Data Acquisition and Handling Unit for a Quantitative Use of Electron Energy Loss Spectroscopy

Author(s):  
P. Trebbia ◽  
P. Ballongue ◽  
C. Colliex

An effective use of electron energy loss spectroscopy for chemical characterization of selected areas in the electron microscope can only be achieved with the development of quantitative measurements capabilities.The experimental assembly, which is sketched in Fig.l, has therefore been carried out. It comprises four main elements.The analytical transmission electron microscope is a conventional microscope fitted with a Castaing and Henry dispersive unit (magnetic prism and electrostatic mirror). Recent modifications include the improvement of the vacuum in the specimen chamber (below 10-6 torr) and the adaptation of a new electrostatic mirror.The detection system, similar to the one described by Hermann et al (1), is located in a separate chamber below the fluorescent screen which visualizes the energy loss spectrum. Variable apertures select the electrons, which have lost an energy AE within an energy window smaller than 1 eV, in front of a surface barrier solid state detector RTC BPY 52 100 S.Q. The saw tooth signal delivered by a charge sensitive preamplifier (decay time of 5.10-5 S) is amplified, shaped into a gaussian profile through an active filter and counted by a single channel analyser.

2001 ◽  
Vol 7 (S2) ◽  
pp. 1166-1167
Author(s):  
R.D. Leapman ◽  
S.B. Andrews

As techniques for electron energy-loss spectroscopy (EELS) reach a higher degree of optimization, detection limits for analyzing biological structures are approaching those predicted by theory. in favorable specimens, single atom detection is predicted for elemental maps acquired by means of the scanning transmission electron microscope (STEM) equipped with a field emission source, paralleldetection EELS and a spectrum-imaging system. to obtain such results, the electron detector should have a detective quantum efficiency close to unity and a well behaved point-spread function; such design features are now available with a cooled charge-couple device (CCD) array. The energy-filtering transmission electron microscope (EFTEM) provides a complementary approach to mapping elements occurring at higher concentrations but distributed over larger regions of the specimen. Use of an optimized CCD detector in the EFTEM now enables accurate quantitation in addition to high analytical sensitivity, albeit not at the single atom level.


Sign in / Sign up

Export Citation Format

Share Document