Natural gas pipeline leak detector based on NIR diode laser absorption spectroscopy

Author(s):  
Xiaoming Gao ◽  
Hong Fan ◽  
Teng Huang ◽  
Xia Wang ◽  
Jian Bao ◽  
...  
2016 ◽  
Vol 71 (5) ◽  
pp. 888-900 ◽  
Author(s):  
Javis Anyangwe Nwaboh ◽  
Sonja Pratzler ◽  
Olav Werhahn ◽  
Volker Ebert

We report a new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor for absolute measurements of H2O in methane, ethane, propane, and low CO2 natural gas. The sensor is operated with a 2.7 µm DFB laser, equipped with a high pressure single pass gas cell, and used to measure H2O amount of substance fractions in the range of 0.31–25 000 µmol/mol. Operating total gas pressures are up to 5000 hPa. The sensor has been characterized, addressing the traceability of the spectrometric results to the SI and the evaluation of the combined uncertainty, following the guide to the expression of uncertainty in measurement (GUM). The relative reproducibility of H2O amount of substance fraction measurements at 87 µmol/mol is 0.26% (0.23 µmol/mol). The maximum precision of the sensor was determined using a H2O in methane mixture, and found to be 40 nmol/mol for a time resolution of 100 s. This corresponds to a normalized detection limit of 330 nmol mol−1·m Hz−1/2. The relative combined uncertainty of H2O amount fraction measurements delivered by the sensor is 1.2%.


2020 ◽  
Vol 56 (12) ◽  
pp. 1284-1289
Author(s):  
Ya. Ya. Ponurovskii ◽  
D. B. Stavrovskii ◽  
Yu. P. Shapovalov ◽  
M. V. Spiridonov ◽  
A. S. Kuz’michev ◽  
...  

1994 ◽  
Vol 33 (Part 1, No. 7B) ◽  
pp. 4298-4302 ◽  
Author(s):  
Koji Maruyama ◽  
Katsunori Ohkouchi ◽  
Yasunori Ohtsu ◽  
Toshio Goto

2021 ◽  
Vol 16 (2) ◽  
pp. 222-229
Author(s):  
Lin Feng ◽  
Jian Wang ◽  
Chao Ding

Tunable diode laser absorption spectroscopy (TDLAS) technology is adopted herein to detect fire gas produced in the early stage of the fire. Based on this technology, a fire warning detection system with multiple lasers and detectors is proposed. Multiple drivers input laser’s temperature and injected current data, making its output wavelength consistent with the measured gas’ absorption peak wavelengths in absorption spectroscopy. Multiple light beams are coupled to the same optical fiber. After the light beams pass through the long optical path absorption cell filled with fire gas, the beams are separated by a converter. The signals are demodulated by different detectors and further analyzed for fire warnings. After the fire warning system’s design, the system’s various hardware modules are designed, including the light source module, TDLAS controller, gas chamber module, photoelectric detector, and data collection. When the temperature remains unchanged, the output wavelength is linearly related to the injected current. When the injected current remains unchanged, the output wavelength is linearly related to the operating temperature. With a semiconductor laser’s injected current of 40 mA, the initial temperature of 38.6 °C, and the output wavelength of 1578.16 nm, the output wavelength increases continuously as the temperature increases. The harmonic signal amplitude after gas absorption is positively correlated with the measured gas concentration, indicating that the second harmonic signals can estimate the fire gas concentration.