WITHDRAWN: A study on the on-line measurement of transmission line impedances for improved relaying protection

Author(s):  
Il-Dong Kim ◽  
Raj K. Aggarwal
2012 ◽  
Vol 239-240 ◽  
pp. 372-375
Author(s):  
Tao Wang ◽  
Bing Li ◽  
Hong Xing Yang

Traditional transmission line tower grounding resistance measurements have many shortcomings, in order to make up the defects the model of transmission line tower with good conductor wires and multiple grounding leads was builded, and then the algorithm of tower grounding resistance on-line measurement was proposed. On this condition, a system based on this algorithm was designed and further analysis of the error during data processing was conducted. At last, the MATLAB simulation indicates that the algorithm has a accuracy that meets the practical requirements.


2021 ◽  
Vol 2143 (1) ◽  
pp. 012035
Author(s):  
Jie Tang ◽  
Zhidu Huang ◽  
Zhimei Cui

Abstract With the increasing demand for high voltage and UHV transmission, higher and higher requirements are put forward for transmission line monitoring and fault diagnosis. The traditional line measurement method has many shortcomings, which cannot ensure the measurement accuracy, measurement efficiency and high cost. Based on this, this paper first studies the principle of machine vision on-line measurement, then analyses the on-line measurement process of transmission line crossing point based on machine vision, and finally gives the error source and amelioration measures of transmission line crossing point on-line measurement.


Author(s):  
John F. Mansfield ◽  
Douglas C. Crawford

A method has been developed that allows on-line measurement of the thickness of crystalline materials in the analytical electron microscope. Two-beam convergent beam electron diffraction (CBED) patterns are digitized from a JEOL 2000FX electron microscope into an Apple Macintosh II microcomputer via a Gatan #673 CCD Video Camera and an Imaging Systems Technology Video 1000 frame-capture board. It is necessary to know the lattice parameters of the sample since measurements are made of the spacing of the diffraction discs in order to calibrate the pattern. The sample thickness is calculated from measurements of the spacings of the fringes that are seen in the diffraction discs. This technique was pioneered by Kelly et al, who used the two-beam dynamic theory of MacGillavry relate the deviation parameter (Si) of the ith fringe from the exact Bragg condition to the specimen thickness (t) with the equation:Where ξg, is the extinction distance for that reflection and ni is an integer.


1993 ◽  
Vol 28 (11-12) ◽  
pp. 531-538 ◽  
Author(s):  
B. Teichgräber

A nitrification/denitrification process was applied to reject water treatment from sludge dewatering at Bottrop central sludge treatment facilities of the Emschergenossenschaft. On-line monitoring of influent and effluent turbidity, closed loop control of DO and pH, and on-line monitoring of nitrogen compounds were combined to a three level control pattern. Though on-line measurement of substrate and product showed substantial response time it could be used to operate nitrification/denitrification within process boundaries.


Author(s):  
Qiwen Jin ◽  
Xijiong Chen ◽  
Pei Li ◽  
Yonggang Zhou ◽  
Yingchun Wu ◽  
...  

2006 ◽  
Author(s):  
Yongcai Yang ◽  
Junsan Ma ◽  
Rimin Pan ◽  
Xiang Yu

Sign in / Sign up

Export Citation Format

Share Document