Ultrasound-guided Tunneled Lower Extremity Peripherally Inserted Central Catheter Placement in Infants

2013 ◽  
Vol 24 (12) ◽  
pp. 1910-1913 ◽  
Author(s):  
Subramanian Subramanian ◽  
David C. Moe ◽  
Jack N. Vo
2018 ◽  
Vol 19 (6) ◽  
pp. 609-614 ◽  
Author(s):  
Soshi Nakamuta ◽  
Toshihiro Nishizawa ◽  
Shiori Matsuhashi ◽  
Arata Shimizu ◽  
Toshio Uraoka ◽  
...  

Background and aim: Malposition of peripherally inserted central catheters placed at the bedside is a well-recognized phenomenon. We report the success rate of the placement of peripherally inserted central catheters with ultrasound guidance for tip positioning and describe the knacks and pitfalls. Materials and methods: We retrospectively reviewed the medical case charts of 954 patients who received peripherally inserted central catheter procedure. Patient clinical data included success rate of puncture, detection rate of tip malposition with ultrasonography, adjustment rate after X-ray, and success rate of peripherally inserted central catheter placement. Results: The success rate of puncture was 100% (954/954). Detection rate of tip malposition with ultrasonography was 82.1% (78/95). The success rate of ultrasound-guided tip navigation was 98.2% (937/954). The success rate of ultrasound-guided tip location was 98.0% (935/954). Adjustment rate after X-ray was 1.79% (17/952). The final success rate of peripherally inserted central catheter placement was 99.8% (952/954). Conclusion: Ultrasound guidance for puncturing and tip positioning is a promising option for the placement of peripherally inserted central catheters. Ultrasound guidance could dispense with radiation exposure and the transfer of patients to the X-ray department.


Open Medicine ◽  
2017 ◽  
Vol 12 (1) ◽  
pp. 125-130 ◽  
Author(s):  
Lian-juan Zhou ◽  
Hong-zhen Xu ◽  
Mei-fang Xu ◽  
Yan Hu ◽  
Xiao-Fang Lou

AbstractObjectiveTo explore the clinical application of the intracavitary electrocardiogram (IC-ECG) guided Peripherally Inserted Central Catheter (PICC) tip placement among neonates.Backgroundthe ECGs of neonates are difficult to perform and their wave shapes are of doubtful accuracy due to various interfering factorsMethod115 neonates were admitted to perform PICC guided by IC-ECG. Logistic regression was performed to analyze all possible influencing factors of the accuracy from the tip placement. The puncture site of the PICC, gestational age, height, weight, basal P/R amplitude and positioning P/R amplitude might be related to the accuracy of IC-ECG location.ResultThe accuracy in the lower extremity was higher than that in the upper extremity. Multivariate logistic regression analysis showed that the weight (Odds Ratio (OR)=1.93, 95%Confidence Interval(CI):1.06-3.50) and positioning P/R amplitude (OR=32.33, 95%CI: 2.02-517.41) are statistically significant risks to the accuracy PICC tip placement.ConclusionsPossible methods to improve the accuracy might be Catheterizing through lower extremity, keeping the neonates calm, enhancing the electrocardiogram signal and strengthening technical training. Therefore it is practical to perfrom a tip placement by the dynamic change in the P waves from an electrocardiogram (ECG) guided PICC among neonates and as reliable as using X-rays.


Sign in / Sign up

Export Citation Format

Share Document