scholarly journals 073_16772-H5 First Long-Term Redo Experiences With Cryo After Cryoballoon Ablation for Atrial Fibrillation: A Two-Year Follow-Up Registry

2017 ◽  
Vol 3 (10) ◽  
pp. S9-S10
Author(s):  
S.W. Westra ◽  
S.P.G. van Vugt ◽  
S. Sezer ◽  
R. Evertz ◽  
R.J. Beukema ◽  
...  
2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Karapet Davtyan ◽  
Victoria Shatakhtsyan ◽  
Hermine Poghosyan ◽  
Alexandr Deev ◽  
Alexey Tarasov ◽  
...  

Introduction. While several studies have compared the radiofrequency current (RFC) and cryoablation for the treatment of patients with atrial fibrillation (AF), no study has monitored the long-term outcomes with the usage of implantable loop recorders (ILRs). Methods. We enrolled 89 consecutive patients with nonvalvular paroxysmal AF (N=44 for RFC and N=45 for cryoballoon). The primary efficacy end point was the assessment of effectiveness for each group (RFC versus cryoballoon) when examining freedom from arrhythmia by monitoring with ECG, Holter, and implantable loop recoder (ILR). The primary safety end point compared rates of adverse events between both groups. The secondary efficacy end point examined the duration of the postablation blanking period from ILR retrieved data. Results. The mean age of the study population was 56.6±10.2 years, and the follow-up duration was 12 months. There were no differences in baseline patient characteristics between groups. At 12 months, the absolute effectiveness (measured by ILR) was 65.9% in the RFC group and 51.1% in the cryoballoon group (OR = 1.85; 95% CI: 0.79–4.35; p=0.157), and the clinical effectiveness (measured by ECG and Holter) was 81.8% in the RFC group and 55.6% in the cryoballoon group (OR = 3.6; 95% CI: 1.37–9.46; p=0.008). There was no difference in safety between both groups. Asymptomatic episodes were significantly more present in the RFC group as measured by ILRs (p<0.010). In cryoballoon group, arrhythmia episodes were recorded equally irrespective of the follow-up method (i.e., ECG and Holter versus ILR (p>0.010)). The blanking period does not seem to be as important in cryoballoon as compared to RFC. Conclusion. RFC and cryoballoon ablation had similar absolute effectiveness at 12 months. ECG and Holter were effective when assessing the efficacy of the cryoballoon ablation; however, in the RFC group, ILR was necessary to accurately assess long-term efficacy.


2014 ◽  
Vol 64 (16) ◽  
pp. C165
Author(s):  
Liu Jun ◽  
Ming Tang ◽  
Yan Kaufmann ◽  
Charalampos Kriatselis ◽  
Eckart Fleck ◽  
...  

QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O H M A Riad ◽  
T Wong ◽  
A N Ali ◽  
M T Ibrahim ◽  
M A Abdelhamid ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) has become the mainstay of catheter ablation of atrial fibrillation (AF). There are two commonly used methods to isolate the pulmonary veins, either point-by-point delivery of circumferential lesion sets around ipsilateral pulmonary veins using radiofrequency energy, or the application of the cryoballoon to the pulmonary vein antrum with occlusion of the vein ostium. The cryoballoon has proven to be a reliable alternative to radiofrequency ablation in acute and long-term freedom from AF. We describe our results using both modalities. Aim and Objectives to compare the safety and efficacy of cryoballoon (CB) ablation and radiofrequency (RF) ablation in treatment of paroxysmal atrial fibrillation. Patients and Methods Forty-four consecutive patients having paroxysmal AF underwent PVI using the second generation cryoballoon were compared to a retrospective cohort of 69 patients who had radiofrequency induced PVI, either by conventional RF catheter (n = 32), or a contact-force sensing-catheter (n = 37). The study took place at Ain Shams university hospitals and Royal Brompton & Harefield NHS trust. Patient data, procedural data and follow up data- at 3, 6 and 12 months- were collected and analysed. Recurrence was defined as documented AF or atrial arrhythmias with duration exceeding 30 seconds, either by 12 lead ECG or an ambulatory monitoring device. Results A total of 113 patients were studied. The mean age was 53.84 ± 15.01 for the CB group and 55.78 ± 14.84 for the RF group and females representing 40.9% vs 34.8% respectively. The mean procedural times in minutes were significantly less in the CB group (94.37 ± 39.32 vs 184.57 ± 88.19, p &lt; 0.0001), while the median fluoroscopy times were similar [30 (11.04 - 40) vs 37.25 (14.2 - 70), p = 0.172]. Procedural complications were comparable between the two groups (p = 0.06) with 1 patient (2.3%) having long term phrenic nerve paresis. At 1 year follow up, after an initial 90-day blanking period, recurrence rate of CB was similar to RF (27.3% vs 30.4% respectively, p = 0.719), the Kaplan Meier estimates of AF- free survival for a period of 1 year were comparable between both groups (log rank test, p = 0.606). Conclusion Cryoballoon is a feasible method for pulmonary vein isolation with similar success rates to radiofrequency ablation. Cryoballoon ablation is safe with shorter duration of the procedure.


