hemp-lime material, and to study if there is a protective influence of a carbonated lime binder on the hemp shiv. The objective was to study microbial growth on hemp shiv, hemp-lime and on hemp with a thin layer of lime at three relative humidity (75 %, 85 % and 95 %) and at two different temperatures (15°C and 23°C); conditions that could occur naturally in a hemp-lime façade exposed to high rain loads in a northern European climate. Hemp shiv seems to have a relatively low resistance to microbial growth, similar to that of wood. However, because the hemp is protected by lime it can withstand much higher relative humidity without microbial growth occurring on the material. The critical moisture level for hemp-lime seemed to occur between 75 and 85 % RH, while the material was completely without microbial growth at 75 % RH. The lime had a protective effect on the hemp and acted as a mould inhibitor, both over time and with varying temperature and humidity.


2020 ◽  
Vol 172 ◽  
pp. 20001
Author(s):  
Pernilla Johansson ◽  
Thomas Svensson

Mould growth in buildings is a complex process, affected by moisture and temperature, the properties of the building material as well as characteristics of the mould fungi. The complexity poses challenges when assessing the risk of mould growth in buildings. Mathematical models are often used to predict whether mould will grow in a part of building with expected RH and temperature conditions. The models can be described as static or dynamic. In a previous round-robin study, comparing results from models with observations from field studies, the outcome of the dynamic models evaluated depended on the user of the model. Also, the models often underestimated the risk of mould growth. A better agreement was found for static models, especially for the PJ-model. It is a part of a standardised technical specification (SIS-TS 41:2014) and has not previously been described as a model. The critical moisture level (RHcrit), determined by tests according to the method, is used as input. Thus, the subjectivity in the predictions is reduced. RHcrit is the lowest moisture level at which mould can grow and is temperature-dependent. The PJ-model provides an equation to estimate RHcrit at typical temperatures in buildings. If RH in a building section exceeds the limit values at the current temperature, growth is predicted. This paper describes the PJ-model version 1.0, some of the extensive work performed during the development and validation of the model and the ongoing work to refine the model to include considering transient conditions and measurement uncertainties.


2013 ◽  
Vol 62 ◽  
pp. 201-209 ◽  
Author(s):  
Pernilla Johansson ◽  
Thomas Svensson ◽  
Annika Ekstrand-Tobin

Geoderma ◽  
2019 ◽  
Vol 338 ◽  
pp. 281-290 ◽  
Author(s):  
Cecilie Hermansen ◽  
Per Moldrup ◽  
Karin Müller ◽  
Peter Weber Jensen ◽  
Carlo van den Dijssel ◽  
...  

2013 ◽  
Vol 48 (1-2) ◽  
pp. 53-65 ◽  
Author(s):  
Magnus Åhs ◽  
Lars-Olof Nilsson ◽  
Mohsen Ben Haha

Sign in / Sign up

Export Citation Format

Share Document