Soil water content determination with cosmic-ray neutron sensor: Correcting aboveground hydrogen effects with thermal/fast neutron ratio

2016 ◽  
Vol 540 ◽  
pp. 923-933 ◽  
Author(s):  
Zhengchao Tian ◽  
Zizhong Li ◽  
Gang Liu ◽  
Baoguo Li ◽  
Tusheng Ren
2016 ◽  
Vol 15 (7) ◽  
pp. vzj2016.01.0004 ◽  
Author(s):  
Min Li ◽  
Bing Cheng Si ◽  
Wei Hu ◽  
Miles Dyck

2015 ◽  
Vol 12 (9) ◽  
pp. 9813-9864 ◽  
Author(s):  
I. Heidbüchel ◽  
A. Güntner ◽  
T. Blume

Abstract. Cosmic ray neutron sensors (CRS) are a promising technique to measure soil moisture at intermediate scales. To convert neutron counts to average volumetric soil water content a simple calibration function can be used (the N0-calibration of Desilets et al., 2010). This calibration function is based on soil water content derived directly from soil samples taken within the footprint of the sensor. We installed a CRS in a mixed forest in the lowlands of north-eastern Germany and calibrated it 10 times throughout one calendar year. Each calibration with the N0-calibration function resulted in a different CRS soil moisture time series, with deviations of up to 0.12 m3 m-3 for individual values of soil water content. Also, many of the calibration efforts resulted in time series that could not be matched with independent in situ measurements of soil water content. We therefore suggest a new calibration function with a different shape that can vary from one location to another. A two-point calibration proved to be adequate to correctly define the shape of the new calibration function if the calibration points were taken during both dry and wet conditions covering at least 50 % of the total range of soil moisture. The best results were obtained when the soil samples used for calibration were linearly weighted as a function of depth in the soil profile and non-linearly weighted as a function of distance from the CRS, and when the depth-specific amount of soil organic matter and lattice water content was explicitly considered. The annual cycle of tree foliation was found to be a negligible factor for calibration because the variable hydrogen mass in the leaves was small compared to the hydrogen mass changes by soil moisture variations. Finally, we provide a best practice calibration guide for CRS in forested environments.


2016 ◽  
Vol 20 (3) ◽  
pp. 1269-1288 ◽  
Author(s):  
Ingo Heidbüchel ◽  
Andreas Güntner ◽  
Theresa Blume

Abstract. Measuring soil moisture with cosmic-ray neutrons is a promising technique for intermediate spatial scales. To convert neutron counts to average volumetric soil water content a simple calibration function can be used (the N0-calibration of Desilets et al., 2010). The calibration is based on soil water content derived directly from soil samples taken within the footprint of the sensor. We installed a cosmic-ray neutron sensor (CRS) in a mixed forest in the lowlands of north-eastern Germany and calibrated it 10 times throughout one calendar year. Each calibration with the N0-calibration function resulted in a different CRS soil moisture time series, with deviations of up to 0.1 m3 m−3 (24 % of the total range) for individual values of soil water content. Also, many of the calibration efforts resulted in time series that could not be matched with independent in situ measurements of soil water content. We therefore suggest a modified calibration function with a different shape that can vary from one location to another. A two-point calibration was found to effectively define the shape of the modified calibration function if the calibration points were taken during both dry and wet conditions spanning at least half of the total range of soil moisture. The best results were obtained when the soil samples used for calibration were linearly weighted as a function of depth in the soil profile and nonlinearly weighted as a function of distance from the CRS, and when the depth-specific amount of soil organic matter and lattice water content was explicitly considered. The annual cycle of tree foliation was found to be a negligible factor for calibration because the variable hydrogen mass in the leaves was small compared to the hydrogen mass changes by soil moisture variations. As a final point, we provide a calibration guide for a CRS in forested environments.


2013 ◽  
Vol 49 (9) ◽  
pp. 5778-5791 ◽  
Author(s):  
H. R. Bogena ◽  
J. A. Huisman ◽  
R. Baatz ◽  
H.-J. Hendricks Franssen ◽  
H. Vereecken

Sign in / Sign up

Export Citation Format

Share Document