A novel electrical charging condensing heat exchanger for efficient particle emission reduction in small wood boilers

2020 ◽  
Vol 145 ◽  
pp. 521-529 ◽  
Author(s):  
Julija Grigonytė-Lopez Rodriguez ◽  
Heikki Suhonen ◽  
Ari Laitinen ◽  
Jarkko Tissari ◽  
Miika Kortelainen ◽  
...  
2008 ◽  
Vol 22 (1) ◽  
pp. 587-597 ◽  
Author(s):  
C. J. J. M. de Best ◽  
H. P. van Kemenade ◽  
T. Brunner ◽  
I. Obernberger

1992 ◽  
Author(s):  
Matthew E. Snyder ◽  
Michael P. Case ◽  
Sharon Jones ◽  
Richard Caron

1993 ◽  
Author(s):  
Robert W. Marsh ◽  
Mark E. Caron ◽  
Carol Metselaar ◽  
John Steele

2021 ◽  
Author(s):  
Yousuf Farooq

The aim of this project was to design a condensing heat exchanger to recover waste heat from an industrial clothes dryer. Industrial cloth dryers are inefficient in their use of energy because almost all of the energy input in the dryer is wasted in the atmosphere, and thus there is great potential for heat recovery. This energy can be used to preheat the incoming cold water, and the conventional heater can then heat the water to a final temperature. The warm moist air from the dryer carries both sensible and latent heat, and in order to design this heat recovery condensing heat exchanger, the heat transfer by both mass and sensible heat has to be accounted for. The basis of this heat and mass transfer problem was the energy balance at the interface, and separate models for the calculation of latent and sensible heat transfer were used. The mass transfer coefficients were obtained from an analogy with heat transfer, and the unknown interface temperature was solved for iteratively. The data for this design was collected from a 20 kW dryer, and the heat recovery from that dryer was observed to be about 17.3%. This heat recovery condensing heat exchanger efficiency can be enhanced by the addition of more coils to the heat exchanger. An improvement in the overall results can be expected if a practical study is done on the condensation heat exchanger for an industrial cloth dryer.


2020 ◽  
Vol 174 ◽  
pp. 115290 ◽  
Author(s):  
Kai Li ◽  
Enlu Wang ◽  
Qi Wang ◽  
Naveed Husnain ◽  
Deli Li

2014 ◽  
Vol 35 (4) ◽  
pp. 447-461 ◽  
Author(s):  
Paweł Rączka ◽  
Kazimierz Wójs

Abstract The paper presents the algorithms for a flue gas/water waste-heat exchanger with and without condensation of water vapour contained in flue gas with experimental validation of theoretical results. The algorithms were used for calculations of the area of a heat exchanger using waste heat from a pulverised brown coal fired steam boiler operating in a power unit with a capacity of 900 MWe. In calculation of the condensing part, the calculation results obtained with two algorithms were compared (Colburn-Hobler and VDI algorithms). The VDI algorithm allowed to take into account the condensation of water vapour for flue gas temperatures above the temperature of the water dew point. Thanks to this, it was possible to calculate more accurately the required heat transfer area, which resulted in its reduction by 19 %. In addition, the influence of the mass transfer on the heat transfer area was taken into account, which contributed to a further reduction in the calculated size of the heat exchanger - in total by 28% as compared with the Colburn-Hobler algorithm. The presented VDI algorithm was used to design a 312 kW pilot-scale condensing heat exchanger installed in PGE Belchatow power plant. Obtained experimental results are in a good agreement with calculated values.


2005 ◽  
Author(s):  
Klaus Bockstahler ◽  
Helmut Westermann ◽  
Johannes Witt

Sign in / Sign up

Export Citation Format

Share Document