ANALISIS PENGUKURAN KONSENTRASI KARBONMONOKSIDA (CO) PADA BREATHING ZONE PETUGAS PARKIR BASEMENT MALL KOTA BANDUNG
Indoor air pollution in closed room is one of the air pollution that gives serious threats to human health. One of them come from vehicle gas emissions in closed parking area. This research identifies and analyses CO concentration measured in Mall X parking man’s breathing zone with closed parking area and in Mall Y semi-opened parking area. CO measurement carried out by passive sampling method using Personal Dosimeter Tubes. Measurement result of CO gas concentration to parking man’s breathing zone in Mall X was 25 – 81,25 ppm with average value in 50 ± 26,15 ppm. Meanwhile CO gas concentration in Mall Y gave result 3,13 – 12,5 ppm with average value in 7,88 ± 4,36 ppm. Correlation value between CO concentration and its intake in Mall X area was 0,9983, meanwhile correlation value between CO concentration and its intake in Mall Y area was 0,9903. It was concluded that CO gas concentration measured in parking man’s breathing zone influenced the differences of CO intake value in significance value.