Reliability of pressure pain threshold testing in healthy pain free young adults

2015 ◽  
Vol 9 (1) ◽  
pp. 38-41 ◽  
Author(s):  
Robert Waller ◽  
Leon Straker ◽  
Peter O’Sullivan ◽  
Michele Sterling ◽  
Anne Smith

AbstractBackground and aimsInvestigation of the multidimensional correlates of pressure pain threshold (PPT) requires the study of large cohorts, and thus the use of multiple raters, for sufficient statistical power. Although PPT testing has previously been shown to be reliable, the reliability of multiple raters and investigation for systematic bias between raters has not been reported.The aim of this study was to evaluate the intrarater and interrater reliability of PPT measurement by handheld algometer at the wrist, leg, cervical spine and lumbar spine. Additionally the study aimed to calculate sample sizes required for parallel and cross-over studies for various effect sizes accounting for measurement error.MethodsFive research assistants (RAs) each tested 20 pain free subjects at the wrist, leg, cervical and lumbar spine. Intraclass correlation coefficient (ICC), standard error of measurement (SEM) and systematic bias were calculated.ResultsBoth intrarater reliability (ICC = 0.81–0.99) and interrater reliability (ICC = 0.92–0.95) were excellent and intrarater SEM ranged from 79 to 100 kPa. There was systematic bias detected at three sites with no single rater tending to consistently rate higher or lower than others across all sites.ConclusionThe excellent ICCs observed in this study support the utility of using multiple RAs in large cohort studies using standardised protocols, with the caveat that an absence of any confounding of study estimates by rater is checked, due to systematic rater bias identified in this study.ImplicationsThorough training of raters using PPT results in excellent interrater reliability. Clinical trials using PPT as an outcome measure should utilise a priori sample size calculations.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Bernard Liew ◽  
Ho Yin Lee ◽  
David Rügamer ◽  
Alessandro Marco De Nunzio ◽  
Nicola R. Heneghan ◽  
...  

AbstractThe inter-session Intraclass Correlation Coefficient (ICC) is a commonly investigated and clinically important metric of reliability for pressure pain threshold (PPT) measurement. However, current investigations do not account for inter-repetition variability when calculating inter-session ICC, even though a PPT measurement taken at different sessions must also imply different repetitions. The primary aim was to evaluate and report a novel metric of reliability in PPT measurement: the inter-session-repetition ICC. One rater recorded ten repetitions of PPT measurement over the lumbar region bilaterally at two sessions in twenty healthy adults using a pressure algometer. Variance components were computed using linear mixed-models and used to construct ICCs; most notably inter-session ICC and inter-session-repetition ICC. At 70.1% of the total variance, the source of greatest variability was between subjects ($${\sigma }_{subj}^{2}$$ σ subj 2 = 222.28 N2), whereas the source of least variability (1.5% total variance) was between sessions ($${\sigma }_{sess}^{2}$$ σ sess 2 = 4.83 N2). Derived inter-session and inter-session-repetition ICCs were 0.88 (95%CI: 0.77 to 0.94) and 0.73 (95%CI: 0.53 to 0.84) respectively. Inter-session-repetition ICC provides a more conservative estimate of reliability than inter-session ICC, with the magnitude of difference being clinically meaningful. Quantifying individual sources of variability enables ICC construction to be reflective of individual testing protocols.


2014 ◽  
Vol 94 (6) ◽  
pp. 827-837 ◽  
Author(s):  
David M. Walton ◽  
Lenerdene Levesque ◽  
Martin Payne ◽  
Julie Schick

Background Quantitative sensory testing, including pressure pain threshold (PPT), is seeing increased use in clinical practice. In order to facilitate clinical utility, knowledge of the properties of the tool and interpretation of results are required. Objectives This observational study used a clinical sample of people with mechanical neck pain to determine: (1) the influence of number of testing repetitions on measurement properties, (2) reliability and minimum clinically important difference, and (3) associations between PPT and key psychological constructs. Design This study was observational with both cross-sectional and prospective elements. Methods Experienced clinicians measured PPT in patients with mechanical neck pain following a standardized protocol. Subcohorts also provided repeated measures and completed scales of key psychological constructs. Results The total sample was 206 participants, but not all participants provided data for all analyses. Interrater and 1-week test-retest reliability were excellent (intraclass correlation coefficients [2,1]=.75–.95). Potentially important differences in reliability and PPT scores were found when using only 1 or 2 repeated measures compared with all 3. The PPT over a distal location (tibialis anterior muscle) was not adequately responsive in this sample, but the local site (upper trapezius muscle) was responsive and may be useful as part of a protocol to evaluate clinical change. Sensitivity values (range=0.08–0.50) and specificity values (range=0.82–0.97) for a range of change scores are presented. Depression, catastrophizing, and kinesiophobia were able to explain small but statistically significant variance in local PPT (3.9%–5.9%), but only catastrophizing and kinesiophobia explained significant variance in the distal PPT (3.6% and 2.9%, respectively). Limitations Limitations of the study include multiple raters, unknown recruitment rates, and unknown measurement properties at sites other than those tested here. Conclusions The results suggest that PPT is adequately reliable and that 3 measurements should be taken to maximize measurement properties. The variance explained by the psychological variables was small but significant for 3 constructs related to catastrophizing, depression, and fear of movement. Clinical implications for application and interpretation of PPT are discussed.


