Comprehensive study of fracture flow characteristic and feasibility of hybrid volume stimulation technique in tight fractured carbonate gas reservoir

2019 ◽  
Vol 174 ◽  
pp. 362-373 ◽  
Author(s):  
Jianchun Guo ◽  
Jichuan Ren ◽  
Shibin Wang ◽  
Chi Chen ◽  
Jie Lai ◽  
...  
2006 ◽  
Author(s):  
Zhimin Du ◽  
Xiao Guo ◽  
Yong Zhang ◽  
Feng Yang ◽  
Gaojin Shan ◽  
...  

2017 ◽  
Vol 35 (6) ◽  
pp. 2977-2989 ◽  
Author(s):  
Gian Paolo Giani ◽  
Andrea Gotta ◽  
Francesco Marzano ◽  
Vera Rocca

2013 ◽  
Vol 868 ◽  
pp. 682-685 ◽  
Author(s):  
Lin Jing Xu ◽  
Shi Cheng Zhang ◽  
Jian Ye Mou

In acid fracturing, excessive acid leakoff is thought to be the main reason that limits fracture propagation and live acid penetration distance, so its very important to do research about acid leak-off on naturally fractured carbonates. we developed a new model in this paper to simulate acid leakoff into a naturally fractured carbonates gas reservoir during acid fracturing. Our model incorporates the acid-rock reaction on the fractured surfaces. Given the information of the Puguang gas reservoir, the model predicts acid filtration and leakoff rate over time. In this study, we found that acid leak-off mechanism in naturally fractured carbonates is much different from that in reservoirs without natural fractures. The leakoff volume is several times of nonreactive acid. Since the acid widened natural fractures, leakoff velocity increase with time firstly , then decrease. While the leakoff velocity of the nonreactive fluid decrease sustained. We also analyze other sensitivity parameters of the acid leakoff. In this model, we explain the acid leakoff mechanism in naturally fractured carbonates, and provide a more accurate calculating of fluid loss.


2001 ◽  
Author(s):  
Alexander Weber ◽  
Franz Brauckmann ◽  
Lex Rijkels ◽  
Stephen J. Bourne

Author(s):  
F. A. Heckman ◽  
E. Redman ◽  
J.E. Connolly

In our initial publication on this subject1) we reported results demonstrating that contrast is the most important factor in producing the high image quality required for reliable image analysis. We also listed the factors which enhance contrast in order of the experimentally determined magnitude of their effect. The two most powerful factors affecting image contrast attainable with sheet film are beam intensity and KV. At that time we had only qualitative evidence for the ranking of enhancing factors. Later we carried out the densitometric measurements which led to the results outlined below.Meaningful evaluations of the cause-effect relationships among the considerable number of variables in preparing EM negatives depend on doing things in a systematic way, varying only one parameter at a time. Unless otherwise noted, we adhered to the following procedure evolved during our comprehensive study:Philips EM-300; 30μ objective aperature; magnification 7000- 12000X, exposure time 1 second, anti-contamination device operating.


Author(s):  
A. Singh ◽  
A. Dykeman ◽  
J. Jarrelf ◽  
D. C. Villeneuve

Hexachlorobenzene (HCB), a persistent and mobile organochlorine pesticide, occurs in environment. HCB has been shown to be present in human follicular fluid. An objective of the present report, which is part of a comprehensive study on reproductive toxicity of HCB, was to determine the cytologic effects of the compound on ovarian follicles in a primate model.Materials and Methods. Eight Cynomolgus monkeys were housed under controlled conditions at Animal facility of Health and Welfare, Ottawa. Animals were orally administered gelatin capsules containing HCB mixed with glucose in daily dosages of 0.0 or 10 mg/kg b.w. for 90 days; the former was the control group. On the menstrual period following completion of dosing, the monkeys underwent an induction cycle of superovulation. At necropsy, one-half of an ovary from each animal was diced into ca. 2- to 3-mm cubed specimens that were fixed by immersion in 2.5% glutaraldehyde in 0.1 M cacodylate buffer (pH 7.3). Subsequent procedures followed to obtain thin sections that were examined in a Hitachi H-7000 electron microscope have been described earlier.


Sign in / Sign up

Export Citation Format

Share Document