Experimental study of effect of ambient flow condition on the performance of a passive autocatalytic recombiner

2016 ◽  
Vol 301 ◽  
pp. 49-58 ◽  
Author(s):  
Zhe Liang ◽  
Lee Gardner ◽  
Tony Clouthier ◽  
Bryan Thomas
Author(s):  
Chiyuki Nakamata ◽  
Yoji Okita ◽  
Takashi Yamane ◽  
Yoshitaka Fukuyama ◽  
Toyoaki Yoshida

Cooling effectiveness of an impingement cooling with array of racetrack-shaped impingement holes is investigated. Two types of specimens are investigated. One is a plain target plate and the other is a plate roughened with bump type elements. Sensitivity of relative location of bump to impingement hole on the cooling effectiveness is also investigated. Experiments are conducted under three different mainflow Reynolds numbers ranging from 2.6×105 to 4.7×105, with four different cooling air Reynolds numbers for each main flow condition. The cooling air Reynolds numbers are in the range from 1.2×103 to 1.3×104.


2020 ◽  
Vol 34 (12) ◽  
pp. 15802-15811
Author(s):  
Xinxin Zhao ◽  
Xiangzhen Yan ◽  
Fei Cao ◽  
Wenguang Duan ◽  
Weiqi Fu ◽  
...  

2021 ◽  
Vol 224 ◽  
pp. 108708
Author(s):  
Xinjun Zou ◽  
Xiong Cao ◽  
Changlin Zhou ◽  
Mi Zhou ◽  
Xihong Zhang

2009 ◽  
Vol 2009.6 (0) ◽  
pp. 169-170
Author(s):  
Hiroki Ishida ◽  
Tomonori Tsukiya ◽  
Eisuke Tatsumi ◽  
Kenkichi Ohba

2013 ◽  
Vol 35 (1) ◽  
pp. 34-42 ◽  
Author(s):  
Bin Jiang ◽  
Ziyun Wang ◽  
Xiangzhao Fu ◽  
Yong Wang

Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


Sign in / Sign up

Export Citation Format

Share Document