Transient and continuous effects of indoor human movement on nanoparticle concentrations in a sitting person's breathing zone

2022 ◽  
Vol 805 ◽  
pp. 149970
Author(s):  
Jialin Wu ◽  
Wenguo Weng ◽  
Liangchang Shen ◽  
Ming Fu
2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


2019 ◽  
Author(s):  
Gede H Cahyana

Indoor air pollution in closed room is one of the air pollution that gives serious threats to human health. One of them come from vehicle gas emissions in closed parking area. This research identifies and analyses CO concentration measured in Mall X parking man’s breathing zone with closed parking area and in Mall Y semi-opened parking area. CO measurement carried out by passive sampling method using Personal Dosimeter Tubes. Measurement result of CO gas concentration to parking man’s breathing zone in Mall X was 25 – 81,25 ppm with average value in 50 ± 26,15 ppm. Meanwhile CO gas concentration in Mall Y gave result 3,13 – 12,5 ppm with average value in 7,88 ± 4,36 ppm. Correlation value between CO concentration and its intake in Mall X area was 0,9983, meanwhile correlation value between CO concentration and its intake in Mall Y area was 0,9903. It was concluded that CO gas concentration measured in parking man’s breathing zone influenced the differences of CO intake value in significance value.


Sign in / Sign up

Export Citation Format

Share Document