Wind loads on free-standing canopy roofs: Part 1 local wind pressures

2008 ◽  
Vol 96 (6-7) ◽  
pp. 1015-1028 ◽  
Author(s):  
Yasushi Uematsu ◽  
Theodore Stathopoulos ◽  
Eri Iizumi
1983 ◽  
Vol 109 (3) ◽  
pp. 816-820 ◽  
Author(s):  
David Surry ◽  
William Mallais

2006 ◽  
Vol 31 (4) ◽  
pp. 115-122
Author(s):  
Yasushi UEMATSU ◽  
Eri IIZUMI ◽  
Theodore STATHOPOULOS

2018 ◽  
Vol 232 ◽  
pp. 02028
Author(s):  
Bowei Liu ◽  
Yi Sun ◽  
Mei Wang

The wind loads could be increased by the complex hilly terrain. In order to consider this threat, computational simulations about wind pressures in buildings in hilly terrain and surrounding buildings were finished. In the CFD model, surrounding buildings within 500 meters and hilly terrain within 700 meters were established, and total 16 cases including different sensitive wind directions were simulated. The results showed that, because of the complex situation of surrounding hilly terrain and interfered buildings, wind loads in the building group under different direction show opposite characteristics. The speed-up effects by the hilly terrain increased the windward mean pressures when the flow comes from the north, while the interference effects by the surrounding buildings decreased them when the flow comes from the south.


2017 ◽  
Vol 17 (09) ◽  
pp. 1750104 ◽  
Author(s):  
Bo Chen ◽  
Pengpeng Zhong ◽  
Weihua Cheng ◽  
Xinzhong Chen ◽  
Qingshan Yang

The correlations among wind pressures on roof and walls are examined for the cylindrical roof buildings with different rise-span ratios based on wind tunnel data. Wind-induced dynamic response is also analyzed with a parametric study concerning span length, rise-span ratio, stiffness of supporting frames and connection type between roof and supporting frames, where the roof system is a single-layer cylindrical reticular shell. For both roof and supporting frames, the responses induced by vertical wind loads on the roof and by horizontal wind loads on the walls are investigated. The correlation coefficients of these response components are examined. The results showed that the fluctuating wind pressure on the roof is strongly correlated with the wind pressure on the side wall and the leeward wall, but weakly correlated with the wind pressure on the windward wall. The response of roof and supporting frames caused by the wind loads on the roof is much larger than that of wind loads on the walls. On the bases of a comprehensive parameter study and complete quadratic combination (CQC) rule, a practical simplified combination rule is suggested for estimating response of roof and supporting frames. It is given as sum of response component caused by wind load on roof and that of wind load on walls multiplied with a combination factor of [Formula: see text].


2008 ◽  
Vol 96 (6-7) ◽  
pp. 1029-1042 ◽  
Author(s):  
Yasushi Uematsu ◽  
Theodore Stathopoulos ◽  
Eri Iizumi
Keyword(s):  

2013 ◽  
Vol 639-640 ◽  
pp. 515-522
Author(s):  
Yong Gui Li ◽  
Q.S. Li

Wind tunnel test of 1:500 rigid model of tall building with atrium was carried out. Based on the experimental results, characteristics of wind pressures on atrium facades and wind loads on the structure were investigated in detail. The results show that the formation of flow separation on the building top plays a critical role in the generation of wind pressures on the atrium facades. Meanwhile, wind pressure coefficient distributions on the atrium facades are found to be relatively uniform. Moreover, the horizontal and vertical correlations of pressure coefficient exhibit high at most locations on atrium facades. With the increasing of the opening ratio, the mean wind pressure coefficients first decreased and then stabilized, and the fluctuating wind pressure coefficients first decreased and then increased. A design guideline for the wind-resistant design of atrium facades was proposed, and the results predicted by the proposed guideline were in good agreement with those from the wind tunnel tests, indicating that the proposed guideline can be used in engineering applications. When the opening ratio is no more than 5.33%, the effect of the facade pressures within the atrium on the wind loads on the structure can be ignored. For such cases, the wind-resistant design for a tall building with atrium can refer to that of a similar shape tall building without atrium.