scholarly journals TCT-326 In Vitro Performance of Thermoformed Polymeric Transcatheter Heart Valves

2021 ◽  
Vol 78 (19) ◽  
pp. B133
Author(s):  
Hieu Bui ◽  
Susan James ◽  
Lakshmi Dasi
1973 ◽  
Vol 29 (03) ◽  
pp. 694-700 ◽  
Author(s):  
Paul L. Rifkin ◽  
Marjorie B. Zucker

SummaryDipyridamole (Persantin) is reported to prolong platelet survival and inhibit embolism in patients with prosthetic heart valves, but its mechanism of action is unknown. Fifty jxM dipyridamole failed to reduce the high percentage of platelets retained when heparinized human blood was passed through a glass bead column, but prolonged the inhibition of retention caused by disturbing blood in vitro. Possibly the prostheses act like disturbance. Although RA 233 was as effective as dipyridamole in inhibiting the return of retention, it was less effective in preventing the uptake of adenosine into erythrocytes, and more active in inhibiting ADP-induced aggregation and release. Thus there is no simple relation between these drug effects.


2007 ◽  
Vol 55 (S 1) ◽  
Author(s):  
UA Stock ◽  
T Attmann ◽  
M Hartrumpf ◽  
RU Kuehnel ◽  
M Wendt ◽  
...  
Keyword(s):  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M.M Engelen ◽  
C Van Laer ◽  
M Jacquemin ◽  
C Vandenbriele ◽  
K Peerlinck ◽  
...  

Abstract Introduction Contact of blood with artificial surfaces such as mechanical support devices, catheters, and mechanical heart valves activates the contact activation (CA) pathway of coagulation. Furthermore, recent animal data and clinical studies suggest a more important contribution of CA in pathological thrombus formation in other cardiovascular diseases. Direct oral anticoagulants (DOACs) are recommended as first-line treatment in most patients who require long-term anticoagulation. However, because DOACs directly inhibit a single downstream coagulation factor (thrombin (fXIIa) or factor Xa (fXa)), it has been suggested that their efficacy could be reduced in the presence of strong activation of the CA pathway as compared to anticoagulants that target multiple, more upstream located coagulation factors. Purpose To compare the efficacy of a DOAC (apixaban) and heparin to suppress thrombin generation in the presence of strong CA pathway activation. Methods Pooled platelet-poor plasma was spiked with either apixaban (dissolved in DMSO and PBS) or unfractionated heparin to achieve therapeutic plasma levels. SynthASil, a commercially available mixture of phospholipids and silica, was used to stimulate the CA pathway in two different dilutions (1–80 and 5–80). Downstream coagulation was accessed by Thrombin Generation Test using Thrombinoscope by Stago and associated Thrombin Calibrator (activity 640 nM). The endogenous thrombin potential (area under the thrombin generation curve; ETP), peak thrombin generation (PTG), time to peak (ttPeak) and time to start (ttStart) were accessed. Results With decreasing concentrations of apixaban, stimulation with the lower dose SynthASil reveals an increasing ETP and PTG. As expected, ttPeak and ttStart decreased. Even supratherapeutic levels of apixaban (i.e. 1120 ng/mL) could not inhibit thrombin from being generated, in striking contrast with UFH where no thrombin was formed. Using a five times higher dose of SynthASil showed comparable ETP for all concentrations of apixaban, allocated around the control value. PTG, however, slightly increased with decreasing concentrations of apixaban. ttPeak and ttStart slightly decreased. Except for the subtherapeutic UFH concentration of 0,114 IU/mL, no thrombin was generated with UFH. Conclusion UFH is more effective in inhibiting downstream thrombin generation compared to apixaban as a response to activation of the CA pathway in vitro. These findings could help explain why direct inhibitors were not able to show non-inferiority in patients with mechanical heart valves and support the development of specific CA pathway inhibitors for patients with conditions that activate the CA pathway. Thrombin generation curves Funding Acknowledgement Type of funding source: None


2005 ◽  
Vol 284-286 ◽  
pp. 581-584 ◽  
Author(s):  
Alejandro de Carlos ◽  
Jacinto P. Borrajo ◽  
Julia Serra ◽  
Pio González ◽  
Sara Liste ◽  
...  

The aim of this study was to test the in vitro cytotoxicity of wood-based biomorphic Silicon Carbide (SiC) ceramics, using MG-63 human osteoblast-like cells. This innovative material has been recently developed and it exhibits unique mechanical properties towards their application in biomedical technology. In the solvent extraction test the SiC ceramic extracts had almost no effect on cellular activity even at 100% concentration. A similar behaviour was found for Ti6Al4V and bioactive glass, used as reference materials. The results of the cell morphology and the cellular attachment response have also demonstrated that the in vitro performance of these biomorphic SiC ceramics is qualitatively comparable to that produced by titanium alloy and bioactive glass, which seems very promising.


Author(s):  
Raimond Grimberg ◽  
Adriana Savin ◽  
Shiu C. Chan ◽  
Rozina Steigmann ◽  
Lalita Udpa ◽  
...  

Prosthetic heart valves of the Bjork-Shiley Convexo-Concave (BSCC) type have long been used extensively in implants; however, there have been reports of cases where one component of the valves failed, leading to the demise of the patient. This paper presents a new method for noninvasive electromagnetic evaluation for this type of valve, using an eddy current transducer with orthogonal coils. In vitro experiments have shown that discontinuities of outlet strut with depths equal or larger than 0.4mm can be detected with a probability of detection (POD) of 86.4%, and in the case of discontinuities with depth equal or larger than 0.6mm with POD of 97%.


2006 ◽  
Vol 39 ◽  
pp. S306 ◽  
Author(s):  
L.P. Dasi ◽  
H. Simon ◽  
L. Ge ◽  
F. Sotiropoulos ◽  
A. Yoganathan

Sign in / Sign up

Export Citation Format

Share Document