Quantitative analysis of trace elements of silver disturbed by pulse pile up based on energy dispersive x-ray fluorescence (EDXRF) technique

Author(s):  
Jun Hao ◽  
Fusheng Li ◽  
Qingya Wang ◽  
Xiaoyu Jiang ◽  
Benyong Yang ◽  
...  
2004 ◽  
Vol 14 (03n04) ◽  
pp. 133-139 ◽  
Author(s):  
T. R. RAUTRAY ◽  
V. VIJAYAN ◽  
P. K. NAYAK ◽  
S. JENA

Coins are important archaeological objects that can provide useful information regarding preparation methodology and provenance. Their classification plays a fundamental role in dating historical events, in constructing trade routes and in establishing the welfare of population. Several Indian copper coins of different periods have been studied using Energy Dispersive X-ray Fluorescence (EDXRF) spectroscopic technique. The method is rapid, efficient, multi elemental and non-destructive in nature. Concentrations of the major and trace elements like Ca , Ti , V , Cr , Mn , Fe , Co , Ni , Cu , Zn , As and Pb have been estimated in these copper coins. In the present investigation, an attempt has been made to characterize some Indian copper coins of different periods using EDXRF technique.


1990 ◽  
Vol 18 (2) ◽  
pp. 140-144 ◽  
Author(s):  
Ambrogio S. Fassina ◽  
Irene Calliari ◽  
Adolfo Sangiorgio ◽  
Massimo Rossato ◽  
Mauro Ramigni ◽  
...  

1977 ◽  
Vol 10 ◽  
pp. 127-132 ◽  
Author(s):  
I.G. Stump ◽  
J. Carruthers ◽  
J.M. D'Auria ◽  
D.A. Applegarth ◽  
A.G.F. Davidson

Author(s):  
Y. Sato ◽  
T. Hashimoto ◽  
M. Ichihashi ◽  
Y. Ueki ◽  
K. Hirose ◽  
...  

Analytical TEMs have two variations in x-ray detector geometry, high and low angle take off. The high take off angle is advantageous for accuracy of quantitative analysis, because the x rays are less absorbed when they go through the sample. The low take off angle geometry enables better sensitivity because of larger detector solid angle.Hitachi HF-2000 cold field emission TEM has two versions; high angle take off and low angle take off. The former allows an energy dispersive x-ray detector above the objective lens. The latter allows the detector beside the objective lens. The x-ray take off angle is 68° for the high take off angle with the specimen held at right angles to the beam, and 22° for the low angle take off. The solid angle is 0.037 sr for the high angle take off, and 0.12 sr for the low angle take off, using a 30 mm2 detector.


2009 ◽  
Vol 19 (03n04) ◽  
pp. 167-173 ◽  
Author(s):  
B. B. TRIPATHY ◽  
T. R. RAUTRAY ◽  
SATYA R. DAS ◽  
MANAS R. DAS ◽  
V. VIJAYAN

The analysis of some of the Indian silver coins during British rule were analysed by Energy Dispersive X-Ray Fluorescence Technique. Eight elements namely Cr , Fe , Ni , Cu , Zn , As , Ag and Pb were estimated in this study which also seems to indicate the fragmentation as well as the impoverishment of the power for the regimes that had produced the studied coins. While Cu and Ag were present as major elements, other elements were found to be present in minor concentration.