Condensation heat transfer and multi-phase pressure drop of CO2 near the critical point in a printed circuit heat exchanger

2019 ◽  
Vol 129 ◽  
pp. 1206-1221 ◽  
Author(s):  
Seong Jun Bae ◽  
Jinsu Kwon ◽  
Seong Gu Kim ◽  
In-woo Son ◽  
Jeong Ik Lee
Author(s):  
Ting Ma ◽  
Pan Zhang ◽  
Jie Lian ◽  
Hanbing Ke ◽  
Wei Wang ◽  
...  

Abstract The main cryogenic heat exchanger is a core piece of equipment in the liquefaction of natural gas. The printed circuit heat exchanger is gradually becoming a primary choice for the main cryogenic heat exchanger, because it has good pressure resistance, high efficiency, and compactness. In this work, a numerical simulation is conducted to examine the local flow and heat transfer characteristics of natural gas in the printed circuit heat exchanger during trans-critical liquefaction. It is found that the heat flux density reaches a minimum value and the heat transfer is the worst when the temperature difference between the hot and cold sides is the smallest. Owing to the large variations in physical properties of trans-critical natural gas, the local pressure drop exhibits an upward parabolic shape along the flow direction, and the pressure drop reaches a minimum value near the pseudo-critical point. Finally, the friction factor and heat transfer correlations for natural gas during trans-critical liquefaction are fitted.


Author(s):  
Suriyan Laohalertdecha ◽  
Somchai Wongwises

The effects of pitch and depth on the condensation heat transfer of R-134a flowing inside corrugated tubes are experimentally investigated. The test section is a horizontal tube-in-tube heat exchanger. The refrigerant flows in the inner tube and the water flows in the annulus. The length of heat exchanger is 2 m. A smooth tube and corrugated tubes having inner diameters of 8.7 mm are used as an inner tube. The corrugation pitches used in this study are 5.08, 6.35, and 8.46 mm. Similarly, the corrugation depths are 1, 1.25, and 1.5 mm. The effects of corrugation pitch and depth on tube wall temperature, heat transfer coefficient and frictional pressure drop are discussed. The results illustrate that the maximum heat transfer coefficient and frictional pressure drop obtained from the corrugated tube are up to 50% and 70% higher than those obtained from the smooth tube, respectively.


Author(s):  
Alan Kruizenga ◽  
Mark Anderson ◽  
Roma Fatima ◽  
Michael Corradini ◽  
Aaron Towne ◽  
...  

The increasing importance of improving efficiency and reducing capital costs has lead to significant work studying advanced Brayton cycles for high temperature energy conversion. Using compact, highly efficient, diffusion-bonded heat exchangers for the recuperators, has been a noteworthy improvement in the design of advanced carbon dioxide Brayton Cycles. These heat exchangers will operate near the pseudocritical point of carbon dioxide, making use of the drastic variation of the thermo-physical properties. This paper focuses on the experimental measurements of heat transfer under cooling conditions, as well as pressure drop characteristics within a prototypic printed circuit heat exchanger. Studies utilize type-316 stainless steel, nine channel, semi-circular test section, and supercritical carbon dioxide serves as the working fluid throughout all experiments. The test section channels have a hydraulic diameter of 1.16mm and a length of 0.5m. The mini-channels are fabricated using current chemical etching technology, emulating techniques used in current diffusion bonded printed circuit heat exchanger manufacturing. Local heat transfer values were determined using measured wall temperatures and heat fluxes over a large set of experimental parameters that varied system pressure, inlet temperature, and mass flux. Experimentally determined heat transfer coefficients and pressure drop data are compared to correlations and earlier data available in literature. Modeling predictions using the CFD package FLUENT are included to supplement experimental data. All nine channels were modeled using known inlet conditions and measured wall temperatures as boundary conditions. The FLUENT results show excellent agreement in total power removal for the near pseudocritical region, as well as regions where carbon dioxide is a high or low density fluid.


2016 ◽  
Vol 62 (16) ◽  
pp. 1788-1794 ◽  
Author(s):  
WenXiao CHU ◽  
XiongHui LI ◽  
Ting MA ◽  
Min ZENG ◽  
QiuWang WANG

Sign in / Sign up

Export Citation Format

Share Document