CeO2 quantum dots modified electrode for detecting hydrogen peroxide

2019 ◽  
Vol 101 ◽  
pp. 62-68 ◽  
Author(s):  
Yaping Wang ◽  
Junchao Qian ◽  
Zhigang Chen ◽  
Chencheng Wang ◽  
Chengbao Liu ◽  
...  
Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3368 ◽  
Author(s):  
Kefilwe Mokwebo ◽  
Oluwatobi Oluwafemi ◽  
Omotayo Arotiba

We report the preparation of poly (propylene imine) dendrimer (PPI) and CdTe/CdSe/ZnSe quantum dots (QDs) as a suitable platform for the development of an enzyme-based electrochemical cholesterol biosensor with enhanced analytical performance. The mercaptopropionic acid (MPA)-capped CdTe/CdSe/ZnSe QDs was synthesized in an aqueous phase and characterized using photoluminescence (PL) spectroscopy, ultraviolet-visible (UV-Vis) spectroscopy, transmission electron microscopy (TEM), X-ray power diffraction (XRD), energy dispersive X-ray (EDX) spectroscopy. The absorption and emission maxima of the QDs red shifted as the reaction time and shell growth increased, indicating the formation of CdTe/CdSe/ZnSe QDs. PPI was electrodeposited on a glassy carbon electrode followed by the deposition (by deep coating) attachment of the QDs onto the PPI dendrimer modified electrode using 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC), and N-hydroxysuccinimide (NHS) as a coupling agent. The biosensor was prepared by incubating the PPI/QDs modified electrode into a solution of cholesterol oxidase (ChOx) for 6 h. The modified electrodes were characterized by voltammetry and impedance spectroscopy. Since efficient electron transfer process between the enzyme cholesterol oxidase (ChOx) and the PPI/QDs-modified electrode was achieved, the cholesterol biosensor (GCE/PPI/QDs/ChOx) was able to detect cholesterol in the range 0.1–10 mM with a detection limit (LOD) of 0.075 mM and sensitivity of 111.16 μA mM−1 cm−2. The biosensor was stable for over a month and had greater selectivity towards the cholesterol molecule.


2019 ◽  
Vol 58 (21) ◽  
pp. 7040-7044 ◽  
Author(s):  
Henggang Wang ◽  
Zhenguang Wang ◽  
Yuan Xiong ◽  
Stephen V. Kershaw ◽  
Tianzi Li ◽  
...  

2019 ◽  
Vol 31 (5) ◽  
pp. 851-857 ◽  
Author(s):  
Sayed Tayyab Raza Naqvi ◽  
Bahareh Shirinfar ◽  
Dilshad Hussain ◽  
Saadat Majeed ◽  
Muhammad Naeem Ashiq ◽  
...  

Sensors ◽  
2019 ◽  
Vol 19 (22) ◽  
pp. 4977 ◽  
Author(s):  
Hong Dinh Duong ◽  
Jong Il Rhee

In this study, carboxyl group functionalized-CdSe/ZnS quantum dots (QDs) and aminofluorescein (AF)-encapsulated polymer particles were synthesized and immobilized to a sol–gel mixture of glycidoxypropyl trimethoxysilane (GPTMS) and aminopropyl trimethoxysilane (APTMS) for the fabrication of a hydrogen peroxide-sensing membrane. CdSe/ZnS QDs were used for the redox reaction of hydrogen peroxide (H2O2) via a reductive pathway by transferring electrons to the acceptor that led to fluorescence quenching of QDs, while AF was used as a reference dye. Herein, the ratiometric fluorescence intensity of CdSe/ZnS QDs and AF was proportional to the concentration of hydrogen peroxide. The fluorescence membrane (i.e., QD–AF membrane) could detect hydrogen peroxide in linear detection ranges from 0.1 to 1.0 mM with a detection limit (LOD) of 0.016 mM and from 1.0 to 10 mM with an LOD of 0.058 mM. The sensitivity of the QD–AF membrane was increased by immobilizing horseradish peroxidase (HRP) over the surface of the QD–AF membrane (i.e., HRP–QD–AF membrane). The HRP–QD–AF membrane had an LOD of 0.011 mM for 0.1–1 mM H2O2 and an LOD of 0.068 mM for 1–10 mM H2O2. It showed higher sensitivity than the QD–AF membrane only, although both membranes had good selectivity. The HRP–QD–AF membrane could be applied to determine the concentration of hydrogen peroxide in wastewater, while the QD–AF membrane could be employed for the detection of α-ketobutyrate.


Sign in / Sign up

Export Citation Format

Share Document