scholarly journals Hemodynamic evaluation of different stent graft schemes in aortic arch covered stent implantation

Author(s):  
Jingxin Liu ◽  
Xinyong Cai ◽  
Yuliang Zhan ◽  
Hongmin Zhu ◽  
Haiyong Ao ◽  
...  
2019 ◽  
Vol 26 (5) ◽  
pp. 645-651 ◽  
Author(s):  
Ludovic Canaud ◽  
Baris Ata Ozdemir ◽  
Lucien Chassin-Trubert ◽  
Julien Sfeir ◽  
Pierre Alric ◽  
...  

Purpose: To evaluate outcomes of homemade fenestrated stent-grafts for complete endovascular aortic repair of aortic arch dissections. Materials and Methods: From July 2014 through September 2018, 35 patients (mean age 66±11 years; 25 men) underwent homemade fenestrated stent-graft repair of acute (n=16) or chronic (n=10) complicated type B aortic dissections (n=16) and dissecting aortic arch aneurysms subsequent to surgical treatment of acute type A dissections (n=9). Nineteen (54%) procedures were emergent. Results: Zone 2 single-fenestrated stent-grafts were used in 25 cases; the remaining 10 were double-fenestrated stent-grafts deployed in zone 0. Median time for stent-graft modification was 18 minutes (range 16–20). Technical success was achieved in all cases. An immediate distal type I endoleak was treated intraoperatively. Among the double-fenestrated stent-graft cases, the left subclavian artery fenestration could not be cannulated in 2 patients and revascularization was required. Partial coverage of the left common carotid artery necessitated placement of a covered stent in 3 cases. One (3%) patient had a stroke without permanent sequelae. Two type II endoleaks required additional covered stent placement at 5 and 7 days postoperatively, respectively. The 30-day mortality was 6% (2 patients with ruptured aortic arch aneurysm). During a mean follow-up of 17.6±13 months, there was no aortic rupture or retrograde dissection. One late type I endoleak was treated with additional proximal fenestrated stent-graft placement. One type II endoleak is currently under observation. One additional patient died (unrelated to the aorta); overall mortality was 9%. All supra-aortic trunks were patent. Conclusion: The use of homemade fenestrated stent-grafts for endovascular repair of aortic arch dissections is feasible and effective for total endovascular aortic arch repair. Durability concerns will need to be assessed in additional studies with long-term follow-up.


2019 ◽  
Vol 29 (09) ◽  
pp. 1137-1142
Author(s):  
Brian McCrossan ◽  
Lars Nolke ◽  
Damien Kenny ◽  
Paul Oslizlok ◽  
Gloria Crispino ◽  
...  

AbstractBackground:Recurrent aortic arch obstruction following the Norwood procedure is recognised as an important complication. Balloon arch angioplasty is associated with a high recoarctation rate.Methods:We sought to evaluate the prevalence and outcome of stent implantation for recoarctation in children following Norwood or Damus–Kaye–Stansel procedure over the past decade at a single national cardiology centre.Results:Of 114 children who underwent Norwood procedure or Damus–Kaye–Stansel procedure between January 2003 and June 2013, 80 patients survived. Of these 15 children underwent stent implantation for recoarctation. Six of these patients had previous balloon angioplasty. The median age at stent implantation was 4.4 months (range 2–82 months). The median peak aortic arch gradient at catheterisation decreased from 26mmHg (range 10–70mmHg) to 2mmHg (range 0–20mmHg). The median luminal diameter increased from 4.7 mm (range 3.2–7.9 mm) to 8.6 mm (range 6.2–10.9 mm). The median coarctation index increased by 0.49 (range = 0.24–0.64). A Valeo stent was employed in 11 children, a Palmaz Genesis stent in 2 patients, a MultiLink stent in 1 child, and a Jomed covered stent in 1 child. Two factors were associated with the need for stent placement: previous arch angioplasty (p valve < 0.001, χ-square 11.5) and borderline left ventricle (p = 0.04, χ-square = 4.1). Stent migration occurred in one child. There were two deaths related to poor right ventricular systolic function and severe tricuspid regurgitation. Six patients underwent redilation of the stent with no complications.Conclusions:The prevalence of recurrent aortic arch obstruction following Norwood/Damus–Kaye–Stansel procedure was 18%. Stent implantation is safe and reliably eliminates the aortic obstruction. Redilation can be successfully achieved to accommodate somatic growth or development of stent recoarctation.


2021 ◽  
pp. 152660282110025
Author(s):  
Nikolaos Konstantinou ◽  
Sven Peterss ◽  
Jan Stana ◽  
Barbara Rantner ◽  
Ramin Banafsche ◽  
...  

Purpose To present a novel technique to successfully cross a mechanical aortic valve prosthesis. Technique A 55-year-old female patient with genetically verified Marfan syndrome presented with a 5-cm anastomotic aneurysm of the proximal aortic arch after previous ascending aortic replacement due to a type A aortic dissection in 2007. The patient also underwent mechanical aortic valve replacement in 1991. A 3-stage hybrid repair was planned. The first 2 steps included debranching of the supra-aortic vessels. In the third procedure, a custom-made double branched endovascular stent-graft with a short 35-mm introducer tip was implanted. The mechanical valve was passed with the tip of the dilator on the lateral site of the leaflet, without destructing the valve and with only mild symptoms of aortic insufficiency, as one leaflet continued to work. This allowed the implantation of the stent-graft directly distally of the coronary arteries. Postoperative computed tomography angiography showed no endoleaks and patent coronary and supra-aortic vessels. Conclusion Passing a mechanical aortic valve prosthesis at the proper position is feasible and allows adequate endovascular treatment in complex arch anatomy. However, caution should be taken during positioning of the endovascular graft as the tip may potentially damage the valve prosthesis.


2021 ◽  
Vol 3 (4) ◽  
pp. 542-545
Author(s):  
Anastasios Kartas ◽  
Efstratios Karagiannidis ◽  
Georgios Sofidis ◽  
Nikolaos Stalikas ◽  
Anastasios Barmpas ◽  
...  

Author(s):  
Emilio Arbas-Redondo ◽  
Alfonso Jurado-Román ◽  
Santiago Jiménez-Valero ◽  
Guillermo Galeote-García ◽  
Ariana Gonzálvez-García ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document