EP Europace ◽  
2020 ◽  
Vol 22 (12) ◽  
pp. 1798-1804 ◽  
Author(s):  
Giuseppe Stabile ◽  
Saverio Iacopino ◽  
Roberto Verlato ◽  
Giuseppe Arena ◽  
Paolo Pieragnoli ◽  
...  

Abstract Aims The aims of this study were to determine the rate and the predictors of early recurrences of atrial fibrillation (ERAF) after cryoballoon (CB) ablation and to evaluate whether ERAF correlate with the long-term outcome. Methods and results Three thousand, six hundred, and eighty-one consecutive patients (59.9 ± 10.5 years, female 26.5%, and 74.3% paroxysmal AF) were included in the analysis. Atrial fibrillation recurrence, lasting at least 30 s, was collected during and after the 3-month blanking period. Three-hundred and sixteen patients (8.6%) (Group A) had ERAF during the blanking period, and 3365 patients (Group B) had no ERAF. Persistent AF and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of ERAF. After a mean follow-up of 16.8 ± 16.4 months, 923/3681 (25%) patients had at least one AF recurrence. The observed freedom from AF recurrence, at 24-month follow-up from procedure, was 25.7% and 64.8% in Groups A and B, respectively (P &lt; 0.001). ERAF, persistent AF, and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of AF. In a propensity score matching, the logistic model showed that ERAF 1 month after ablation are the best predictor of long-term AF recurrence (P = 0.042). Conclusion In patients undergoing CB ablation for AF, ERAF are rare and are a strong predictor of AF recurrence in the follow-up, above all when occur &gt;30 days after the ablation.


2017 ◽  
Vol 49 (1) ◽  
pp. 93-100 ◽  
Author(s):  
Ken Takarada ◽  
Ingrid Overeinder ◽  
Carlo de Asmundis ◽  
Erwin Stroker ◽  
Giacomo Mugnai ◽  
...  

Author(s):  
Ermengol Valles ◽  
Jesus Jimenez ◽  
Julio Martí-Almor ◽  
Jorge Toquero ◽  
Jose Ormaetxe ◽  
...  

Introduction: Cryoballoon ablation (CBA) has become a standard treatment for paroxysmal atrial fibrillation (PaAF) but limited data is available for outcomes in patients with persistent atrial fibrillation (PeAF). Methods: We analyzed the first 944 patients included in the Spanish Prospective Multi-center Observation Post-market Registry to compare characteristics and outcomes of patients undergoing CBA for PeAF versus PaAF. Results: A total of 944 patients (57.8±10.4 years; 70.1% male) with AF (27.9% persistent) were prospectively included from 25 centers. PeAF patients were more likely to have structural heart disease (67.7 vs 11.4%; p<0.001) and left atrium dilation (72.6 vs 43.3%; p<0.001). CBA of PeAF was less likely to be performed under general anesthesia (10.7 vs 22.2%; p<0.001), with an arterial line (32.2 vs 44.6%; p<0.001) and assisted transeptal puncture (11.9 vs 17.9%; p=0.025). During an application, PeAF patients had a longer time to -30°C (35.91±14.20 vs 34.93±12.87 sec; p=0.021) and a colder balloon nadir temperature during vein isolation (-35.04±9.58 vs -33.61±10.32ºC; p=0.004), but received fewer bonus freeze applications (30.7 vs 41.1%; p<0.001). There were no differences in acute pulmonary vein isolation and procedure-related complications. Overall, 76.7% of patients were free from AF recurrences at 15-month follow-up (78.9% in PaAF vs. 70.9% in PeAF; p=0.09). Conclusions: Patients with PeAF have a more diseased substrate, and CBA procedures performed in such patients were more simplified, although longer/colder freeze applications were often applied. The acute efficacy/safety profile of CBA was similar between PaAF and PeAF patients, but long-term results were better in PaAF patients.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Luigi Sciarra ◽  
Saverio Iacopino ◽  
Giuseppe Arena ◽  
Claudio Tondo ◽  
Paolo Pieragnoli ◽  
...  

