scholarly journals Full-Scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

2013 ◽  
Vol 52 ◽  
pp. 330-335 ◽  
Author(s):  
Jia-yun Sun ◽  
Zheng Fang ◽  
Juan-juan Chen
2011 ◽  
Vol 6 (6) ◽  
pp. 551-557 ◽  
Author(s):  
Shuji Moriyama ◽  

A smoke exhaust system must be installed basically in all high-rise buildings in Japan, in order to eliminate smoke and gas from combustible materials and ensure safe evacuation effectively. However, a new problem, i.e., the difficulty of opening and closing doors when a smoke exhaust fan is operating, has occurred since air-tightness has been improved in high-rise buildings. There are therefore many cases recently where a pressurized smoke control system is adopted. In this paper, the basic concept of this system is described and the pressurized smoke control system that is used in Harumi Triton Square, one of the largest high-rise buildings in Japan.


2022 ◽  
Author(s):  
João Carlos Viegas ◽  
Carlos Oliveira Costa ◽  
Bernardo P. B. Monteiro ◽  
Paulo Dias Pereira

2020 ◽  
Vol 177 ◽  
pp. 04003
Author(s):  
Sergey Prostov ◽  
Evgeniy Shabanov

This article presents the main results of the study of electrophysical processes occurring in the zone of electrical processing during the cleaning of soils from oil pollution. The main conclusions are formulated about the processes occurring in the electric processing zone by changing the relative electrical resistance of the soil, which was measured using microprobe sensors. A comparative analysis of the results of a laboratory experiment on the electrochemical cleaning of contaminated soil in a tank is carried out with the results of a full-scale experiment conducted on a plot of a soil mass in real conditions, but artificially contaminated with oil products (gasoline, used oil. Using single measurements of electrical resistivity by microprobe sensors, the spread of the pollutant in the soil was clarified , the relationship between the physical properties of the array and its electrical wire is established conductive properties. Confirmed high efficiency of this type of control in the study of complex processes occurring in the contaminated ground array.


2001 ◽  
Vol 251 (1-2) ◽  
pp. 29-48 ◽  
Author(s):  
S.T.S. Yuen ◽  
Q.J. Wang ◽  
J.R. Styles ◽  
T.A. McMahon

Author(s):  
Tania Ávila-Esquivel ◽  
José Pablo Aguiar-Moya ◽  
Edgar Camacho-Garita ◽  
Luis Loría-Salazar

Sign in / Sign up

Export Citation Format

Share Document