Monitoring of eutrophication and nutrient limitation in the Izmir Bay (Turkey) before and after Wastewater Treatment Plant

2004 ◽  
Vol 29 (8) ◽  
pp. 1057-1062 ◽  
Author(s):  
A Kontas ◽  
F Kucuksezgin ◽  
O Altay ◽  
E Uluturhan
2012 ◽  
Vol 11 (1) ◽  
pp. 113-123 ◽  
Author(s):  
Sunlu F. Sanem ◽  
Sunlu Ugur ◽  
Buyukisik Baha ◽  
Kukrer Serkan ◽  
Uncumusaoglu Arzu

2005 ◽  
Vol 51 (11) ◽  
pp. 159-166
Author(s):  
E. Ubay-Cokgor ◽  
C.W. Randall ◽  
D. Orhon

In this paper, the performance of the Tyson Foods wastewater treatment plant with an average flow rate of 6500 m3/d was evaluated before and after upgrading of the treatment system for nitrogen removal. This study was also covered with an additional recommendation of BIOWINTM BNR program simulation after the modification period to achieve an additional nutrient removal. The results clearly show that the upgrading was very successful for improved nitrogen removal, with a 57% decrease on the total nitrogen discharge. There also were slight reductions in the discharged loads of biological oxygen demand, total suspended solids, ammonium and total phosphorus with denitrification, even though the effluent flow was higher during operation of the nitrogen removal configuration.


2014 ◽  
Vol 878 ◽  
pp. 702-707 ◽  
Author(s):  
Chang Liu ◽  
Ping Zeng ◽  
Yong Hui Song ◽  
Jian Guang Cheng ◽  
Chao Wei Zhu ◽  
...  

Three kinds of surplus activated sludge were pretreated by alkali and combination of alkali and ultrasonic. The changes of PO43-P, TP, SCOD, TOC, TS, VS before and after pretreatment were investigated. The results showed that phosphorus and organic matter could be released into supernatant both by alkali and ultrasonic. The surplus activated sludge from municipal wastewater treatment plant was easier to be broken than that from pharmaceutical wastewater treatment plant. The activated sludge from Qinghe wastewater treatment plant could be selected for further phosphorus recovery since the largest quantity of phosphorus release and the lowest organic matter release ratio among the three kinds of surplus activated sludge.


Water ◽  
2019 ◽  
Vol 11 (11) ◽  
pp. 2367 ◽  
Author(s):  
Andrzej Kulig ◽  
Mirosław Szyłak-Szydłowski

Methodological aspects of odor studies in ex-post analyses for Polish wastewater management facilities were analyzed based on the example of a modernized and enlarged wastewater treatment plant (WWTP) in Mazovia, in the vicinity of the Warsaw agglomeration. It is a mechanical–biological treatment plant with increased efficiency of biogen removal, using activated sludge in the treatment process, with a maximum hydraulic capacity of 60,000 m3/day. Olfactometric research was carried out by means of a method based on identification and characterization of the odor plume emitted from the examined source. This paper presents the results of odor intensity assessment (in sensory examinations according to a 6-stage scale) and odor concentration measurement (using portable field olfactometers) after the completion of the project, and compares them with similar studies conducted before the commencement of the investment. A total of 10 measurement series were carried out before modernization, and 12 after modernization of the WWTP. Odor concentration and intensity were determined, and the current meteorological situation was assessed at the measurement and observation points (receptors) located within the premises (in total 462 points) and around the WWTP (342 points). In each series of measurements on the windward side of the treatment plant, the background of air pollution with odorous substances was marked. The research showed that air flowing into the area of the sewage treatment plant is clean in terms of odor. During the research, basic sources of odor nuisance were identified, and their impact before and after modernization was characterized. The results presented in radar diagrams show changes in the percentage distribution of frequency of occurrence of individual intensity values at receptor points within and outside the area of the treatment plant. After modernization, a significant decrease in the concentration of odor emitted from the sludge dewatering building and sludge containers was determined. The air-tightness of the sewage channel (covered with concrete slabs and sealed) resulted in a significant decrease in the concentration of odor emitted from this source. Waste (in particular, sewage sludge) collected in the emergency waste storage yard was identified as the main source of odor nuisance. The waste, even after modernization, was an emitter of odorous compounds spreading outside the area of the WWTP. Nevertheless, as a result of the investment, the desired effect of reduction of the degree of odor nuisance was achieved.


2016 ◽  
Vol 2 (5) ◽  
pp. 864-874 ◽  
Author(s):  
Laura E. Hubbard ◽  
Steffanie H. Keefe ◽  
Dana W. Kolpin ◽  
Larry B. Barber ◽  
Joseph W. Duris ◽  
...  

WWTP cessation is a rare environmental event with far-ranging hydrologic effects. Results have implications for shallow-groundwater recharge and WWTP-derived contamination kilometers downstream from the outfall.


Sign in / Sign up

Export Citation Format

Share Document