scholarly journals Measuring time-domain spectral induced polarization in the on-time: decreasing acquisition time and increasing signal-to-noise ratio

2015 ◽  
Vol 123 ◽  
pp. 316-321 ◽  
Author(s):  
Per-Ivar Olsson ◽  
Torleif Dahlin ◽  
Gianluca Fiandaca ◽  
Esben Auken
Author(s):  
D. C. Joy ◽  
R. D. Bunn

The information available from an SEM image is limited both by the inherent signal to noise ratio that characterizes the image and as a result of the transformations that it may undergo as it is passed through the amplifying circuits of the instrument. In applications such as Critical Dimension Metrology it is necessary to be able to quantify these limitations in order to be able to assess the likely precision of any measurement made with the microscope.The information capacity of an SEM signal, defined as the minimum number of bits needed to encode the output signal, depends on the signal to noise ratio of the image - which in turn depends on the probe size and source brightness and acquisition time per pixel - and on the efficiency of the specimen in producing the signal that is being observed. A detailed analysis of the secondary electron case shows that the information capacity C (bits/pixel) of the SEM signal channel could be written as :


2001 ◽  
Vol 685 ◽  
Author(s):  
M. Fernandes ◽  
Yu. Vygranenko ◽  
J. Martins ◽  
M. Vieira

AbstractWe suggest to enhance the performance of image acquisition systems based on large area amorphous silicon based sensors by optimizing the readout parameters such as the intensity and cross-section of scanner beam, acquisition time and bias conditions. The main output device characteristics as image responsivity, signal to noise ratio and spatial resolution were analyzed in open circuit, short circuit and photodiode modes. The result show that the highest signal to noise ratio and best dark to bright ratio can be achieved in short circuit mode.It was shown that the sensor resolution is related to the basic device parameters and, in practice, limited by the acquisition time and scanning beam properties. The scanning beam spot size limits the resolution due to the overlapping of dark and illuminated zones leading to a blurring effect on the final image and a consequent degradation in the resolution.


2019 ◽  
Vol 9 (7) ◽  
pp. 1312 ◽  
Author(s):  
Tiago Bueno Moraes ◽  
Tatiana Monaretto ◽  
Luiz Colnago

This review discusses the theory and applications of the Continuous Wave Free Precession (CWFP) sequence in low-field, time-domain nuclear magnetic resonance (TD-NMR). CWFP is a special case of the Steady State Free Precession (SSFP) regime that is obtained when a train of radiofrequency pulses, separated by a time interval Tp shorter than the effective transverse relaxation time (T2*), is applied to a sample. Unlike regular pulsed experiments, in the CWFP regime, the amplitude is not dependent on T1. Therefore, Tp should be as short as possible (limited by hardware). For Tp < 0.5 ms, thousands of scans can be performed per second, and the signal to noise ratio can be enhanced by more than one order of magnitude. The amplitude of the CWFP signal is dependent on T1/T2; therefore, it can be used in quantitative analyses for samples with a similar relaxation ratio. The time constant to reach the CWFP regime (T*) is also dependent on relaxation times and flip angle (θ). Therefore, T* has been used as a single shot experiment to measure T1 using a low flip angle (5°) or T2, using θ = 180°. For measuring T1 and T2 simultaneously in a single experiment, it is necessary to use θ = 90°, the values of T* and M0, and the magnitude of CWFP signal |Mss|. Therefore, CWFP is an important sequence for TD-NMR, being an alternative to the Carr-Purcell-Meiboom-Gill sequence, which depends only on T2. The use of CWFP for the improvement of the signal to noise ratio in quantitative and qualitative analyses and in relaxation measurements are presented and discussed.


2012 ◽  
Vol 68 (6) ◽  
pp. 1983-1993 ◽  
Author(s):  
Esben Plenge ◽  
Dirk H. J. Poot ◽  
Monique Bernsen ◽  
Gyula Kotek ◽  
Gavin Houston ◽  
...  

1989 ◽  
Vol 30 (4) ◽  
pp. 343-348 ◽  
Author(s):  
S. Holtås ◽  
F. Ståhlberg ◽  
H. Nilsson ◽  
E.-M. Larsson ◽  
A. Ericsson

The influence of flip angle and TR on signal to noise ratio and contrast between cerebrospinal fluid (CSF) and cord was evaluated in cervical spine imaging in 5 volunteers, using gradient echo technique. All experiments were performed on a 0.3 tesla Fonar β-3000 M scanner using solenoidal surface coils. The most useful sequence was considered to be TR/TE=300/12 ms and 10° flip angle. This sequence provided images with a ‘myelographic appearance’ with good delineation of cord, CSF and epidural space. The grey and white matter was also regularly visualized. The acquisition time was considerably shorter than would have been necessary if a long TR/TE spin echo sequence had been used to obtain the same contrast pattern and the sequence was not as sensitive to motion as was the spin echo sequence. The sequence was also evaluated in 10 patients with degenerative disease and in 5 with lesions in the cord. The gradient echo sequence was found to be equal to or better than short and long TR/TE spin echo sequences in demonstrating narrowing of the spinal canal and cord lesions. The drawback is the limited signal to noise ratio.


IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 167089-167098
Author(s):  
Mohamed M. Elgaud ◽  
Mohd Saiful Dzulkefly Zan ◽  
Abdulfatah Abushagur Ghaith ◽  
Ahmad Ashrif A. Bakar ◽  
Norhana Arsad ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document