Influence of internal defects of semi grouted sleeve connections on the seismic performance of precast monolithic concrete columns

2022 ◽  
pp. 104009
Author(s):  
Fanrong Li ◽  
Donato Abruzzese ◽  
Gabriele Milani ◽  
Shengcai Li
2021 ◽  
Author(s):  
Shengcai Li ◽  
Shengxiang Shi ◽  
Zhongchen Zhou

In order to evaluate the influence of internal defects of semi-grouting sleeve connection on seismic performance of assembled monolithic columns, four specimens of assembled monolithic concrete column with semi grouting sleeve connecting reinforcement bar were fabricated with 10%, 20%, 30% internal defects. The test results show that (1) the assembled columns are all damaged by bending, the grouting layer of the assembled column can be pulled apart easily and the cracks develop more closely on the upper part of the sleeve; (2) the larger the internal defects in the sleeve, the less the cracks on the column, and the less sufficient the cracks development; (3) the seismic energy dissipation capacity of the column without defect is better than that of the defective columns.


2010 ◽  
Vol 163-167 ◽  
pp. 2267-2273 ◽  
Author(s):  
Hong Ying Dong ◽  
Wan Lin Cao ◽  
Jian Wei Zhang

Two 1/6 scale core walls, including one RC core wall with steel tube-reinforced concrete columns and concealed steel trusses and one conventional RC core wall, were tested under eccentric horizontal cyclic loading. The load-capacity, ductility, hysteresis characteristics, stiffness, stiffness deterioration process, energy dissipation and damage characteristics of the two specimens were compared and discussed in this paper. It shows that the seismic performance of the RC core walls under combined action could be improved by setting the concealed steel trusses in the walls and using the steel tube-reinforced concrete columns as the boundary elements.


2018 ◽  
Vol 2018 ◽  
pp. 1-19
Author(s):  
Chunyi Yu ◽  
Hua Ma ◽  
Yongping Xie ◽  
Zhenbao Li ◽  
Zhenyun Tang

The size effect on the seismic performance of conventional reinforced concrete columns has been observed in terms of flexural failure and shear failure. Under earthquake loading, slender columns experience flexural failure, and short columns experience flexure-shear failure and shear failure. However, the effect of section size on the seismic performance of high-strength reinforced concrete columns under the conditions of different shear span-to-depth ratios requires further confirmation. For this purpose, six high-strength reinforced concrete columns with shear span-to-depth ratios of 2 and 4 were subjected to cyclic loading in this study. The experimental results indicated that relative nominal flexural strength, energy dissipation coefficient, factor of safety, and local factor of safety all exhibited a strong size effect by decreasing with increasing column size. Furthermore, the size effect became stronger as the shear span-to-depth ratio was increased, except for average energy dissipation coefficient. The observed changes in the factor of safety were in good agreement with the Type 2 size effect model proposed by Bažant. Thus, based on the local factor of safety and Bažant’s Type 2 model, the code equation for moment capacity of different shear span-to-depth ratios was modified to provide a consistent factor of safety regardless of column size.


2018 ◽  
Vol 27 (12) ◽  
pp. e1484 ◽  
Author(s):  
Wei Li ◽  
Linzhu Sun ◽  
Junliang Zhao ◽  
Pengfei Lu ◽  
Fang Yang

Sign in / Sign up

Export Citation Format

Share Document