Generalised scalable fault dependent time invariant state space model for large interconnected power systems

Author(s):  
S. Saha ◽  
M. Aldeen
1998 ◽  
Vol 37 (12) ◽  
pp. 149-156 ◽  
Author(s):  
Carl-Fredrik Lindberg

This paper contains two contributions. First it is shown, in a simulation study using the IAWQ model, that a linear multivariable time-invariant state-space model can be used to predict the ammonium and nitrate concentration in the last aerated zone in a pre-denitrifying activated sludge process. Secondly, using the estimated linear model, a multivariable linear quadratic (LQ) controller is designed and used to control the ammonium and nitrate concentration.


2008 ◽  
Vol 100 (5) ◽  
pp. 2537-2548 ◽  
Author(s):  
Eric Zarahn ◽  
Gregory D. Weston ◽  
Johnny Liang ◽  
Pietro Mazzoni ◽  
John W. Krakauer

Adaptation of the motor system to sensorimotor perturbations is a type of learning relevant for tool use and coping with an ever-changing body. Memory for motor adaptation can take the form of savings: an increase in the apparent rate constant of readaptation compared with that of initial adaptation. The assessment of savings is simplified if the sensory errors a subject experiences at the beginning of initial adaptation and the beginning of readaptation are the same. This can be accomplished by introducing either 1) a sufficiently small number of counterperturbation trials (counterperturbation paradigm [ CP]) or 2) a sufficiently large number of zero-perturbation trials (washout paradigm [ WO]) between initial adaptation and readaptation. A two-rate, linear time-invariant state-space model (SSMLTI,2) was recently shown to theoretically produce savings for CP. However, we reasoned from superposition that this model would be unable to explain savings for WO. Using the same task (planar reaching) and type of perturbation (visuomotor rotation), we found comparable savings for both CP and WO paradigms. Although SSMLTI,2 explained some degree of savings for CP it failed completely for WO. We conclude that for visuomotor rotation, savings in general is not simply a consequence of LTI dynamics. Instead savings for visuomotor rotation involves metalearning, which we show can be modeled as changes in system parameters across the phases of an adaptation experiment.


Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 3 ◽  
Author(s):  
Eduardo Camacho ◽  
Antonio Gallego ◽  
Adolfo Sanchez ◽  
Manuel Berenguel

Model predictive control has been demonstrated to be one of the most efficient control techniques for solar power systems. An incremental offset-free state-space Model Predictive Controller (MPC) is developed for the Fresnel collector field located at the solar cooling plant installed on the roof of the Engineering School of Sevilla. A robust Luenberger observer is used for estimating the states of the plant which cannot be measured. The proposed strategy is tested on a nonlinear distributed parameter model of the Fresnel collector field. Its performance is compared to that obtained with a gain-scheduling generalized predictive controller. A real test carried out at the real plant is presented, showing that the proposed strategy achieves a very good performance.


2011 ◽  
Vol 219-220 ◽  
pp. 986-989
Author(s):  
Ke Luo ◽  
Hong Li Lv

An output prediction method based on state space model is proposed to overcome the poor reliability of the prediction method that does not use system model. The open-loop state observer is established based on the system state space model. Then the output prediction model is built in which the prediction error is used as input and a correction module is also contained. The module is used to correct the prediction error, and then the current predicted output can be obtained by the model from the delayed output. At last, a wide-area damping controller in power systems based on output prediction is designed to verify the effectiveness of the method.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4150
Author(s):  
Lluís Monjo ◽  
Luis Sainz ◽  
Juan José Mesas ◽  
Joaquín Pedra

Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into AC networks. Simultaneously, concerns regarding the stability of PV power systems are increasing. Converters reduce the damping of grid-connected converter systems, leading to instability. Several studies have analyzed the stability and dynamics of qZSI, although the characterization of qZSI-PV system dynamics in order to study transient interactions and stability has not yet been properly completed. This paper contributes a small-signal, state-space-averaged model of qZSI-PV systems in order to study these issues. The model is also applied to investigate the stability of PV power systems by analyzing the influence of system parameters. Moreover, solutions to mitigate the instabilities are proposed and the stability is verified using PSCAD time domain simulations.


Sign in / Sign up

Export Citation Format

Share Document