Early presentation of endomyocardial fibrosis in a 22-month-old child: a case report

2010 ◽  
Vol 21 (1) ◽  
pp. 101-103 ◽  
Author(s):  
Antoinette M. Cilliers ◽  
Paul E. Adams ◽  
Ana O. Mocumbi

AbstractWe present an unusual, biopsy-proven case of endomyocardial fibrosis in a 22-month-old male child, which progressed rapidly resulting in death. The patient was born to a father originating from Mozambique, where the disease is endemic but who had not himself travelled there, suggesting a genetic link. Other remarkable features were the presence of a right ventricular diverticulum, and a positive Mycoplasma pneumoniae immunoglobulin M enzyme-linked immunosorbent assay test.

Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 353
Author(s):  
Ha Eun Jeon ◽  
Hyun Mi Kang ◽  
Eun Ae Yang ◽  
Hye Young Han ◽  
Seung Beom Han ◽  
...  

The aim of the present study is to re-evaluate the clinical application of two-times serologic immunoglobulin M (IgM) tests using microparticle agglutination assay (MAA), an enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR) assay in diagnosing Mycoplasma pneumoniae (MP) infection. A retrospective analysis of 62 children with MP pneumonia during a recent epidemic (2019–2020) was conducted. The MAA and ELISA immunoglobulin M (IgM) and IgG measurements were conducted twice at admission and around discharge, and MP PCR once at presentation. Diagnostic rates in each test were calculated at presentation and at discharge. The seroconverters were 39% (24/62) of patients tested by MAA and 29% (18/62) by ELISA. At presentation, the diagnostic positive rates of MAA, ELISA, and PCR tests were 61%, 71%, and 52%, respectively. After the second examination, the rates were 100% in both serologic tests. There were positive correlations between the titers of MAA and the IgM values of ELISA. The single serologic IgM or PCR tests had limitations to select patients infected with MP in the early stage. The short-term, paired IgM serologic tests during hospitalization can reduce patient-selection bias in MP infection studies.


2006 ◽  
Vol 13 (10) ◽  
pp. 1166-1169 ◽  
Author(s):  
Stuart D. Blacksell ◽  
Lee Smythe ◽  
Rattanaphone Phetsouvanh ◽  
Michael Dohnt ◽  
Rudy Hartskeerl ◽  
...  

ABSTRACT The diagnostic utility of immunochromatographic (Leptotek) and enzyme-linked immunosorbent assay (ELISA; Panbio) tests for the detection of Leptospira immunoglobulin M antibodies was assessed in febrile adults admitted in Vientiane, Laos. Both tests demonstrated poor diagnostic accuracy using admission serum (Leptotek sensitivity of 47.3% and specificity of 75.5%: ELISA sensitivity of 60.9% and specificity of 65.6%) compared to the Leptospira “gold standard” microscopic agglutination test.


2014 ◽  
Vol 8 (1) ◽  
Author(s):  
Matthew Bunte ◽  
Kenneth Liao ◽  
J Carlos Manivel ◽  
Emil Missov

2003 ◽  
Vol 10 (3) ◽  
pp. 439-442 ◽  
Author(s):  
F. Roodbari ◽  
M. H. Roustai ◽  
A. Mostafaie ◽  
H. Soleimanjdahi ◽  
R. Sarrami Foroshani ◽  
...  

ABSTRACT Measles is a highly contagious respiratory virus infection, with typical clinical symptoms including maculopapular rash, fever, cough, coryza, and conjunctivitis. Despite implementation of widespread vaccination programs throughout the world, the rates of global morbidity and mortality are still considerable. This study was performed to design a reliable indirect enzyme-linked immunosorbent assay (ELISA) to measure measles-specific immunoglobulin M (IgM). First, human IgM was purified, and then an anti-IgM antibody was produced in rabbits and purified in a multistep process. The rabbit IgG against human IgM was conjugated with peroxidase. Measles virus-infected Vero cells produced viral antigen. One hundred serum samples from infants of 9 to 18 months of age, mostly vaccinated, were evaluated for determining the presence of specific IgM antibodies against measles virus. The samples were also evaluated for neutralizing antibodies against measles virus by a microneutralization test (MNT). By comparing the results of the ELISA with those of MNT, it was demonstrated that ELISA had a sensitivity and specificity of 100 and 92%, respectively. On the other hand, when the results obtained by our ELISA system were compared with those of an imported measles virus IgM ELISA kit (EIAgen; Adaltis Italia SPa, Bologna, Italy), a high level of agreement was shown (k = 0.926).


Sign in / Sign up

Export Citation Format

Share Document