Application of silicon drift detector in PIXE tomography system of Fudan University

Author(s):  
Shimei Wang ◽  
Tao Yu ◽  
Jing Li ◽  
Huanlu Xue ◽  
Xin Liu ◽  
...  
1997 ◽  
Vol 503 ◽  
Author(s):  
B. L. Evans ◽  
J. B. Martin ◽  
L. W. Burggraf

ABSTRACTThe viability of a Compton scattering tomography system for nondestructively inspecting thin, low Z samples for corrosion is examined. This technique differs from conventional x-ray backscatter NDI because it does not rely on narrow collimation of source and detectors to examine small volumes in the sample. Instead, photons of a single energy are backscattered from the sample and their scattered energy spectra are measured at multiple detector locations, and these spectra are then used to reconstruct an image of the object. This multiplexed Compton scatter tomography technique interrogates multiple volume elements simultaneously. Thin samples less than 1 cm thick and made of low Z materials are best imaged with gamma rays at or below 100 keV energy. At this energy, Compton line broadening becomes an important resolution limitation. An analytical model has been developed to simulate the signals collected in a demonstration system consisting of an array of planar high-purity germanium detectors. A technique for deconvolving the effects of Compton broadening and detector energy resolution from signals with additive noise is also presented. A filtered backprojection image reconstruction algorithm with similarities to that used in conventional transmission computed tomography is developed. A simulation of a 360–degree inspection gives distortion-free results. In a simulation of a single-sided inspection, a 5 mm × 5 mm corrosion flaw with 50% density is readily identified in 1-cm thick aluminum phantom when the signal to noise ratio in the data exceeds 28.


Author(s):  
Mark R. Woike ◽  
Jonathon D. Ponder ◽  
Judith F. Van Zante ◽  
Timothy J. Bencic ◽  
Laura King-Steen ◽  
...  

Author(s):  
Bruno Furtado de Moura ◽  
francisco sepulveda ◽  
Jorge Luis Jorge Acevedo ◽  
Wellington Betencurte da Silva ◽  
Rogerio Ramos ◽  
...  

2013 ◽  
Vol 64 (5) ◽  
Author(s):  
Muhammad Jaysuman Pusppanathan ◽  
Fazlul Rahman Yunus ◽  
Nor Muzakkir Nor Ayob ◽  
Ruzairi Abdul Rahim ◽  
Fatin Aliah Phang ◽  
...  

Electrical capacitance tomography (ECT) is one of process tomography technique which is developed rapidly in recent years. ECT is an imaging technique to obtain the internal permittivity distribution of a vessel or pipe by using capacitance electrodes sensor. This method has been integrated with ultrasonic tomography as multimodality system to perform multiphase flow measurement such as crude oil separation and oil process industry. In the present paper, a novel type of ECT sensor was developed using copper FR4 material. The electrode sensors can be flexibly bend or curve to fit the pipe surface for optimum measurement. Thus, every single sensor strip is designed to be functioned independently. Such system has lower sensing capability in the central of the sensing area which often contributes to poor imaging result. This problem can be overcome by combining the ECT with ultrasonic tomography to form a dual modality tomography system. By implementing the new ECT sensor, multiphase flow measurement image results can be achieved. The reconstructed image results are presented in this paper.


IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 61570-61580 ◽  
Author(s):  
Weichen Li ◽  
Junying Xia ◽  
Ge Zhang ◽  
Hang Ma ◽  
Benyuan Liu ◽  
...  

2015 ◽  
Author(s):  
Z. Yu ◽  
S. Leng ◽  
S. M. Jorgensen ◽  
Z. Li ◽  
R. Gutjahr ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 639
Author(s):  
Panagiotis Koulountzios ◽  
Tomasz Rymarczyk ◽  
Manuchehr Soleimani

Crystallisation is a crucial step in many industrial processes. Many sensors are being investigated for monitoring such processes to enhance the efficiency of them. Ultrasound techniques have been used for particle sizing characterization of liquid suspensions, in crystallisation process. An ultrasound tomography system with an array of ultrasound sensors can provide spatial information inside the process when compared to single-measurement systems. In this study, the batch crystallisation experiments have been conducted in a lab-scale reactor in calcium carbonate crystallisation. Real-time ultrasound tomographic imaging is done via a contactless ultrasound tomography sensor array. The effect of the injection rate and the stirring speed was considered as two control parameters in these crystallisation functions. Transmission mode ultrasound tomography comprises 32 piezoelectric transducers with central frequency of 40 kHz has been used. The process-based experimental investigation shows the capability of the proposed ultrasound tomography system for crystallisation process monitoring. Information on process dynamics, as well as process malfunction, can be obtained via the ultrasound tomography system.


Sign in / Sign up

Export Citation Format

Share Document