A computer based solution to check the drop in milk outlet temperature due to fouling in a tubular heat exchanger

2005 ◽  
Vol 71 (2) ◽  
pp. 133-142 ◽  
Author(s):  
P.K. Nema ◽  
A.K. Datta
2013 ◽  
Vol 694-697 ◽  
pp. 2195-2199
Author(s):  
Qiao Ling Ji ◽  
Cong He ◽  
Wei Min Qi ◽  
Jian Kang Zhu

The paper deals with the problem of controlling the outlet temperature of a tubular heat exchanger system by means of flow pressure. The usual industrial system behavior must precisely be modeled and appropriate control action needs to be obtained based on novel techniques. A new multiple models control strategy using the well-known linear generalized predictive control (LGPC) scheme has been proposed in this paper. Then the best model of the system is accurately identified by an intelligent decision mechanism (IDM) which is organized based on both new recursive weight generator and fuzzy adaptive Kalman filter approaches. Simulations are all done and the results are also compared with those obtained using a nonlinear GPC (NLGPC) approach that is realized based on the Wiener model of the system. The results can verify the validity of the proposed control scheme.


2018 ◽  
Vol 91 (6) ◽  
pp. 1486-1495
Author(s):  
E. A. Pitsukha ◽  
Yu. S. Teplitskii ◽  
A. R. Roslik ◽  
É. K. Buchilko

1997 ◽  
Vol 33 (4) ◽  
pp. 377-380 ◽  
Author(s):  
O. K. Krasnikova ◽  
L. P. Komarova ◽  
T. S. Mishchenko

Author(s):  
Claudia Ruiz-Mercado ◽  
Arturo Pacheco-Vega ◽  
Kevin Peters

We develop a fuzzy rule based controller to perform on-line temperature control of a concentric-tubes heat exchanger facility. The rules were derived from dynamical values of the mass flow rates and fluid temperatures in the heat exchanger. The controller was embedded in a closed-loop single-input single-output system to control the outlet temperature of the cold fluid. The controller was constructed in two stages, the difference between them being the amount of information provided to the controller. To validate the fuzzy controller two sets of tests were carried out for maintaining a constant value of the outlet temperature under different perturbations. Results from this analysis demonstrate that the fuzzy-based controller is able to achieve control of the system, and that the information about the system provided to it is important in terms of accuracy and efficiency.


2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


2018 ◽  
Vol 192 ◽  
pp. 02062
Author(s):  
Pattarapan Tongyote ◽  
Pongjet Promvonge ◽  
Nattawoot Depaiwa ◽  
Withada Jedsadaratanachai

The paper presents an experimental heat transfer enhancement study in a tubular heat exchanger fitted with delta-winglets. The experimental work was conducted by varying the airflow rate in the test tube having a constant wall heat-flux for turbulent regime, Reynolds number (Re) from 5200 to 23,000. Effects of three pitch ratios (PR=P/D=1.5, 2.0 and 3.0) and two attack angles, α = 45° and 60°, of the winglets at a single blockage ratio (BR=b/D = 0.15) on thermal characteristics are examined. The experimental results show that the winglet-inserted tube yields, respectively, the heat transfer, friction factor and thermal performance in the form of TEF around 1.99–4.08, 4.9–14.3 times higher than the plain tube and 0.85–1.85, depending on the operating condition.


Sign in / Sign up

Export Citation Format

Share Document