Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments

2011 ◽  
Vol 55 (2) ◽  
pp. 247-252 ◽  
Author(s):  
Magda A. Akl ◽  
Mona A. Ahmed ◽  
Ahmed Ramadan
2005 ◽  
Vol 88 (5) ◽  
pp. 1555-1561 ◽  
Author(s):  
Irena Vovk ◽  
Breda Simonovska

Abstract A thin-layer chromatographic (TLC) method with densitometric quantitation using the absorption reflectance mode at 280 nm was developed and validated for the determination of chloramphenicol residues in controlling pharmaceutical equipment cleanliness. Simulated samples at residue levels 0.5, 1, and 1.2 mg/m2 were prepared by spreading the calculated amount of chloramphenicol solution on a 10 dm2 stainless steel surface. After evaporation of the solvent, the residue was removed by 2 methanol-wetted cotton swabs, which were then extracted with methanol. The extract was applied on a high-performance TLC (HPTLC) silica gel F254 plate together with standards ranging from 10 to 60 ng. Plates were developed in a horizontal developing chamber from both sides (36 applications per plate) by using n-hexane–ethyl acetate (35 + 65, v/v) as developing solvent. The mean recovery (n = 6) at 1 mg/m2 was 95.8%, and the coefficient of variation was 5.8%. The absolute detection limit was 3 ng, and the quantitation limit 10 ng. The method detection limit was 0.3 mg/m2 by swabbing 2.5 dm2 and 0.075 mg/m2 by swabbing 10 dm2. Chloramphenicol was stable on the plate 2 h before and 24 h after development. Additionally, it was stable during 7 days storage on the cotton swabs in the solvent at room temperature and in diluted standard solution stored in darkness at 4°C. The method can be applied to routine control of pharmaceutical equipment cleanliness by sampling from the stainless steel surface areas of 2.5 to 10 dm2, and an acceptable residue limit of 1 mg/m2.


2001 ◽  
Vol 84 (4) ◽  
pp. 1258-1264 ◽  
Author(s):  
Irena Vovk ◽  
Breda Simonovska

Abstract This paper presents the applicability of thin-layer chromatographic methods with a subsequent densitometric or video densitometric quantitation for determination of residues in controlling pharmaceutical equipment cleanliness. Analytical methods were developed for monitoring residues of pentoxifylline at 10 mg/m2 and mebendazol at 1 mg/m2 on stainless steel surfaces. Simulated samples were prepared by addition of a calculated amount of pharmaceutical (as a solution) on a 35 × 35 cm stainless steel surface. After evaporation of solvent, the residues were wiped with wetted cotton. The cotton was extracted with dichloromethan–methanol (1 + 1). Filtered extract was concentrated by vacuum evaporation and an aliquot applied to the plate, where standards were also applied. In the narrow concentration range near the acceptable residue limits, linear calibration curve could be obtained for both substances. The mean recovery (n = 4) obtained by densitometric quantitation was 93.4% for pentoxifylline and 85.6% for mebendazol, with coefficients of variation of 3.5 and 8.3%, respectively. Results of video densitometric quantitation did not differ significantly. However, data acquisition and evaluation is faster compared with densitometry and allows better archiving possibilities as required by the regulatory authorities. Both quantitation modes can be applied to routine control of pharmaceutical equipment cleanliness.


2018 ◽  
Vol 154 ◽  
pp. 01114 ◽  
Author(s):  
Aria Riswanda ◽  
Indro Pranoto ◽  
Deendarlianto ◽  
Indarto ◽  
Teguh Wibowo

Multiple droplets are drops of water that continuously dropped onto a surface. Spray cooling is an application of the use of droplet on a cooling system. Spray cooling is usually used in a cooling system of electronic devices, and material quenching. In this study, correlations between Weber number and surface temperature decrease rate during multiple droplets impingement are investigated and analyzed. Visualization process is used to help determine the evaporation time of droplets impingement by using high speed camera. Induction stove is used to maintain a stainless steel surface temperature at 120°C, 140°C, and 160°C. The Weber number was varied at 15, and 52.5 to simulate low and medium Weber number. The result of this study shows that increase in Weber number does not increase the temperature decrease rate noticeably. Whereas the Weber number decrease the time required for surface temperature to reach its lowest surface temperature. It was also found that for low and medium Weber number, Weber number affect the evaporation time of multiple droplets after impingement.