scholarly journals Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging

Author(s):  
R Botnar
2000 ◽  
Vol 10 (1) ◽  
pp. 18-26 ◽  
Author(s):  
René Botnar ◽  
Eike Nagel ◽  
Markus Beat Scheidegger ◽  
Erik Morre Pedersen ◽  
Otto Hess ◽  
...  

VASA ◽  
2005 ◽  
Vol 34 (3) ◽  
pp. 181-185 ◽  
Author(s):  
Westhoff-Bleck ◽  
Meyer ◽  
Lotz ◽  
Tutarel ◽  
Weiss ◽  
...  

Background: The presence of a bicuspid aortic valve (BAV) might be associated with a progressive dilatation of the aortic root and ascending aorta. However, involvement of the aortic arch and descending aorta has not yet been elucidated. Patients and methods: Magnetic resonance angiography (MRA) was used to assess the diameter of the ascending aorta, aortic arch, and descending aorta in 28 patients with bicuspid aortic valves (mean age 30 ± 9 years). Results: Patients with BAV, but without significant aortic stenosis or regurgitation (n = 10, mean age 27 ± 8 years, n.s. versus control) were compared with controls (n = 13, mean age 33 ± 10 years). In the BAV-patients, aortic root diameter was 35.1 ± 4.9 mm versus 28.9 ± 4.8 mm in the control group (p < 0.01). The diameter of the ascending aorta was also significantly increased at the level of the pulmonary artery (35.5 ± 5.6 mm versus 27.0 ± 4.8 mm, p < 0.001). BAV-patients with moderate or severe aortic regurgitation (n = 18, mean age 32 ± 9 years, n.s. versus control) had a significant dilatation of the aortic root, ascending aorta at the level of the pulmonary artery (41.7 ± 4.8 mm versus 27.0 ± 4.8 mm in control patients, p < 0.001) and, furthermore, significantly increased diameters of the aortic arch (27.1 ± 5.6 mm versus 21.5 ± 1.8 mm, p < 0.01) and descending aorta (21.8 ± 5.6 mm versus 17.0 ± 5.6 mm, p < 0.01). Conclusions: The whole thoracic aorta is abnormally dilated in patients with BAV, particularly in patients with moderate/severe aortic regurgitation. The maximum dilatation occurs in the ascending aorta at the level of the pulmonary artery. Thus, we suggest evaluation of the entire thoracic aorta in patients with BAV.


2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Alejandro Perez-Casares ◽  
Audrey Dionne ◽  
Kimberlee Gauvreau ◽  
Ashwin Prakash

Abstract Background Aortic stiffness has been shown to be abnormal in patients with bicuspid aortic valve (BAV), and is considered a component of the aortopathy associated with this condition. Progressive aortic stiffening associated with aging has been previously described in normal adults. However, it is not known if aging related aortic stiffening occurs at the same rate in BAV patients. We determined the longitudinal rate of decline in segmental distensibility in BAV patients using serial cardiovascular magnetic resonance (CMR) studies, and compared to previously published results from a group of patients with connective tissue disorders (CTD). Methods A retrospective review of CMR and clinical data on children and adults with BAV (n = 49, 73% male; 23 ± 11 years) with at least two CMRs (total 98 examinations) over a median follow-up of 4.1 years (range 1–9 years) was performed to measure aortic distensibility at the ascending (AAo) and descending aorta (DAo). Longitudinal changes in aortic stiffness were assessed using linear mixed-effects modeling. The comparison group of CTD patients had a similar age and gender profile (n = 50, 64% male; 20.6 ± 12 years). Results Compared to CTD patients, BAV patients had a more distensible AAo early in life but showed a steeper decline in distensibility on serial examinations [mean 10-year decline in AAo distensibility (× 10−3 mmHg−1) 2.4 in BAV vs 1.3 in CTD, p = 0.005]. In contrast, the DAo was more distensible in BAV patients throughout the age spectrum, and DAo distensibility declined with aging at a rate similar to CTD patients [mean 10 year decline in DAo distensibility (× 10−3 mmHg−1) 0.3 in BAV vs 0.4 in CTD, p = 0.58]. Conclusions On serial CMR measurements, AAo distensibility declined at significantly steeper rate in BAV patients compared to a comparison group with CTDs, while DAo distensibility declined at similar rates in both groups. These findings offer new mechanistic insights into the differing pathogenesis of the aortopathy seen in BAV and CTD patients.


