Behaviour and design of concrete-filled spiral-welded stainless-steel tube short columns under concentric and eccentric axial compression loading

2019 ◽  
Vol 158 ◽  
pp. 522-546 ◽  
Author(s):  
Yasoja Gunawardena ◽  
Farhad Aslani
2021 ◽  
Vol 227 ◽  
pp. 111416
Author(s):  
Tuan Trung Le ◽  
Vipulkumar Ishvarbhai Patel ◽  
Qing Quan Liang ◽  
Phat Huynh

2018 ◽  
Vol 80 (2) ◽  
Author(s):  
Azrul Abd Mutalib ◽  
Mohamed Hamza Mussa ◽  
Khaleel Mohammad Khaleel Abusal

Recently, the concrete filled stainless steel tubes (CFSST) columns are widely applied in modern construction due to its aesthetic appearance, high corrosion resistant and less construction cost. The current study aims to evaluate the behavior of CFSST column with square hollow section (SHS) numerically under axial compressive load by using ABAQUS software. A good consistency had achieved between the numerical and experimental test results in terms of load-displacement behaviour and ultimate strength with a maximum difference equal to 2%. Intensive parametric studies had been conducted to determine the effects of stainless steel tubes and concrete properties on the ultimate load capacity of CFSST column. The results proved that the stainless steel tube thickness (t) capable to increase the strength of column by143.59% at t = 10 mm as compared with t = 2 mm, whereas a slight effect had observed for the variation of stainless steel proof stress ( ). On the other hand, the higher values of concrete strength (fc′) obviously reduced the lateral expansion of CFSST column at initial load and led to increase the ultimate load capacity by 34.18 % at fc′ = 80 MPa as compared with  fc′ = 30 MPa. Furthermore, the design strengths calculated according to the Eurocode 4 for concrete filled steel tube (CFST) column appeared a good agreement with the numerical results within an average difference value 2.49%, hence, it could consider as the most rational design method to determine the ultimate strength of CFSST column.


2019 ◽  
Vol 8 (1) ◽  
pp. 600-618 ◽  
Author(s):  
Qingjie Lin ◽  
Yu Chen ◽  
Chao Liu

AbstractExperimental research on circular nano-silica concrete filled stainless steel tube (C-CFSST) stub columns after being exposed to freezing and thawing is carried out in this paper. All of forty specimens were tested in this paper, including nine C-CFSST specimens at normal temperature, 28 short columns of C-CFSST for freeze-thaw treatment and three circular hollow stainless steel stub columns. The failure mode, load-displacement curves, load-strain curves and load-bearing capacity were obtained and analyzed in this paper. The main parameters explored in the test include the number of freeze-thaw cycles (N=0, N=50, N=75, and N=100), wall thickness (T=1.0mm, T=1.2mm, T=1.5mm) andnano-silica concrete strength (fc=20MPa, fc=30MPa, fc=40MPa). The result shows that C-CFSST short columns at normal temperature and subjected to freezing and thawing follow similar failure mode. The effect of freeze-thaw cycles (N) of 50 on bearing capacity of C-CFSST column was maximal, and then the influence of N on the bearing capacity of specimens was small when N reached to 75, finally the effect of N on bearing capacity of C-CFSST column was large when N reached to 100. The bearing capacity of C-CFSST columns increases with increasing wall thickness. In addition, the loss percentage of bearing capacity of specimens (fc=40MPa) for freeze-thaw treatment is maximal, and the loss percentage of bearing capacity of specimens (fc=30MPa) for freeze-thaw treatment is minimal. According to the test results, this paper proposed a formula to calculate the bearing capacity of C-CFSST short columns for freeze-thaw treatment.


Author(s):  
A. E. Gorodetskii ◽  
V. L. Bukhovets ◽  
R. Kh. Zalavutdinov ◽  
A. P. Zakharov

Sign in / Sign up

Export Citation Format

Share Document