Highly sensitive bending sensor based on multimode–multimode–coreoffset fiber structure

2015 ◽  
Vol 75 ◽  
pp. 52-56 ◽  
Author(s):  
Yanhui Qi ◽  
Lin Ma ◽  
Jiang Sun ◽  
Zexin Kang ◽  
Yunlong Bai ◽  
...  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Josu Amorebieta ◽  
Angel Ortega-Gomez ◽  
Gaizka Durana ◽  
Rubén Fernández ◽  
Enrique Antonio-Lopez ◽  
...  

AbstractWe propose and demonstrate a compact and simple vector bending sensor capable of distinguishing any direction and amplitude with high accuracy. The sensor consists of a short segment of asymmetric multicore fiber (MCF) fusion spliced to a standard single mode fiber. The reflection spectrum of such a structure shifts and shrinks in specific manners depending on the direction in which the MCF is bent. By monitoring simultaneously wavelength shift and light power variations, the amplitude and bend direction of the MCF can be unmistakably measured in any orientation, from 0° to 360°. The bending sensor proposed here is highly sensitive even for small bending angles (below 1°).


Micromachines ◽  
2019 ◽  
Vol 10 (8) ◽  
pp. 521 ◽  
Author(s):  
Yuan ◽  
Qian ◽  
Liu ◽  
Wang ◽  
Yu

Here we report on a miniaturized optical interferometer in one fiber based on two mismatched nodes. The all-fiber structure shows stable performance of temperature and humidity sensing. For temperature sensing in large ranges, from 40 to 100 °C, the sensor has a sensitivity of 0.24 dB/°C, and the adjusted R-squared value of fitting result reaches 0.99461 which shows a reliable sensing result. With carbon nanotubes coating the surface of the fiber, the temperature sensitivity is enhanced from 0.24561 to 1.65282 dB/°C in a small region, and the performance of humidity sensing becomes more linear and applicable. The adjusted R-squared value of the linear fitting line for humidity sensing shows a dramatic increase from 0.71731 to 0.92278 after carbon nanotube coating, and the humidity sensitivity presents 0.02571 nm/%RH.


Sensors ◽  
2019 ◽  
Vol 19 (1) ◽  
pp. 205 ◽  
Author(s):  
Lei Ding ◽  
Yu Li ◽  
Cai Zhou ◽  
Min Hu ◽  
Yuli Xiong ◽  
...  

A highly sensitive directional bending sensor based on a three-core fiber (TCF) Mach-Zehnder interferometer (MZI) is presented in this study. This MZI-based bending sensor was fabricated by fusion-splicing a section of TCF between two single-mode fibers (SMF) with core-offset. Due to the location of the core in the TCF, a bend applied to the TCF-based MZI led to an elongation or shortening of the core, which makes the sensor suitable for directional bending measurement. To analyze the bending characteristics, two types of TCF-based sensors, with the fusion-spliced core located at different positions between the SMFs, were investigated. A swept source was employed in the measurement technique. The experimental results showed that, for the two types of sensors in this setup, the bending sensitivities of the two sensors were 15.36 nm/m−1 and 3.11 nm/m−1 at the bending direction of 0°, and −20.48 nm/m−1 and −5.29 nm/m−1 at the bending direction of 180°. The temperature sensitivities of the two sensors were 0.043 nm/°C and 0.041 nm/°C, respectively. The proposed sensors are compact, versatile, inexpensive to fabricate, and are expected to have potential applications in biomedical sensing.


2016 ◽  
Vol 16 (18) ◽  
pp. 6899-6902 ◽  
Author(s):  
Jing Kong ◽  
Xiaowei Ouyang ◽  
Ai Zhou ◽  
Libo Yuan

2017 ◽  
Vol 25 (5) ◽  
pp. 5352 ◽  
Author(s):  
Huazhuo Dong ◽  
Liheng Chen ◽  
Junjie Zhou ◽  
Jianhui Yu ◽  
Heyuan Guan ◽  
...  

2021 ◽  
Author(s):  
Tao Geng ◽  
xiren jin ◽  
Zihang Xiang ◽  
Chu peng Lu ◽  
shuo zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document