2021 ◽  
Vol 12 (4) ◽  
pp. 508-515 ◽  
Author(s):  
Yuki Nakayama ◽  
Takeshi Shinkawa ◽  
Goki Matsumura ◽  
Ryogo Hoki ◽  
Kei Kobayashi ◽  
...  

Background: The purpose of this study was to assess autograft function after the Ross procedure and to review surgical outcomes associated with autograft reoperations. Methods: This is a retrospective study of patients undergoing the Ross procedure since 1993. Autograft function and autograft reoperation were studied. Autograft failure was defined as more than moderate autograft regurgitation or autograft dilatation to more than 50 mm diameter or z-score of more than +4 in children. One hospital death was excluded from analysis as were patients with unknown late autograft status. Results: Among 75 patients analyzed, preoperative diagnosis before the Ross procedure included aortic regurgitation in 26, aortic stenosis in 19, combined lesions in 28, and 2 mechanical valve malfunctions. Median age at the Ross procedure was 12.1 (0.4-43.6) years with 44 children less than 15 years old. Six patients had greater than mild autograft regurgitation at post-Ross hospital discharge. During median follow-up of 14.9 years, there were 23 autograft failures. Eighteen autograft reoperations were performed on 17 patients (13 children), including 12 aortic valve replacements, 5 aortic root replacements (including 1 valve-sparing root replacement), and 1 Konno procedure. Freedom from autograft failure and autograft reoperation at 20 years after the Ross procedure was 52.0% and 66.3%, respectively. Multivariate analysis identified greater than mild autograft regurgitation at hospital discharge from Ross procedure as a risk factor for autograft failure ( P < .01). All patients who underwent autograft reoperation survived and had good health status at a median of 6.9 years after the reoperation. Conclusions: The Ross procedure is effective in delaying prosthetic aortic valve replacement, although the time-related risk of autograft failure is a real consideration.


2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Haotian Gu ◽  
Rong Bing ◽  
Calvin Chin ◽  
Lingyun Fang ◽  
Audrey C. White ◽  
...  

Abstract Background First-phase ejection fraction (EF1; the ejection fraction measured during active systole up to the time of maximal aortic flow) measured by transthoracic echocardiography (TTE) is a powerful predictor of outcomes in patients with aortic stenosis. We aimed to assess whether cardiovascular magnetic resonance (CMR) might provide more precise measurements of EF1 than TTE and to examine the correlation of CMR EF1 with measures of fibrosis. Methods In 141 patients with at least mild aortic stenosis, we measured CMR EF1 from a short-axis 3D stack and compared its variability with TTE EF1, and its associations with myocardial fibrosis and clinical outcome (aortic valve replacement (AVR) or death). Results Intra- and inter-observer variation of CMR EF1 (standard deviations of differences within and between observers of 2.3% and 2.5% units respectively) was approximately 50% that of TTE EF1. CMR EF1 was strongly predictive of AVR or death. On multivariable Cox proportional hazards analysis, the hazard ratio for CMR EF1 was 0.93 (95% confidence interval 0.89–0.97, p = 0.001) per % change in EF1 and, apart from aortic valve gradient, CMR EF1 was the only imaging or biochemical measure independently predictive of outcome. Indexed extracellular volume was associated with AVR or death, but not after adjusting for EF1. Conclusions EF1 is a simple robust marker of early left ventricular impairment that can be precisely measured by CMR and predicts outcome in aortic stenosis. Its measurement by CMR is more reproducible than that by TTE and may facilitate left ventricular structure–function analysis.


Sign in / Sign up

Export Citation Format

Share Document