Rapid C-reactive protein determination in whole blood with a White Light Reflectance Spectroscopy label-free immunosensor for Point-of-Care applications

2018 ◽  
Vol 260 ◽  
pp. 282-288 ◽  
Author(s):  
Georgios Koukouvinos ◽  
Dimitrios Goustouridis ◽  
Konstantinos Misiakos ◽  
Sotirios Kakabakos ◽  
Ioannis Raptis ◽  
...  
Biosensors ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 268
Author(s):  
Dimitra Tsounidi ◽  
Georgios Koukouvinos ◽  
Vasilios Christianidis ◽  
Evangelia Legaki ◽  
Vasiliki Giogli ◽  
...  

The development of methods and miniaturized systems for fast and reliable quantitative determinations at the Point-of-Care is a top challenge and priority in diagnostics. In this work, a compact bench-top system, based on White Light Reflectance Spectroscopy, is introduced and evaluated in an application with high clinical interest, namely the determination of C-Reactive protein (CRP) in human blood samples. The system encompassed all the necessary electronic and optical components for the performance of the assay, while the dedicated software provided the sequence and duration of assay steps, the reagents flow rate, the real-time monitoring of sensor response, and data processing to deliver in short time and accurately the CPR concentration in the sample. The CRP assay included two steps, the first comprising the binding of sample CRP onto the chip immobilized capture antibody and the second the reaction of the surface immunosorbed CRP molecules with the detection antibody. The assay duration was 12 min and the dynamic range was from 0.05 to 200 μg/mL, covering both normal values and acute inflammation incidents. There was an excellent agreement between CRP values determined in human plasma samples using the developed device with those received for the same samples by a standard diagnostic laboratory method.


Biosensors ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 4
Author(s):  
Donggee Rho ◽  
Seunghyun Kim

An optical cavity-based biosensor (OCB) has been developed for point-of-care (POC) applications. This label-free biosensor employs low-cost components and simple fabrication processes to lower the overall cost while achieving high sensitivity using a differential detection method. To experimentally demonstrate its limit of detection (LOD), we conducted biosensing experiments with streptavidin and C-reactive protein (CRP). The optical cavity structure was optimized further for better sensitivity and easier fluid control. We utilized the polymer swelling property to fine-tune the optical cavity width, which significantly improved the success rate to produce measurable samples. Four different concentrations of streptavidin were tested in triplicate, and the LOD of the OCB was determined to be 1.35 nM. The OCB also successfully detected three different concentrations of human CRP using biotinylated CRP antibody. The LOD for CRP detection was 377 pM. All measurements were done using a small sample volume of 15 µL within 30 min. By reducing the sensing area, improving the functionalization and passivation processes, and increasing the sample volume, the LOD of the OCB are estimated to be reduced further to the femto-molar range. Overall, the demonstrated capability of the OCB in the present work shows great potential to be used as a promising POC biosensor.


2003 ◽  
Vol 332 (1-2) ◽  
pp. 51-59 ◽  
Author(s):  
Jae Soon Ahn ◽  
Sunga Choi ◽  
Sang Ho Jang ◽  
Hyuk Jae Chang ◽  
Jae Hoon Kim ◽  
...  

2014 ◽  
Author(s):  
Panagiota Petrou ◽  
Georgios Koukouvinos ◽  
Dimitrios Drygiannakis ◽  
Dimitris Goustouridis ◽  
Ioannis Raptis ◽  
...  

2002 ◽  
Vol 48 (2) ◽  
pp. 269-277 ◽  
Author(s):  
Piia Tarkkinen ◽  
Tom Palenius ◽  
Timo Lövgren

Abstract Background: Recently, measurement of very low concentrations of C-reactive protein (CRP) has gained popularity as a potential new means for predicting the risk of future cardiac complications. In this study, we demonstrate the feasibility of a kinetic, one-step microparticle assay for quantitative determination of extremely low and high CRP concentrations in the limited timeframe typical for point-of-care testing. Methods: A noncompetitive, kinetic CRP immunoassay was developed that uses individual, porous microparticles as the solid phase. The microparticles were covalently coated with a monoclonal capture antibody, and the monoclonal detection antibody was labeled with europium. The one-step binding reaction was stopped by washing after 2 min of incubation, and the fluorescence signal of individual particles was measured. Results: The analytical detection limit (mean of zero calibrator + 3 SD) was 0.00016 mg/L CRP. Clinical samples were diluted 400-fold before assay to cover the CRP concentration range of 0.064–1200 mg/L. The assay correlated well with the Dade Behring N High Sensitivity CRP assay (for 0–10 mg/L, r = 0.969, Sy|x = 0.68, n = 54; for 0–350 mg/L, r = 0.969, Sy|x = 11.7, n = 100). The within- and between-run CVs based on calculated concentrations were, respectively, 9–16% and 14% at 0.11 mg/L, 4.5–12% and 8.2% at 4.2 mg/L, and 3.5–6.3% and 4.4% at 105 mg/L, with a CV <15% at 0.2 mg/L and above. Conclusions: Use of the kinetic microparticle approach combined with time-resolved fluorometry allows ultrasensitive quantification of CRP in whole blood in 2 min with a linear assay range spanning more than four orders of magnitude.


Biosensors ◽  
2017 ◽  
Vol 7 (4) ◽  
pp. 46 ◽  
Author(s):  
Georgios Koukouvinos ◽  
Panagiota Petrou ◽  
Dimitrios Goustouridis ◽  
Konstantinos Misiakos ◽  
Sotirios Kakabakos ◽  
...  

2006 ◽  
Vol 1 (2) ◽  
pp. 94 ◽  
Author(s):  
M. Zavali ◽  
P.S. Petrou ◽  
S.E. Kakabakos ◽  
M. Kitsara ◽  
I. Raptis ◽  
...  

2019 ◽  
Vol 282 ◽  
pp. 104-111 ◽  
Author(s):  
Dimitra Tsounidi ◽  
Georgios Koukouvinos ◽  
Panagiota Petrou ◽  
Konstantinos Misiakos ◽  
Grigorios Zisis ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document