Advanced Stainless Steel Condensing Heat Exchanger

Author(s):  
Klaus Bockstahler ◽  
Helmut Westermann ◽  
Johannes Witt
1992 ◽  
Author(s):  
Matthew E. Snyder ◽  
Michael P. Case ◽  
Sharon Jones ◽  
Richard Caron

1993 ◽  
Author(s):  
Robert W. Marsh ◽  
Mark E. Caron ◽  
Carol Metselaar ◽  
John Steele

2022 ◽  
Vol 7 (1) ◽  
pp. 77-83
Author(s):  
Andrea Szabó Nagy ◽  
Kálmán Varga ◽  
Bernadett Baja ◽  
Zoltán Németh ◽  
Desző Oravetz ◽  
...  

Our previous studies have revealed that a ”hybrid” structure of the amorphous and crystalline phases is formed in the outermost surface region of the austenitic stainless steel tubes of steam generators (SGs) as an undesired consequence of the industrial application of the AP-CITROX (AP: alkaline permanganate; CITROX: citric and oxalic acid) decontamination technology. The formation of this mobile oxide-layer increased the amount of the corrosion products in the primary circuit significantly, resulting in magnetite deposition on fuel assemblies. Owing to the fact that there is no investigation method available for the in-situ monitoring of the inner surfaces of heat exchanger tubes, a research project based on sampling as well as on ex-situ electrochemical and surface analytical measurements was elaborated. Within the frame of this project, comprehensive investigation of the general corrosion state and metallographic features of 36 stainless steel specimens, cut out from various locations of the 21 steam generators of the Paks NPP in the time period of 2000-2007 has been performed. The present work gives a brief overview on the general corrosion state of the heat exchanger tubes of SGs, concerning the long-term effects of the AP-CITROX procedure on the chemical composition and structure of the protective oxide-layer.


2021 ◽  
Author(s):  
Yousuf Farooq

The aim of this project was to design a condensing heat exchanger to recover waste heat from an industrial clothes dryer. Industrial cloth dryers are inefficient in their use of energy because almost all of the energy input in the dryer is wasted in the atmosphere, and thus there is great potential for heat recovery. This energy can be used to preheat the incoming cold water, and the conventional heater can then heat the water to a final temperature. The warm moist air from the dryer carries both sensible and latent heat, and in order to design this heat recovery condensing heat exchanger, the heat transfer by both mass and sensible heat has to be accounted for. The basis of this heat and mass transfer problem was the energy balance at the interface, and separate models for the calculation of latent and sensible heat transfer were used. The mass transfer coefficients were obtained from an analogy with heat transfer, and the unknown interface temperature was solved for iteratively. The data for this design was collected from a 20 kW dryer, and the heat recovery from that dryer was observed to be about 17.3%. This heat recovery condensing heat exchanger efficiency can be enhanced by the addition of more coils to the heat exchanger. An improvement in the overall results can be expected if a practical study is done on the condensation heat exchanger for an industrial cloth dryer.


2006 ◽  
Vol 326-328 ◽  
pp. 265-268
Author(s):  
Taek Joon Son ◽  
Young Shin Lee

The strength of micro heat exchanger under pressure is studied in this paper. Micro heat exchanger is made with brazing technology. It is constructed of stainless steel thin plates with micro channels and in/out port for fluid flow. Micro channels in thin plates are formed by etching and all parts including thin plates are joined by brazing. The study on the strength under pressure is performed by structural analysis. For structural analysis, one layer of micro heat exchanger body is considered. It is composed of thin plate with micro channel and brazing filler which is used to join thin plates. This paper shows the tendency of stress behavior and gives design guideline of micro heat exchanger.


Sign in / Sign up

Export Citation Format

Share Document