Background. The real-world efficacy and safety of atrial fibrillation (AF) ablation in particularly young and elderly patients are still under debate. The aim of the analysis was to investigate the effect of age on the efficacy and safety of cryoballoon ablation (CBA). Methods. 2,534 patients underwent pulmonary vein isolation (PVI) by way of CBA for paroxysmal or persistent drug-resistant and symptomatic AF. The population was divided into age quartiles for evaluation, including (1) <53 years, (2) ≥53 and <61 years, (3) ≥61 and <67 years, and (4) ≥67 years. Furthermore, outcomes were analyzed in patients <41 years, ≥41 and ≤74, and >74 years old. Procedural data and complications were collected, and atrial fibrillation recurrences were evaluated during follow-up. Results. Procedural-related complications (4.1%) were similar in the four subgroups according to age. At the 12-month follow-up, freedom from AF recurrence was 79.2%, 77.4%, 76.8%, and 75.2% ( p = 0.21 ), respectively (with increasing age). At 24-month follow-up, similar incidences of AF recurrence were observed in the four subgroups. When the sample was arbitrarily divided into the three age groups, a higher rate of recurrence was observed in older patients with regard to long-term follow-up (freedom from AF recurrence was 71.8% and 40.9%, respectively, at 12 and 24-month follow-up). In the univariate and multivariate analysis, age did not result in a significant predictor of AF recurrence during follow-up; however, a trend toward higher AF recurrences rates in patients ≥67 years was observed. Conclusion. The data demonstrated a high degree of safety during CBA across all patient ages. Procedural performance and complications were similar between different ages; AF recurrences seem to be more frequent in patients over 74 years.


Author(s):  
Nico Erhard ◽  
Andreas Metzner ◽  
Thomas Fink

Abstract Background and objectives Catheter ablation of atrial fibrillation (AF) has become a well-established and widely used therapy, with pulmonary vein isolation (PVI) being the key modality of ablation. However, arrhythmia recurrences after PVI are common, with a relevant number of patients undergoing repeat ablation. Arrhythmia recurrence after PVI may vary regarding time point and mode of recurrence. While early arrhythmia recurrences of AF after PVI are mostly found to be the product of electrical reconnection of the pulmonary veins, the exact mechanisms of very late arrhythmia recurrence, occurring later than 12 months after successful PVI, remain unclear. This review provides an overview on the current evidence on time point and mechanisms of arrhythmia recurrence after PVI focussing on late arrhythmia recurrence. Recent findings The incidence of late arrhythmia recurrence after PVI can lie at a rate of up to 30% according to long-term follow-up studies. Mechanisms of recurrence include electrical reconnection of previously isolated pulmonary veins and development of atrial fibrosis. The use of cryoballoon ablation is likely to be more effective in reducing late arrhythmia recurrences compared to radiofrequency ablation. Novel scores such as the MB-LATER score or the APPLE score may become useful tools in predicting arrhythmia recurrence after PVI. Results and conclusion Late arrhythmia recurrence after PVI is common and leads to a relevant impairment of long-term success. Relevant data are currently limited and exact mechanisms of arrhythmia recurrence remain unclear. Further studies are needed to elucidate pathogenetic mechanisms of late arrhythmia recurrence after PVI in order to improve treatment strategies.


Sign in / Sign up

Export Citation Format

Share Document