Technical implementation and clinical findings/results of monitoring oxygen saturation in patients referred for long term EEG monitoring

1996 ◽  
Vol 99 (5) ◽  
pp. 432-439 ◽  
Author(s):  
J.R. Ives ◽  
N.R. Mainwaring ◽  
K.B. Krishnamurthy ◽  
A.S. Blum ◽  
F.W. Drislane ◽  
...  
Epilepsia ◽  
1996 ◽  
Vol 37 (7) ◽  
pp. 651-656 ◽  
Author(s):  
Gregory D. Cascino ◽  
Max R. Trenerry ◽  
Elson L. So ◽  
Frank W. Sharbrough ◽  
Cheolsu Shin ◽  
...  

2021 ◽  
Vol 141 (3) ◽  
pp. 527-533
Author(s):  
P. Moog ◽  
M. Dozan ◽  
J. Betzl ◽  
I. Sukhova ◽  
H. Kükrek ◽  
...  

Abstract Introduction Although the WALANT technique’s long-term safeness has been demonstrated in many studies, there are only few data investigating its short-term effects on tissue perfusion and oxygen levels. It was hypothesized that, temporarily, critical levels of tissue perfusion may occur. Methods Seventeen patients, who were scheduled for different procedures in WALANT technique, were injected with 5–7 ml of 1% Articain containing 1:200,000 epinephrine at the finger base. Capillary-venous oxygen saturation, hemoglobin volume in the capillaries, and relative blood flow in the fingertips were recorded once per second by white light spectrometry and laser Doppler flowmetry before, during and after injection for an average of 32 min. Results Clinically, no persistent tissue malperfusion was observed, and there were no postoperative complications. Capillary-venous oxygen saturation was reduced by ≥ 30% in seven patients. Critical levels of oxygen saturation were detected in four patients during 13 intervals, each lasting for 132.5 s on average. Oxygen saturation returned to noncritical values in all patients by the end of the observation period. Blood flow in the fingertips was reduced by more than 30% in nine patients, but no critical levels were observed, as with the hemoglobin. Three patients demonstrated a reactive increase in blood flow of more than 30% after injection. Conclusions Injection of tumescent local anesthesia containing epinephrine into finger base may temporarily cause a substantial reduction in blood flow and lead to critical levels of oxygen saturation in the fingertips. However, this was fully reversible within minutes and does not cause long-term complications.


2006 ◽  
Vol 130 (11) ◽  
pp. 1684-1686 ◽  
Author(s):  
Zeynep N. Salih ◽  
Afreen Akhter ◽  
Javeed Akhter

Abstract Context.—The presence of iron or hemosiderin in macrophages obtained in routine bronchoalveolar lavage is considered crucial in the diagnosis of the clinical syndrome of hemosiderosis. However, there do not appear to be any data on the sensitivity and specificity of the finding of hemosiderin-laden macrophages (HLMs) in bronchoalveolar lavage in children. Objective.—To review data from bronchoalveolar lavage studies done in children to correlate the presence of HLMs with pneumonia and hemosiderosis and to determine what proportion of HLMs has the optimal sensitivity and specificity for the diagnosis of hemosiderosis. Design.—One hundred ten bronchoalveolar lavage specimens obtained via flexible bronchoscopy were reviewed retrospectively. The data collected for demographics, indication for the bronchoscopy, diagnosis of pneumonia, anemia, and bronchoscopy and bronchoalveolar lavage findings were compared between patients diagnosed with hemosiderosis and those diagnosed with other diseases. Results.—Six patients were diagnosed with hemosiderosis by clinical findings, lung biopsy, or autopsy. There were no statistical differences in pneumonia (P > .99), anemia (P > .99), or coughing (P = .08) between patients with hemosiderosis and other patients. Hemoptysis was the only symptom that was significantly different between the 2 groups (P = .04). The mean HLM index for patients with hemosiderosis was 56% ± 16.17% and for other patients, 7.5% ± 10.74% (P < .001). A HLM index of 35% gave a sensitivity of 1% and a specificity of .96%. Conclusions.—These results confirm a strong association between HLM index and diagnosis of hemosiderosis in a pediatric population. Availability of this HLM index will result in accurate and timely diagnosis of pulmonary hemosiderosis, which may influence treatment and long-term prognosis.


2021 ◽  
Vol 121 (5) ◽  
pp. 62
Author(s):  
M.V. Sinkin ◽  
A.E. Talypov ◽  
A.A. Yakovlev ◽  
O.O. Kordonskaya ◽  
A.M. Teplyshova ◽  
...  

2021 ◽  
Vol 32 (8) ◽  
pp. 312-316
Author(s):  
Paul Silverston

The pandemic has led to an increase in the use of pulse oximetry to assess and manage patients with COVID-19 disease. Paul Silverston explains the principles of pulse oximetry and the factors that can affect the reliability and accuracy of readings Pulse oximetry is performed to detect and quantify the degree of hypoxia in patients with respiratory symptoms and illnesses, including patients with COVID-19 disease. Pulse oximeters are non-invasive, simple to use and inexpensive, but it is important to know how to interpret the readings in the context of the patient's symptoms and the other clinical findings. In COVID-19 disease, very small differences in the oxygen saturation reading result in significant differences in the way that the patient is managed, so it is important to be aware of the factors that can affect these readings. It is also important to appreciate that a low reading in a patient with suspected or confirmed COVID-19 disease may be the result of another disease process.


Seizure ◽  
2018 ◽  
Vol 63 ◽  
pp. 48-51 ◽  
Author(s):  
Xi Liu ◽  
Naoum P. Issa ◽  
Sandra Rose ◽  
Shasha Wu ◽  
Taixin Sun ◽  
...  

1978 ◽  
Vol 45 (2) ◽  
pp. 211-225 ◽  
Author(s):  
A Bricolo ◽  
S Turazzi ◽  
F Faccioli ◽  
F Odorizzi ◽  
G Sciarretta ◽  
...  

2015 ◽  
Vol 2 (1) ◽  
pp. 37-40
Author(s):  
Yacouba Njankouo Mapoure ◽  
◽  
Namme Henry Luma ◽  
Cyrille Nkouonlack ◽  
Ariane Vanessa Pokossy ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document