Continuous fast Fourier transforms cyclic voltammetry as a new approach for investigation of skim milk k-casein proteolysis, a comparative study

2017 ◽  
Vol 103 ◽  
pp. 972-977 ◽  
Author(s):  
Javad Shabani Shayeh ◽  
Yahya Sefidbakht ◽  
Seyed Omid Ranaei Siadat ◽  
Kaveh Niknam
2016 ◽  
Vol 2016 ◽  
pp. 1-9 ◽  
Author(s):  
Álvaro de Jesús Ruíz-Baltazar ◽  
Simón Yobanny Reyes-López ◽  
D. Larrañaga ◽  
R. Pérez

Nanoparticles of Ag with different sizes and structures were obtained and studied. Two methods for reductions of Ag ions were employed, chemical reduction by sodium borohydride and ethylene glycol. Cuboctahedral and icosahedral structures were obtained. Molecular simulations were carried out in order to evaluate the reactivity of both structures. On the other hand, the electrochemical activity and antibacterial effect (E. coli) of the cuboctahedral and icosahedral structures were measured experimentally. The results obtained by molecular simulation, cyclic voltammetry, and antibacterial effect were compared and discussed in this work.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
J. Buijs ◽  
J. van der Gucht ◽  
J. Sprakel

Abstract Laser speckle imaging is a powerful imaging technique that visualizes microscopic motion within turbid materials. At current two methods are widely used to analyze speckle data: one is fast but qualitative, the other quantitative but computationally expensive. We have developed a new processing algorithm based on the fast Fourier transform, which converts raw speckle patterns into maps of microscopic motion and is both fast and quantitative, providing a dynamnic spectrum of the material over a frequency range spanning several decades. In this article we show how to apply this algorithm and how to measure a diffusion coefficient with it. We show that this method is quantitative and several orders of magnitude faster than the existing quantitative method. Finally we harness the potential of this new approach by constructing a portable laser speckle imaging setup that performs quantitative data processing in real-time on a tablet.


2011 ◽  
Vol 65 ◽  
pp. 299-302 ◽  
Author(s):  
Shou Qiang Men ◽  
Christian Resagk

A simple calibration system for magnetic field sensors was designed, and experiments were carried out to calibrate two-dimensional fluxgate sensors and a sensor ring composed of eight fluxgate sensors. Fast Fourier Transforms and trapezoidal numerical integrals were applied to deal with the raw signals. It is found that it is not suitable to apply fast Fourier Transforms only to deal with signals with several peaks close to each other, but trapezoidal numerical integrals should also be used in combination with the FFT method.


Sign in / Sign up

Export Citation Format

Share Document