2012 ◽  
Vol 17 (2) ◽  
pp. 98-102 ◽  
Author(s):  
Gwyn N Lewis ◽  
Heales Luke ◽  
David A Rice ◽  
Keith Rome ◽  
Peter J McNair

BACKGROUND: Conditioned pain modulation paradigms are often used to assess the diffuse noxious inhibitory control (DNIC) system. DNICs provide one of the main supraspinal pain inhibitory pathways and are impaired in several chronic pain populations. Only one previous study has examined the psychometric properties of the conditioned pain modulation technique and this study did not evaluate intersession reliability.OBJECTIVES: To evaluate and compare the intra- and intersession reliability of two conditioned pain modulation paradigms using different conditioning stimuli, and to determine the time course of conditioned pain inhibition following stimulus removal.METHODS: An electronic pressure transducer was used to determine the pressure-pain threshold at the knee during painful conditioning of the opposite hand using the ischemic arm test and the cold pressor test. Assessments were completed twice on one day and repeated once approximately three days later.RESULTS: The two conditioning stimuli resulted in a similar increase in the pressure-pain threshold at the knee, reflecting presumed activation of the DNIC system. Intrasession intraclass correlation coefficients for the cold pressor (0.85) and ischemic arm tests (0.75) were excellent. The intersession intraclass correlation coefficient for the cold pressor test was good (0.66) but was poor for the ischemic arm test (−0.4). Inhibition of the pressure-pain threshold remained significant at 10 min following conditioning, but returned to baseline by 15 min.CONCLUSIONS: Within-session reliability of DNIC assessment using conditioned pain modulation paradigms was excellent, but the applicability of assessing pain modulation over multiple sessions was influenced by the conditioning stimulus. The cold pressor test was the superior technique.


2018 ◽  
Vol 18 (2) ◽  
pp. 229-236 ◽  
Author(s):  
Neeraja Srimurugan Pratheep ◽  
Pascal Madeleine ◽  
Lars Arendt-Nielsen

Abstract Background and aims: Pressure pain threshold (PPT) and PPT maps are commonly used to quantify and visualize mechanical pain sensitivity. Although PPT’s have frequently been reported from patients with knee osteoarthritis (KOA), the absolute and relative reliability of PPT assessments remain to be determined. Thus, the purpose of this study was to evaluate the test-retest relative and absolute reliability of PPT in KOA. For that purpose, intra- and interclass correlation coefficient (ICC) as well as the standard error of measurement (SEM) and the minimal detectable change (MDC) values within eight anatomical locations covering the most painful knee of KOA patients was measured. Methods: Twenty KOA patients participated in two sessions with a period of 2 weeks±3 days apart. PPT’s were assessed over eight anatomical locations covering the knee and two remote locations over tibialis anterior and brachioradialis. The patients rated their maximum pain intensity during the past 24 h and prior to the recordings on a visual analog scale (VAS), and completed The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and PainDetect surveys. The ICC, SEM and MDC between the sessions were assessed. The ICC for the individual variability was expressed with coefficient of variance (CV). Bland-Altman plots were used to assess potential bias in the dataset. Results: The ICC ranged from 0.85 to 0.96 for all the anatomical locations which is considered “almost perfect”. CV was lowest in session 1 and ranged from 44.2 to 57.6%. SEM for comparison ranged between 34 and 71 kPa and MDC ranged between 93 and 197 kPa with a mean PPT ranged from 273.5 to 367.7 kPa in session 1 and 268.1–331.3 kPa in session 2. The analysis of Bland-Altman plot showed no systematic bias. PPT maps showed that the patients had lower thresholds in session 2, but no significant difference was observed for the comparison between the sessions for PPT or VAS. No correlations were seen between PainDetect and PPT and PainDetect and WOMAC. Conclusions: Almost perfect relative and absolute reliabilities were found for the assessment of PPT’s for KOA patients. Implications: The present investigation implicates that PPT’s is reliable for assessing pain sensitivity and sensitization in KOA patients.


2017 ◽  
Author(s):  
Marta Kialka ◽  
Tomasz Milewicz ◽  
Krystyna Sztefko ◽  
Iwona Rogatko ◽  
Renata Majewska

Sign in / Sign up

Export Citation Format

Share Document