scholarly journals 938 NEEDLE STEERING SYSTEM USING DUTY-CYCLED ROTATION FOR PERCUTANEOUS KIDNEY ACCESS

2011 ◽  
Vol 185 (4S) ◽  
Author(s):  
Khaled Shahrour ◽  
Michael Ost ◽  
Nathan Wood ◽  
Stephen Jackman ◽  
Timothy Averch ◽  
...  
Author(s):  
Abdel-Salam Shaaban ◽  
Ahmed S. Ali ◽  
R. Mostafa ◽  
Fathi E. Abd El-Samie

2016 ◽  
Vol 01 (01) ◽  
pp. 1640007 ◽  
Author(s):  
Mohsen Khadem ◽  
Carlos Rossa ◽  
Ron S. Sloboda ◽  
Nawaid Usmani ◽  
Mahdi Tavakoli

In needle-based medical procedures, beveled tip flexible needles are steered inside soft tissue to reach the desired target locations. In this paper, we have developed an autonomous image-guided needle steering system that enhances targeting accuracy in needle insertion while minimizing tissue trauma. The system has three main components. First is a novel mechanics-based needle steering model that predicts needle deflection and accepts needle tip rotation as an input for needle steering. The second is a needle tip tracking system that determines needle deflection from the ultrasound images. The needle steering model employs the estimated needle deflection at the present time to predict needle tip trajectory in the future steps. The third component is a nonlinear model predictive controller (NMPC) that steers the needle inside the tissue by rotating the needle beveled tip. The MPC controller calculates control decisions based on iterative optimization of the predictions of the needle steering model. To validate the proposed ultrasound-guided needle steering system, needle insertion experiments in biological tissue phantoms are performed in two cases–with and without obstacle. The results demonstrate that our needle steering strategy guides the needle to the desired targets with the maximum error of 2.85[Formula: see text]mm.


Neurosurgery ◽  
2010 ◽  
Vol 67 (4) ◽  
pp. 1117-1123 ◽  
Author(s):  
Johnathan A Engh ◽  
Davneet S Minhas ◽  
Douglas Kondziolka ◽  
Cameron N Riviere

Abstract BACKGROUND: Intracerebral drug delivery using surgically placed microcatheters is a growing area of interest for potential treatment of a wide variety of neurological diseases, including tumors, neurodegenerative disorders, trauma, epilepsy, and stroke. Current catheter placement techniques are limited to straight trajectories. The development of an inexpensive system for flexible percutaneous intracranial navigation may be of significant clinical benefit. OBJECTIVE: Utilizing duty-cycled spinning of a flexible bevel-tipped needle, the authors devised and tested a means of achieving nonlinear trajectories for the navigation of catheters in the brain, which may be applicable to a wide variety of neurological diseases. METHODS: Exploiting the bending tendency of bevel-tipped needles due to their asymmetry, the authors devised and tested a means of generating curvilinear trajectories by spinning a needle with a variable duty cycle (ie, in on-off fashion). The technique can be performed using image guidance, and trajectories can be adjusted intraoperatively via joystick. Fifty-eight navigation trials were performed during cadaver testing to demonstrate the efficacy of the needle-steering system and to test its precision. RESULTS: The needle-steering system achieved a target acquisition error of 2 ± 1 mm, while demonstrating the ability to reach multiple targets from one burr hole using trajectories of varying curvature. CONCLUSION: The accuracy of the needle-steering system was demonstrated in a cadaveric model. Future studies will determine the safety of the device in vivo.


Sign in / Sign up

Export Citation Format

Share Document