PP20 WIRELESS CAPSULE ENDOSCOPY: IMPLICATIONS ON DIAGNOSIS AND THERAPY IN PAEDIATRIC GASTROINTESTINAL DISEASES

2009 ◽  
Vol 41 ◽  
pp. S211
Author(s):  
S. Pastore ◽  
N. Giurici ◽  
D. Giglia ◽  
G. Di Leo ◽  
S. Martelossi ◽  
...  
Sensors ◽  
2020 ◽  
Vol 20 (6) ◽  
pp. 1617
Author(s):  
Ioannis Intzes ◽  
Hongying Meng ◽  
John Cosmas

Wireless Capsule Endoscopy is a state-of-the-art technology for medical diagnoses of gastrointestinal diseases. The amount of data produced by an endoscopic capsule camera is huge. These vast amounts of data are not practical to be saved internally due to power consumption and the available size. So, this data must be transmitted wirelessly outside the human body for further processing. The data should be compressed and transmitted efficiently in the domain of power consumption. In this paper, a new approach in the design and implementation of a low complexity, multiplier-less compression algorithm is proposed. Statistical analysis of capsule endoscopy images improved the performance of traditional lossless techniques, like Huffman coding and DPCM coding. Furthermore the Huffman implementation based on simple logic gates and without the use of memory tables increases more the speed and reduce the power consumption of the proposed system. Further analysis and comparison with existing state-of-the-art methods proved that the proposed method has better performance.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 132850-132859 ◽  
Author(s):  
Muhammad Attique Khan ◽  
Seifedine Kadry ◽  
Majed Alhaisoni ◽  
Yunyoung Nam ◽  
Yudong Zhang ◽  
...  

2021 ◽  
Vol 297 ◽  
pp. 01060
Author(s):  
Said Charfi ◽  
Mohamed El Ansari ◽  
Ayoub Ellahyani ◽  
Ilyas El Jaafari

Wireless capsule endoscopy (WCE) is a novel imaging technique that can view the entire small bowel in human body. Thus, it is presented as an excellent diagnostic tool for evaluation of gastrointestinal diseases compared with traditional endoscopies. However, the diagnosis by the physicians is tedious since it requires reviewing the video extracted from the capsule and analysing all of its frames. This tedious task has encouraged the researchers to provide automated diagnostic technics for WCE frameworks to detect symptoms of gastrointestinal illness. In this paper, we present the prelimenary results of red lesion detection in WCE images using Dense-Unet deep learning segmentation model. To this end, we have used a dataset containing two subsets of anonymized video capsule endoscopy images with annotated red lesions. The first set, used in this work, has 3,295 non-sequential frames and their corresponding annotated masks. The results obtained by the proposed scheme are promising.


2022 ◽  
Vol 3 (1) ◽  
pp. 1-19
Author(s):  
Feng Lu ◽  
Wei Li ◽  
Song Lin ◽  
Chengwangli Peng ◽  
Zhiyong Wang ◽  
...  

Wireless capsule endoscopy is a modern non-invasive Internet of Medical Imaging Things that has been increasingly used in gastrointestinal tract examination. With about one gigabyte image data generated for a patient in each examination, automatic lesion detection is highly desirable to improve the efficiency of the diagnosis process and mitigate human errors. Despite many approaches for lesion detection have been proposed, they mainly focus on large lesions and are not directly applicable to tiny lesions due to the limitations of feature representation. As bleeding lesions are a common symptom in most serious gastrointestinal diseases, detecting tiny bleeding lesions is extremely important for early diagnosis of those diseases, which is highly relevant to the survival, treatment, and expenses of patients. In this article, a method is proposed to extract and fuse multi-scale deep features for detecting and locating both large and tiny lesions. A feature extracting network is first used as our backbone network to extract the basic features from wireless capsule endoscopy images, and then at each layer multiple regions could be identified as potential lesions. As a result, the features maps of those potential lesions are obtained at each level and fused in a top-down manner to the fully connected layer for producing final detection results. Our proposed method has been evaluated on a clinical dataset that contains 20,000 wireless capsule endoscopy images with clinical annotation. Experimental results demonstrate that our method can achieve 98.9% prediction accuracy and 93.5% score, which has a significant performance improvement of up to 31.69% and 22.12% in terms of recall rate and score, respectively, when compared to the state-of-the-art approaches for both large and tiny bleeding lesions. Moreover, our model also has the highest AP and the best medical diagnosis performance compared to state-of-the-art multi-scale models.


Endoscopy ◽  
2006 ◽  
Vol 38 (11) ◽  
Author(s):  
P McConville ◽  
WJ Cash ◽  
RGP Watson ◽  
JS Collins

2017 ◽  
Vol 26 (2) ◽  
pp. 151-156
Author(s):  
Manuele Furnari ◽  
Andrea Buda ◽  
Gabriele Delconte ◽  
Davide Citterio ◽  
Theodor Voiosu ◽  
...  

Background & Aims: Neuroendocrine tumors (NETs) are a heterogeneous group of neoplasms with unclear etiology that may show functioning or non-functioning features. Primary tumor localization often requires integrated imaging. The European Neuroendocrine Tumors Society (ENETS) guidelines proposed wireless-capsule endoscopy (WCE) as a possible diagnostic tool for NETs, if intestinal origin is suspected. However, its impact on therapeutic management is debated. We aimed to evaluate the yield of WCE in detecting intestinal primary tumor in patients showing liver NET metastases when first-line investigations are inconclusive.Method: Twenty-four patients with histological diagnosis of metastatic NET from liver biopsy and no evidence of primary lesions at first-line investigations were prospectively studied in an ENETS-certified tertiary care center. Wireless-capsule endoscopy was requested before explorative laparotomy and intra-operative ultrasound. The diagnostic yield of WCE was compared to the surgical exploration.Results: Sixteen subjects underwent surgery; 11/16 had positive WCE identifying 16 bulging lesions. Mini-laparotomy found 13 NETs in 11/16 patients (9 small bowel, 3 pancreas, 1 bile ducts). Agreement between WCE and laparotomy was recorded in 9 patients (Sensitivity=75%; Specificity=37.5%; PPV=55%; NPV=60%). Correspondence assessed per-lesions produced similar results (Sensitivity=70%; Specificity=25%; PPV=44%; NPV=50%). No capsule retentions were recorded.Conclusions: Wireless-capsule endoscopy is not indicated as second-line investigation for patients with gastro-entero-pancreatic NETs. In the setting of a referral center, it might provide additional information when conventional investigations are inconclusive about the primary site.Abbreviations: DBE: double balloon enteroscopy; GEP-NET: gastro-entero-pancreatic neuroendocrine tumor; GI: gastrointestinal; ENETS: European Neuroendocrine Tumor Society; NET: neuroendocrine tumor; SSRS: somatostatin receptor scintigraphy; WCE: wireless capsule endoscopy.


Sign in / Sign up

Export Citation Format

Share Document